{"product_id":"abb-3bse024388r1-pfxa-401-control-unit","title":"ABB 3BSE024388R1 PFXA 401 Control unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 3BSE024388R1 PFXA 401\u003c\/strong\u003e is a control unit used in ABB force measurement, strip tension, and strip position measurement systems.\u003c\/p\u003e\n\u003cp\u003eThe PFXA 401 provides \u003cstrong\u003etwo analog inputs\u003c\/strong\u003e and supports angle compensation for compatible ABB load cells. ABB documents compatibility with QGPR 102\/104 load cells up to 2 MN and PFBL 101\/141 load cells up to 2 x 400 kN.\u003c\/p\u003e\n\u003cp\u003eThe control unit can also interface with two PMSG 123 or PMSG 125 edge sensors. This allows the PFXA 401 to participate in strip width and position measurement applications as well as force and tension measurement systems.\u003c\/p\u003e\n\u003cp\u003eThe unit incorporates dedicated mains, synchronization, analog output, digital signal, and sensor connection terminals. Its ABB product record also identifies an internal lithium battery and a 2 A, 250 V fuse.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eABB PFXA 401 control unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct ID 3BSE024388R1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo analog inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAngle compensation for supported load-cell configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with QGPR 102\/104 load cells up to 2 MN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with PFBL 101\/141 load cells up to 2 x 400 kN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterface capability for two PMSG 123 or PMSG 125 edge sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDedicated analog output connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDedicated digital signal connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMains and synchronization terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplaceable lithium battery identified by ABB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 A, 250 V fuse identified by ABB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUsed in ABB force, tension, and strip position measurement systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eStrip and web tension measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoll force measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrip width and position measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoad-cell signal processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEdge sensor integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance of ABB PFXA401 electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement of existing 3BSE024388R1 control units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE024388R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType Designation\u003c\/td\u003e\n\u003ctd\u003ePFXA 401\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eControl Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQGPR Load Cell Compatibility\u003c\/td\u003e\n\u003ctd\u003eQGPR 102 \/ 104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum QGPR Load\u003c\/td\u003e\n\u003ctd\u003e2 MN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePFBL Load Cell Compatibility\u003c\/td\u003e\n\u003ctd\u003ePFBL 101 \/ 141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PFBL Configuration\u003c\/td\u003e\n\u003ctd\u003e2 x 400 kN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEdge Sensor Compatibility\u003c\/td\u003e\n\u003ctd\u003ePMSG 123 \/ 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Edge Sensors\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLithium Battery\u003c\/td\u003e\n\u003ctd\u003e3BSC790006R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse\u003c\/td\u003e\n\u003ctd\u003e2 A, 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Part Number\u003c\/td\u003e\n\u003ctd\u003e3BSC770029R17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003e5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Weight\u003c\/td\u003e\n\u003ctd\u003e5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGross Volume\u003c\/td\u003e\n\u003ctd\u003e8 dm3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Type\u003c\/td\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eX1\u003c\/td\u003e\n\u003ctd\u003eMains connection, 4-pole disconnectable terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX2\u003c\/td\u003e\n\u003ctd\u003eSync, 3-pole disconnectable terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX3 \/ X13 \/ X5 \/ X15\u003c\/td\u003e\n\u003ctd\u003e4-pole disconnectable terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX8 \/ X18 \/ X23 \/ X30\u003c\/td\u003e\n\u003ctd\u003e2-pole disconnectable terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX6 \/ X16\u003c\/td\u003e\n\u003ctd\u003eAnalog output, 6-pole disconnectable terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX24 \/ X25 \/ X34 \/ X35\u003c\/td\u003e\n\u003ctd\u003eDigital signal, 5-pole disconnectable terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eComponent References\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eABB Reference\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLithium Battery\u003c\/td\u003e\n\u003ctd\u003e3BSC790006R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse\u003c\/td\u003e\n\u003ctd\u003e3BSC770029R17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX1 Terminal\u003c\/td\u003e\n\u003ctd\u003e2664197-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX2 Terminal\u003c\/td\u003e\n\u003ctd\u003e2664177-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX3 \/ X13 \/ X5 \/ X15 Terminal\u003c\/td\u003e\n\u003ctd\u003e2664177-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX8 \/ X18 \/ X23 \/ X30 Terminal\u003c\/td\u003e\n\u003ctd\u003e2664177-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX6 \/ X16 Analog Output Terminal\u003c\/td\u003e\n\u003ctd\u003e2662177-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX24 \/ X25 \/ X34 \/ X35 Digital Signal Terminal\u003c\/td\u003e\n\u003ctd\u003e2664163-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the complete \u003cstrong\u003e3BSE024388R1 \/ PFXA 401\u003c\/strong\u003e identification before replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecord existing terminal assignments before removing the installed unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the connected load-cell type and measurement range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify whether QGPR, PFBL, or PMSG sensors are used in the existing system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePreserve analog output and digital signal wiring during replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect the battery and fuse condition before commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm sensor readings and angle compensation after installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the associated tension, force, or strip-position measurement function before normal operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplacement Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMatch both Product ID \u003cstrong\u003e3BSE024388R1\u003c\/strong\u003e and type designation \u003cstrong\u003ePFXA 401\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the installed load cells and edge sensors before substitution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePreserve existing measurement and compensation settings where applicable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not assume terminal assignments beyond those explicitly identified in ABB documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53756460859755,"sku":"3BSE024388R1 PFXA401","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/PFXA-401-3BSE024388R1_001_1200x1200_4d513d4c-07a3-41ad-abee-5e0901ee0244.jpg?v=1787461644","url":"https:\/\/www.plcprotech.com\/products\/abb-3bse024388r1-pfxa-401-control-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}