{"product_id":"abb-83sr07-e-r1210-gjr2392700r1210-procontrol-p-control-module","title":"ABB 83SR07-E\/R1210 GJR2392700R1210 PROCONTROL P Control Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 83SR07-E\/R1210 GJR2392700R1210\u003c\/strong\u003e is a stored-program analog control module designed for controlling one or two process variables within the \u003cstrong\u003ePROCONTROL P\u003c\/strong\u003e automation architecture. The \u003cstrong\u003e83SR07-E\/R1210 GJR2392700R1210\u003c\/strong\u003e features two continuous outputs for outputting correcting variables to electrohydraulic actuators, electropneumatic actuators, and electric-motor-powered drives. Equipping two hardware process interfaces, the module operates with fixed cycle times of 100 ms for single-actuator control or 200 ms for two-actuator control. The unit interfaces directly with the station bus via a shared memory structure for data exchange with process operator stations and higher-level automatic control systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModule address is configured automatically upon insertion into the PROCONTROL station slot.\u003c\/li\u003e\n\u003cli\u003eBus telegram transfers are verified using parity bit generation and checking.\u003c\/li\u003e\n\u003cli\u003eUser programs are stored in non-volatile EEPROM and can be loaded or modified via the bus.\u003c\/li\u003e\n\u003cli\u003eIncludes short-circuit-proof internal contact and transducer power supply outputs (UK1, UK2, S11\/S13, S21\/S23).\u003c\/li\u003e\n\u003cli\u003eFeatures front-panel LED indicators for general disturbance (ST) and module disturbance (SG).\u003c\/li\u003e\n\u003cli\u003eMicroprocessor processing section supported by EPROM, EEPROM, and RAM memory areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAnalog control of electrohydraulic and electropneumatic process actuators.\u003c\/li\u003e\n\u003cli\u003eContinuous positioning and drive control for electric-motor-powered actuators.\u003c\/li\u003e\n\u003cli\u003eProcess variable signal conditioning and single-variable or master control loops in power plant automation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eType Designation\u003c\/th\u003e\n\u003cth\u003eOrder Number\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e83SR07-E\/R1210\u003c\/td\u003e\n\u003ctd\u003eGJR2392700R1210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral \u0026amp; Structural\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Dimensions\u003c\/td\u003e\n\u003ctd\u003e6 units, 1 division, 160 mm deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStation Bus Connector\u003c\/td\u003e\n\u003ctd\u003e48-pin edge-connector, type F (Connector X11)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connector\u003c\/td\u003e\n\u003ctd\u003e32-pin edge-connector, type F (Connector X21)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical \/ Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage (USA\/USB)\u003c\/td\u003e\n\u003ctd\u003e19.5 ... 30 V, typ. 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (at 24 V)\u003c\/td\u003e\n\u003ctd\u003e145 mA + output values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation (at 24 V)\u003c\/td\u003e\n\u003ctd\u003e5 ... 8.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Potential (Process Side Z)\u003c\/td\u003e\n\u003ctd\u003e0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Potential (Bus Side ZD)\u003c\/td\u003e\n\u003ctd\u003e0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBinary Inputs \u0026amp; Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Checkback Inputs (EZx, EOx, TSx, STAx)\u003c\/td\u003e\n\u003ctd\u003eDirect connection for 2 process interfaces, 5 mA at 48 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Voltages (UK1, UK2)\u003c\/td\u003e\n\u003ctd\u003e48 V \/ \u0026lt;= 30 mA (short-circuit-proof)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Release Outputs (AFx)\u003c\/td\u003e\n\u003ctd\u003eUS - max. 4 V, Output current \u0026lt;= 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels (Ex1, Ex2, Ex3, Ex4)\u003c\/td\u003e\n\u003ctd\u003eConfigurable for 2-wire or 4-wire transducers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e0 ... 20 mA or 4 ... 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Value\u003c\/td\u003e\n\u003ctd\u003e-1 ... 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Ri)\u003c\/td\u003e\n\u003ctd\u003e50 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (at 23 degC)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (0 to 70 degC, Aging, Voltage)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon-Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e120 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Power Supply (Sx1\/Sx3)\u003c\/td\u003e\n\u003ctd\u003eUS - max. 4 V, Output current \u0026lt;= 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels (AYx\/Zx1)\u003c\/td\u003e\n\u003ctd\u003e0 ... 20 mA or 4 ... 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurden\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 500 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (at 23 degC)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (over Temp., Aging, Voltage)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 0.4 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance \u0026amp; Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInitialization Time\u003c\/td\u003e\n\u003ctd\u003e2 ... 22 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrostatic Discharge Immunity\u003c\/td\u003e\n\u003ctd\u003eDIN EN 61000-4-2: 8 kV \/ 4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiated RF Electromagnetic Field Immunity\u003c\/td\u003e\n\u003ctd\u003eDIN EN 61000-4-3: 10 V\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Fast Transient\/Burst Immunity\u003c\/td\u003e\n\u003ctd\u003eDIN EN 61000-4-4: 2 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Immunity\u003c\/td\u003e\n\u003ctd\u003eDIN EN 61000-4-5: 2 kV \/ 1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConducted Disturbances Immunity\u003c\/td\u003e\n\u003ctd\u003eDIN EN 61000-4-6: 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/z02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 1: Analog output AY1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/b02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 1: Process checkback signal CLOSED EZ1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/z04\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 1: Analog output reference Z11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/b04\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 1: Process checkback signal OPEN EO1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/z06\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 1: Drive release AF1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/b06\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 1: Local intervention TS1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/z08\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 1: Substation disturbance STAx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/b08\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 1: Contact supply UK1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/z10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 1: Analog input E13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/b10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 1: Analog input E11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/z12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 1: Transducer supply S13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/b12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 1: Transducer supply S11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/z14\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 1: Analog input E14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/b14\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 1: Analog input E12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/z16\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 1: Reference Z14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/b16\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 1: Reference Z12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/z18\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 2: Analog output AY2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/b18\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 2: Process checkback signal CLOSED EZ2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/z20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 2: Analog output reference Z21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/b20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 2: Process checkback signal OPEN EO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/z22\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 2: Drive release AF2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/b22\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 2: Local intervention TS2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/z24\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 2: Substation disturbance STA2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/b24\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 2: Contact supply UK2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/z26\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 2: Analog input E23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/b26\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 2: Analog input E21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/z28\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 2: Transducer supply S23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/b28\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 2: Transducer supply S21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/z30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 2: Analog input E24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/b30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 2: Analog input E22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/z32\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 2: Reference Z24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX21\/b32\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess interface 2: Reference Z22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure module slot assignment correctly sets the module address automatically on insertion.\u003c\/li\u003e\n\u003cli\u003eConnect terminal X11\/d18 to bus reference potential ZD once per subrack to ensure proper module functioning.\u003c\/li\u003e\n\u003cli\u003eConfigure hardware jumpers X200 through X203 according to the analog input transducer configuration (plugged in for non-floating 2-wire transducers; removed for floating 2-wire or 4-wire transducers).\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring load requirements do not exceed short-circuit-proof current outputs (100 mA for drive release AFx, 50 mA for transducer supply Sx1\/Sx3, 30 mA for contact supply UKx).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN EN 61000-4-2\u003c\/li\u003e\n\u003cli\u003eDIN EN 61000-4-3\u003c\/li\u003e\n\u003cli\u003eDIN EN 61000-4-4\u003c\/li\u003e\n\u003cli\u003eDIN EN 61000-4-5\u003c\/li\u003e\n\u003cli\u003eDIN EN 61000-4-6\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668496970091,"sku":"GJR2392700R1210 83SR07B-E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-gjr2392700r1210-83sr07b-e-process-control-uh52ueuoopq_40d3c943-f5eb-49c5-9d21-427c4cdc77af.jpg?v=1765532435","url":"https:\/\/www.plcprotech.com\/products\/abb-83sr07-e-r1210-gjr2392700r1210-procontrol-p-control-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}