{"product_id":"abb-3bse013224r1-ci810v2-advant-s800-i-o-af100-communication-interface","title":"ABB 3BSE013224R1 CI810V2 Advant S800 I\/O AF100 Communication Interface","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eIntegrating seamless Advant Fieldbus 100 connectivity into distributed control architectures, the \u003cstrong\u003eABB 3BSE013224R1 CI810V2\u003c\/strong\u003e functions as a high-speed communication interface for S800 I\/O modules. This field communication interface acts as the local link master, managing exchange rates and diagnostic reporting between connected I\/O clusters and upper-level Advant Controllers (such as AC 800M or AC 450). It delivers reliable cyclic data transmission and supports redundant configurations to maximize process uptime in heavy industrial automation systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eProvides physical and logical connection to the Advant Fieldbus 100 (AF100) twisted-pair network.\u003c\/li\u003e\n  \u003cli\u003eSupports up to 12 S800 I\/O modules per cluster, handling both digital and analog signal types.\u003c\/li\u003e\n  \u003cli\u003eEquipped with comprehensive LED diagnostics on the front face for run, fail, and traffic status monitoring.\u003c\/li\u003e\n  \u003cli\u003eSupports hot-swap operation (Hot Configuration in Run) when paired with compatible module termination units.\u003c\/li\u003e\n  \u003cli\u003eOptoelectronic galvanic isolation ensures high electromagnetic compatibility (EMC) and protects internal logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eDistributed Control Systems (DCS) in oil, gas, and petrochemical facilities.\u003c\/li\u003e\n  \u003cli\u003ePower generation and turbine control systems requiring deterministic process bus communication.\u003c\/li\u003e\n  \u003cli\u003ePulp and paper mill processing lines with dense, localized analog and digital I\/O clusters.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater plant control upgrades running legacy Advant S800 I\/O networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCI810V2\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eArticle Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3BSE013224R1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProtocol Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAdvant Fieldbus 100 (AF100)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupported I\/O System\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eS800 I\/O Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNominal Supply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24 V DC (limits 19.2 V DC to 30 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCurrent Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e100 mA typical at 24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eIsolation Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e50 V (galvanic isolation to I\/O backplane)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to +55 degC (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSweden\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.35 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e25.0 x 12.0 x 10.0 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe CI810V2 directly replaces older legacy revisions (such as CI810V1) within existing S800 structures. When upgrading, ensure the system controller's system software\/firmware supports the newer V2 module revision. While form-factor compatible, failing to align controller-side hardware configuration files can prevent module identification on the AF100 bus.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAvoid running signal cables and the AF100 bus lines in the same wire ducts as high-power AC lines to prevent magnetic coupling. In high-temperature panels exceeding 45 degC, verify active air circulation, as the thermal build-up inside tightly enclosed clusters can degrade optical link stability when fiber-optic modems are coupled to the bus.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways double-check that both termination resistors are in place at the physical ends of the AF100 bus network. An un-terminated or double-terminated bus leads to high reflection coefficients and diagnostic errors. Ensure that the module is completely clicked into its slot on the Module Termination Unit (MTU) before securing the screw terminals.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate and lock out all 24 V DC system power sources before performing physical replacement or wiring on the communication module backplane. Working on an active system can cause transient bus faults, halting down-stream process controllers.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eConfigure the station address on the Module Termination Unit (MTU) rotary switches prior to slotting the CI810V2 interface module.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eAlign the module guides with the slots on the MTU and push firmly until the locking mechanisms click securely into place.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eTerminate the AF100 twisted pair cable shield to the grounding rail using low-impedance ground clamps to prevent electromagnetic interference.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eRestore 24 V DC power and verify that the \"RUN\" LED lights steady green, confirming that system initialization is successful.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701957390699,"sku":"3BSE013224R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse013224r1-2g2zfn5xxly_d85d59c4-674d-4fd8-ac57-c96c0817db42.jpg?v=1766478120","url":"https:\/\/www.plcprotech.com\/products\/abb-3bse013224r1-ci810v2-advant-s800-i-o-af100-communication-interface","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}