{"product_id":"abb-8vzz000167h1-do05-16ch-digital-output-w-relay-i-o-module","title":"ABB 8VZZ000167H1 DO05 16CH Digital Output w\/Relay I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 8VZZ000167H1 DO05\u003c\/strong\u003e is a digital output \u003cstrong\u003eI\/O module\u003c\/strong\u003e designed for discrete switching within ABB Symphony Plus and S+ SD I\/O control architectures. Operating as a 16-channel digital output module, it provides isolated signal interface capabilities between the DCS controller and field-level actuators, control relays, solenoids, and indicators.\u003c\/p\u003e\n\u003cp\u003eBuilt around 16 electromechanical relays, the \u003cstrong\u003eABB 8VZZ000167H1 DO05\u003c\/strong\u003e supports configurable Normally Open (NO) or Normally Closed (NC) operation for each channel. The module requires an \u003cstrong\u003exBS02-EPD\u003c\/strong\u003e base unit for mounting and field wiring termination. It handles versatile switching duties across diverse AC and DC voltage ranges, providing physical electrical isolation to protect upper-level process control electronics from field transients.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Independent Channels:\u003c\/strong\u003e Equips systems with 16 discrete digital output relay channels for multi-device process control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectromechanical Switching:\u003c\/strong\u003e Features 16 onboard electromechanical relays supporting selectable NO or NC configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Load Ratings:\u003c\/strong\u003e Handles multiple load profiles including 3 A at 24 V DC, 1 A at 48 V DC, 250 mA at 125 V DC, and 3 A at 120 V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Plate Integration:\u003c\/strong\u003e Connects seamlessly into the dedicated xBS02-EPD base unit for secure mounting and simplified backplane interfacing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Footprint:\u003c\/strong\u003e Engineered in a slim form factor measuring 34 mm in width and weighing 0.295 kg.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eActuator \u0026amp; Solenoid Control:\u003c\/strong\u003e Interfacing discrete control commands to motor starters, solenoid valves, and interlock coils.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Plant Automation:\u003c\/strong\u003e Command signaling for alarms, field annunciators, status indicators, and auxiliary power switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSymphony Plus DCS Expansion:\u003c\/strong\u003e Integrating discrete relay output points into ABB S+ SD I\/O nodes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e8VZZ000167H1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABB Type Designation\u003c\/td\u003e\n\u003ctd\u003eDO05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eI\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl System Platform\u003c\/td\u003e\n\u003ctd\u003eSymphony Plus \/ S+ SD I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired Base Unit\u003c\/td\u003e\n\u003ctd\u003exBS02-EPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e853890\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e85389081\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eOutput Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channel Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output (DO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Type\u003c\/td\u003e\n\u003ctd\u003e16 Electromechanical Relays (NO or NC selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Rating (24 V DC)\u003c\/td\u003e\n\u003ctd\u003e3 A @ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Rating (48 V DC)\u003c\/td\u003e\n\u003ctd\u003e1 A @ 48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Rating (125 V DC)\u003c\/td\u003e\n\u003ctd\u003e250 mA @ 125 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Rating (120 V AC)\u003c\/td\u003e\n\u003ctd\u003e3 A @ 120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eMechanical\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Depth \/ Length\u003c\/td\u003e\n\u003ctd\u003e190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Height\u003c\/td\u003e\n\u003ctd\u003e118 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Width\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003e0.295 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCompliance\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Status\u003c\/td\u003e\n\u003ctd\u003eEU Directive 2011\/65\/EU compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Precaution:\u003c\/strong\u003e Disconnect all field voltage supplies and system power to the S+ SD I\/O carrier before installing or replacing modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Installation:\u003c\/strong\u003e Ensure the xBS02-EPD base unit is correctly installed and secured to the mounting rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Observe anti-static handling precautions during module unpackaging and insertion into the base connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the \u003cstrong\u003e8VZZ000167H1 DO05\u003c\/strong\u003e module guides with the xBS02-EPD slot and press firmly until fully seated and locked.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Verify that field relay loads do not exceed maximum contact current ratings across specific AC\/DC operating voltages (e.g., 3 A at 24 V DC \/ 120 V AC).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCommissioning Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Configuration Check:\u003c\/strong\u003e Verify that channel relay output configurations (NO\/NC) match the operational logic requirements of connected field devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation \u0026amp; Voltage Checks:\u003c\/strong\u003e Confirm external field supply levels are within nominal operating limits prior to enabling system output circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Testing:\u003c\/strong\u003e Force test individual output channels through the Symphony Plus engineering station to verify field coil energization and contact closure.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53764851171691,"sku":"8VZZ000167H1 DO05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8VZZ000167H1-DO05_1200x1200_d9d1614d-15a6-40d2-bb72-78e341ce0749.jpg?v=1787667997","url":"https:\/\/www.plcprotech.com\/products\/abb-8vzz000167h1-do05-16ch-digital-output-w-relay-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}