{"product_id":"abb-3bdh000011-sa-801f-freelance-power-supply-module","title":"ABB 3BDH000011 SA 801F Freelance Power Supply Module","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe \u003cstrong\u003eSA 801F\u003c\/strong\u003e \u003cstrong\u003e(3BDH000011 ) \u003c\/strong\u003efunctions as a dedicated system component providing stable DC operating voltages directly to electronic assemblies within the ABB Freelance distributed control system platform. Operating on alternative mains configurations, this \u003cstrong\u003epower supply module\u003c\/strong\u003e coordinates vital system energy infrastructure, stepping down high-voltage utility grids into managed currents suitable for backplane instrumentation processing.\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe unit interfaces seamlessly into central rack systems, implementing reliable power filtration profiles to suppress grid fluctuations, voltage spikes, and electromagnetic line anomalies. Its rugged technical design balances standard field distribution configurations with comprehensive short-circuit management and overload protection logic, sustaining continuous operation across diverse industrial process environments.\u003c\/p\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eUniversal Dual Input Matrix\u003c\/strong\u003e: Supports standard alternative main configurations accommodating both 115V AC and 230V AC grid infrastructures\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eSystem-Level Energy Continuity\u003c\/strong\u003e: Delivers fully conditioned output voltage profiles directly to critical backplane communication frameworks.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eOvercurrent Protection\u003c\/strong\u003e: Integrates automated electrical protection barriers to safeguard secondary-side control modules from unpredictable line stress conditions.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eDirect Freelance Integration\u003c\/strong\u003e: Designed for immediate mechanical alignment within standardized system housing chassis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003eDistributed control system backplane electrification across chemical and refining plants.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003eCore power management setups within municipal water treatment facilities.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003eAuxiliary automation supply loops inside food and beverage packaging machinery lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eOrdering Information\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003e3BDH000011-REF\u003c\/strong\u003e: Refurbished SA 801F, Power Supply 115\/230 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n\u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct ID (Ordering Number)\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e3BDH000011-REF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eABB Type Designation\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eSA 801F (SA801F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003ePower Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e115\/230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003ePower_Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePart Type\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eRefurbished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eMalta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e85044030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMade To Order\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMinimum Order Quantity\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSelling Unit of Measure\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003epiece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStocked At (Warehouses)\u003c\/td\u003e\n\u003ctd style=\"padding: 0.5rem;\"\u003eRatingen, Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003ePrimary Mains Isolation\u003c\/strong\u003e: Disconnect all active power grids before performing any maintenance or insertion steps on the chassis layout. Ensure line isolation protocols are verified via active field measurement.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eVoltage Selection Verification\u003c\/strong\u003e: Confirm that the internal auto-sensing loops or terminal jumper positions accurately match your local 115V AC or 230V AC utility profile prior to introducing operational line power.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eRack Alignment and Locking\u003c\/strong\u003e: Slide the module squarely into its designated slot within the Freelance system cabinet frame. Secure all mechanical fasteners or locking levers completely to establish unified ground integrity through the metallic housing tracks.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eThermal Management\u003c\/strong\u003e: Maintain clear clearance limits above and below the supply chassis structure to permit non-obstructed convective cross-ventilation, preventing localized thermal stress within sealed enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668622569835,"sku":"3BDH000011R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-sa801f-3bdh000011r1-power-supply-115-230-vac-ilssqlmpumu_e62a4f12-d34c-45f7-a087-414d6d31052f.jpg?v=1765535862","url":"https:\/\/www.plcprotech.com\/products\/abb-3bdh000011-sa-801f-freelance-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}