{"product_id":"abb-3bse018144r1-ci857k01-insum-ethernet-interface","title":"ABB 3BSE018144R1 CI857K01 INSUM Ethernet Interface","description":"\u003ch3 data-section-id=\"1n8lizy\" data-start=\"69\" data-end=\"89\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"90\" data-end=\"396\"\u003e\u003cstrong data-start=\"90\" data-end=\"117\"\u003eCI857K01 (3BSE018144R1)\u003c\/strong\u003e is an ABB AC 800M INSUM Ethernet Interface module designed for industrial communication between control systems and switchgear networks. It operates inside ABB 800xA and AC 800M architectures and supports reliable Ethernet-based data exchange for distributed automation systems.\u003c\/p\u003e\n\u003cp data-start=\"398\" data-end=\"694\"\u003eThis module is widely used in power generation plants, oil refineries, and heavy process industries where stable communication between controllers and motor control centers is critical. It reduces downtime by maintaining deterministic INSUM network communication under continuous load conditions.\u003c\/p\u003e\n\u003cp data-start=\"696\" data-end=\"982\"\u003eEngineers deploy this interface to connect control processors with intelligent switchgear systems. It ensures consistent signal transmission in high-interference electrical environments. The module supports long lifecycle operation in both legacy and modern ABB control infrastructures.\u003c\/p\u003e\n\u003ch3 data-section-id=\"waziit\" data-start=\"984\" data-end=\"1030\"\u003eCommunication Architecture \u0026amp; Configuration\u003c\/h3\u003e\n\u003cp data-start=\"1031\" data-end=\"1155\"\u003eThe CI857K01 module combines a CI857 communication interface with a TP853 baseplate for direct rack mounting in ABB systems.\u003c\/p\u003e\n\u003cp data-start=\"1157\" data-end=\"1441\"\u003eIt functions as an Ethernet gateway for INSUM communication, enabling real-time interaction between AC 800M controllers and distributed motor control systems. The module does not execute control logic but handles structured data exchange between field devices and central controllers.\u003c\/p\u003e\n\u003cp data-start=\"1443\" data-end=\"1654\"\u003eThe architecture supports scalable system expansion without additional protocol converters. It integrates natively into ABB 800xA environments and maintains stable performance in continuous industrial operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1656\" data-end=\"1684\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1686\" data-end=\"2058\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1686\" data-end=\"1710\"\u003e\n\u003ctr data-start=\"1686\" data-end=\"1710\"\u003e\n\u003cth data-start=\"1686\" data-end=\"1693\" data-col-size=\"sm\" class=\"\"\u003eItem\u003c\/th\u003e\n\u003cth data-start=\"1693\" data-end=\"1710\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1735\" data-end=\"2058\"\u003e\n\u003ctr data-start=\"1735\" data-end=\"1755\"\u003e\n\u003ctd data-start=\"1735\" data-end=\"1743\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"1743\" data-end=\"1755\" data-col-size=\"sm\"\u003eCI857K01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1756\" data-end=\"1785\"\u003e\n\u003ctd data-start=\"1756\" data-end=\"1769\" data-col-size=\"sm\"\u003eOrder Code\u003c\/td\u003e\n\u003ctd data-start=\"1769\" data-end=\"1785\" data-col-size=\"sm\"\u003e3BSE018144R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1786\" data-end=\"1801\"\u003e\n\u003ctd data-start=\"1786\" data-end=\"1794\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1794\" data-end=\"1801\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1802\" data-end=\"1821\"\u003e\n\u003ctd data-start=\"1802\" data-end=\"1811\" data-col-size=\"sm\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-start=\"1811\" data-end=\"1821\" data-col-size=\"sm\"\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1822\" data-end=\"1861\"\u003e\n\u003ctd data-start=\"1822\" data-end=\"1837\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1837\" data-end=\"1861\"\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1862\" data-end=\"1881\"\u003e\n\u003ctd data-start=\"1862\" data-end=\"1871\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"1871\" data-end=\"1881\" data-col-size=\"sm\"\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1882\" data-end=\"1918\"\u003e\n\u003ctd data-start=\"1882\" data-end=\"1895\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"1895\" data-end=\"1918\" data-col-size=\"sm\"\u003e127.5 x 186 x 59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1919\" data-end=\"1953\"\u003e\n\u003ctd data-start=\"1919\" data-end=\"1936\" data-col-size=\"sm\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-start=\"1936\" data-end=\"1953\" data-col-size=\"sm\"\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1954\" data-end=\"1993\"\u003e\n\u003ctd data-start=\"1954\" data-end=\"1974\" data-col-size=\"sm\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-start=\"1974\" data-end=\"1993\" data-col-size=\"sm\"\u003e\u0026lt; 5 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1994\" data-end=\"2027\"\u003e\n\u003ctd data-start=\"1994\" data-end=\"2009\" data-col-size=\"sm\"\u003eNetwork Type\u003c\/td\u003e\n\u003ctd data-start=\"2009\" data-end=\"2027\" data-col-size=\"sm\"\u003eINSUM Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2028\" data-end=\"2058\"\u003e\n\u003ctd data-start=\"2028\" data-end=\"2039\" data-col-size=\"sm\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2039\" data-end=\"2058\"\u003eTP853 Baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-section-id=\"1uce968\" data-start=\"2060\" data-end=\"2078\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp data-start=\"2080\" data-end=\"2215\"\u003e\u003cstrong data-start=\"2080\" data-end=\"2121\"\u003eIs 3BSE018144R1 the same as CI857K01?\u003c\/strong\u003e\u003cbr data-start=\"2121\" data-end=\"2124\"\u003eYes. 3BSE018144R1 is the ABB order code, while CI857K01 is the functional type designation.\u003c\/p\u003e\n\u003cp data-start=\"2217\" data-end=\"2346\"\u003e\u003cstrong data-start=\"2217\" data-end=\"2262\"\u003eWhere is this module typically installed?\u003c\/strong\u003e\u003cbr data-start=\"2262\" data-end=\"2265\"\u003eIt is installed in ABB AC 800M or 800xA control cabinets for INSUM communication.\u003c\/p\u003e\n\u003cp data-start=\"2348\" data-end=\"2468\"\u003e\u003cstrong data-start=\"2348\" data-end=\"2387\"\u003eIs CI857K01 still supported by ABB?\u003c\/strong\u003e\u003cbr data-start=\"2387\" data-end=\"2390\"\u003eThe module is marked obsolete but still widely used in installed base systems.\u003c\/p\u003e\n\u003cp data-start=\"2470\" data-end=\"2620\"\u003e\u003cstrong data-start=\"2470\" data-end=\"2521\"\u003eCan it integrate with modern Ethernet networks?\u003c\/strong\u003e\u003cbr data-start=\"2521\" data-end=\"2524\"\u003eYes, it operates within ABB INSUM Ethernet architecture but is not a general IT Ethernet device.\u003c\/p\u003e\n\u003ch3\u003eEngineering Installation Key Points\u003c\/h3\u003e\n\u003cp\u003eInstallation of CI857K01 (3BSE018144R1) requires strict control of grounding, signal integrity, and module seating quality. Improper handling will directly cause INSUM communication instability or intermittent bus faults.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Baseplate Seating Integrity\u003c\/strong\u003e\u003cbr\u003eEnsure TP853 baseplate is fully locked into the AC 800M rack. Partial engagement leads to unstable backplane communication and random module dropout under load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Signal Grounding Discipline\u003c\/strong\u003e\u003cbr\u003eApply single-point grounding for Ethernet shield. Do not connect both ends of shield to cabinet ground. Multi-point grounding introduces loop current and distorts INSUM signal transmission.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Cable Routing Separation\u003c\/strong\u003e\u003cbr\u003eKeep INSUM Ethernet cables physically separated from motor power cables and VFD output lines. Minimum separation distance should be maintained inside the cabinet to reduce electromagnetic coupling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Insertion Alignment Control\u003c\/strong\u003e\u003cbr\u003eInstall CI857 module only after confirming perfect alignment with baseplate connectors. Forceful insertion under misalignment condition will damage backplane pins.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Thermal \u0026amp; Vibration Awareness\u003c\/strong\u003e\u003cbr\u003eAvoid placing module near high-heat power supplies or high-vibration zones such as transformer compartments. Long-term exposure accelerates connector fatigue and communication errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. Commissioning Check\u003c\/strong\u003e\u003cbr\u003eAfter installation, verify Ethernet link stability and INSUM node recognition in controller diagnostics before bringing system online. Do not skip pre-energization validation.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701958308203,"sku":"3BSE018144R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse018144r1-lg5tbya3u0e_4c6a5e99-5982-457f-a7c4-f75273ffac84.jpg?v=1766478149","url":"https:\/\/www.plcprotech.com\/products\/abb-3bse018144r1-ci857k01-insum-ethernet-interface","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}