{"product_id":"abb-3bhb030310r0001-5shy-4045l0006-pcs6000-igct-module","title":"ABB 3BHB030310R0001 5SHY 4045L0006 PCS6000 IGCT Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 3BHB030310R0001 5SHY 4045L0006\u003c\/strong\u003e is an Integrated Gate-Commutated Thyristor (\u003cstrong\u003eIGCT\u003c\/strong\u003e) semiconductor module engineered for press-pack stack mounting within \u003cstrong\u003eABB PCS6000\u003c\/strong\u003e medium-voltage drive architectures. It serves as a core switching element in phase power modules (\u003cstrong\u003ePOU\u003c\/strong\u003e) and drive line units (\u003cstrong\u003eDLU\u003c\/strong\u003e), executing high-efficiency power conversion in demanding heavy-industrial applications. The \u003cstrong\u003eIGCT Module\u003c\/strong\u003e combines a high-voltage semiconductor switch with an integrated gate driver board, interfaced via fiber-optic connections to ensure complete electrical isolation and high electromagnetic immunity. Utilized within liquid-cooled semiconductor stack assemblies, this device supports stable switching performance in wind power generation, shore-to-ship power conversion, and medium-voltage motor control systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated gate driver board connected via fiber-optic cables for interference-free switching control.\u003c\/li\u003e\n\u003cli\u003eDesigned for press-pack liquid-cooled heat sink assemblies within \u003cstrong\u003ePCS6000\u003c\/strong\u003e power modules.\u003c\/li\u003e\n\u003cli\u003eDirectly compatible with \u003cstrong\u003eFADEC 3\u003c\/strong\u003e semiconductor inspection tools for gate-cathode and state testing.\u003c\/li\u003e\n\u003cli\u003ePrecision-engineered press-pack structure optimized for thermal dissipation under uniform clamping torque.\u003c\/li\u003e\n\u003cli\u003eEssential switching component for medium-voltage system drive converters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eABB PCS6000\u003c\/strong\u003e medium-voltage system drives\u003c\/li\u003e\n\u003cli\u003eWind turbine power converter systems\u003c\/li\u003e\n\u003cli\u003eShore-to-ship static frequency converters\u003c\/li\u003e\n\u003cli\u003eMedium-voltage industrial drive systems and power conversion units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BHB030310R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABB Type Designation\u003c\/td\u003e\n\u003ctd\u003e4500V, 91mm, 5SHY 4045L0006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIGCT MODULE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e4500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWafer Diameter\u003c\/td\u003e\n\u003ctd\u003e91mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States \/ Czech Republic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number (HS Code)\u003c\/td\u003e\n\u003ctd\u003e85413000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUNSPSC\u003c\/td\u003e\n\u003ctd\u003e32111700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport Control Classification\u003c\/td\u003e\n\u003ctd\u003eDual-use item (ECN 3A001g2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplaces Product ID (OLD)\u003c\/td\u003e\n\u003ctd\u003e3BHB020720R0002, 3BHL000986P3105, 3BHB013085R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCS6000 System Drives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Gate-Commutated Thyristor (IGCT) Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Signal Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFiber-optic cable interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid-cooled press-pack stack assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostic Device Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFADEC 3 Semiconductor Tester (3BHE043725R0001)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Tooling Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter Service Toolbox (3BHB008753R0002)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector \/ Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Optic Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransmits gate control signals between the main controller\/PECINT board and the gate unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGate-Cathode Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal driver interface to the semiconductor pole piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIPS Power Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary power supply connection for the integrated gate unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Isolation\u003c\/strong\u003e: Fully de-energize the drive system and follow the standard 7 steps that save lives. Ensure all main power, external control voltages, and auxiliary supplies are isolated and tagged out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding \u0026amp; ESD Precautions\u003c\/strong\u003e: Connect the grounding kit (3BHE039277R0001) to phase and PE connections prior to touching internal components. Wear appropriate ESD protection when handling gate unit circuit boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling System Preparation\u003c\/strong\u003e: Depressurize and drain the liquid cooling circuit before releasing semiconductor stack pressure to prevent coolant spills inside the cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStack Release\u003c\/strong\u003e: Install stabilizer plates into the power module framework. Loosen clamping bolts in the specified order and apply the mechanical spreading tool (3BHE041414R0001) over the heat sinks to open the stack gap.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Handling\u003c\/strong\u003e: Disconnect fiber-optic cables and auxiliary wiring. Unbolt gate unit fixations and carefully extract the IGCT module without applying mechanical force to the gate board or pole surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping \u0026amp; Alignment\u003c\/strong\u003e: Ensure heat sinks and pole pieces are properly centered during reassembly. Relieve the spreading tool and tighten clamping bolts using calibrated pressure loading gauges to achieve accurate contact force.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eANSI Z535.6\u003c\/li\u003e\n\u003cli\u003eISO 7010 \/ ISO 3864-2\u003c\/li\u003e\n\u003cli\u003eEN 50110 (Electrical Work Safety)\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668530721131,"sku":"3BHB030310R0001 5SHY 4045L0006","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-3bhb030310r0001-5shy4045l0006-igct-module-fiq1ugbulo0_8d6a60ec-f1a0-4d09-ac51-61401bcb9fd3.jpg?v=1765532898","url":"https:\/\/www.plcprotech.com\/products\/abb-3bhb030310r0001-5shy-4045l0006-pcs6000-igct-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}