{"product_id":"abb-ac-800m-sm811k01-3bse018173r1-safety-cpu-module","title":"ABB AC 800M SM811K01 3BSE018173R1 Safety CPU Module","description":"\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe \u003cstrong\u003eSM811K01\u003c\/strong\u003e is a high-integrity processing component designed to execute functional safety applications within specialized distributed control frameworks. Operating as a dedicated \u003cstrong\u003esafety CPU module\u003c\/strong\u003e, this device provides diverse logical execution paths and extensive internal hardware diagnostics to protect complex industrial processes from critical failure states.\n\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThis unit is certified for use in safety loops up to \u003cstrong\u003eSIL3\u003c\/strong\u003e (Safety Integrity Level 3) according to IEC 61508, enforcing strict adherence to emergency shutdown logic and burner control parameters. To maintain standard system validation, the module must be configured in strict accordance with the official Safety Manual. The hardware package is delivered as a complete execution kit containing the SM811 processing module, a TP868 horizontal termination baseplate, and a TK852V10 high-speed synchronization link cable to handle real-time mirror processing vectors. \n\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n\u003cem\u003eRegulatory Note:\u003c\/em\u003e This specific hardware design is not RoHS 2 (2011\/65\/EU) compliant. It serves exclusively as an original spare part for legacy infrastructures placed on the market prior to July 22, 2017, and is intended solely for repair, functional updating, or capacity maintenance loops. For new greenfield installations, the RoHS-compliant SM812K01 sub-assembly must be specified instead.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eHigh-Integrity Functional Safety\u003c\/strong\u003e: Certified up to SIL3 thresholds to process safety interlocks, emergency shutdowns, and critical process mitigation loops.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eCEX Bus Communication Path\u003c\/strong\u003e: Establishes a secure connection to the communication extension bus interface directly after a BC810 CEX bus interconnection box.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eComplete Replacement Kit\u003c\/strong\u003e: Ships standard with the SM811 module, TP868 baseplate, and TK852V10 synchronization link cable for legacy rack maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eEmergency Shutdown Systems (ESD) deployed within legacy oil, gas, and petrochemical process control environments.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eBurner Management Systems (BMS) requiring diverse logical redundancy and validated interlock execution.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHigh Integrity Pressure Protection Systems (HIPPS) requiring rapid, deterministic safety loop processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe processing architecture limits direct physical and software coupling to the following approved system combinations:\n\u003c\/p\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eApproved Primary Controller\u003c\/strong\u003e: Collaborates natively alongside the PM865 master processor unit.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eBus Interface Unit\u003c\/strong\u003e: Connects to the primary system line via the BC810 CEX bus interconnection box.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSM811K01\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct ID Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3BSE018173R1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCore Module Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSM811\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Family\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAC 800M High Integrity\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDevice Classification\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSafety CPU module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Net Depth \/ Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e127.5 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Net Height\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e185 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Net Width\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e59 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Net Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.6 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSweden (SE)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCustoms Tariff Code Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNumber of Batteries Included\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePart Type Status Classification\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSpare Part (For systems marketed before July 22, 2017)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eComplete Rack De-energization\u003c\/strong\u003e: Completely isolate and lock out all auxiliary power lines supplying the rack baseplate before installing or adjusting the module framework. Verify zero electrical potential on the bus rails before inserting hardware.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eContinuous ESD Grounding Protocol\u003c\/strong\u003e: This high-integrity card houses low-power static-sensitive components. Maintenance engineers must remain bonded to a verified earth ground via an approved anti-static wrist strap throughout physical handling loops.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eBus and Termination Layout\u003c\/strong\u003e: Securely mount the TP868 baseplate to the standard rail, establishing clean physical alignment with adjacent extensions. Run the TK852V10 synchronization link cable evenly between the dedicated bus sockets, confirming the locking couplers engagement to stabilize data mirroring.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eCEX Interconnection Requirements\u003c\/strong\u003e: Ensure that the module bus interface maps correctly behind the BC810 CEX bus interconnection box to isolate safety communication from normal process line disturbances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem; margin-bottom: 1rem;\"\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eSIL3 certified for execution in functional safety architectures under IEC 61508 criteria.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eRegulatory Constraint Notice:\u003c\/strong\u003e Not RoHS 2 (2011\/65\/EU) compliant. Restricted strictly to repair and maintenance loops for legacy systems placed on the market prior to July 22, 2017.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668518039915,"sku":"SM811K01 3BSE018173R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-sm811k01-3bse018173r1-safety-cpu-module-n3ycumcqmlx_9564e198-27c9-4870-a6ba-8cbdc8f42a11.jpg?v=1765532722","url":"https:\/\/www.plcprotech.com\/products\/abb-ac-800m-sm811k01-3bse018173r1-safety-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}