{"product_id":"abb-acs550-01-023a-4-3aua0000002417-d-wall-mounted-variable-frequency-drive","title":"ABB ACS550-01-023A-4 3AUA0000002417-D Wall-Mounted Variable Frequency Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB ACS550-01-023A-4\u003c\/strong\u003e (Product ID: \u003cstrong\u003e3AUA0000002417-D\u003c\/strong\u003e) is a wall-mounted variable frequency drive designed for controlling standard three-phase AC induction motors in industrial and commercial processes. Operating across an input voltage range of 380 V to 480 V AC at 47.5 Hz to 63 Hz, this unit belongs to the ABB ACS550 drive family.\u003c\/p\u003e\n\u003cp\u003eEngineered around ABB's R2 frame size structure, the \u003cstrong\u003eACS550-01-023A-4\u003c\/strong\u003e supplies a continuous output current of 23 A for normal use applications up to 11 kW, as well as 15.4 A for heavy-duty applications rated up to 7.5 kW. Built in an IP21 \/ NEMA Type 1 enclosure, it delivers reliable motor speed and torque regulation across varying load profiles.\u003c\/p\u003e\n\u003cp\u003eThe drive satisfies strict power efficiency criteria, achieving an IE2 efficiency class rating with optimized power loss performance across variable operating points. It serves as a dependable motor controller for pumps, fans, conveyors, and general industrial machinery requiring stable speed control and energy optimization.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWall-mounted wall-drive construction built within an ABB R2 frame size.\u003c\/li\u003e\n\u003cli\u003eDual output capability supporting 23 A (11 kW) normal duty and 15.4 A (7.5 kW) heavy duty.\u003c\/li\u003e\n\u003cli\u003eAccepts 3-phase input supply voltage from 380 V to 480 V AC.\u003c\/li\u003e\n\u003cli\u003eEnclosure rated to IP21 and NEMA Type 1 protection standards.\u003c\/li\u003e\n\u003cli\u003eHigh-efficiency motor control compliant with IE2 efficiency level specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVariable speed control for industrial pumps, centrifuges, and fluid distribution networks.\u003c\/li\u003e\n\u003cli\u003eAir handling units, industrial supply\/exhaust fans, and HVAC ventilation systems.\u003c\/li\u003e\n\u003cli\u003eMaterial handling equipment, including belt conveyors, bucket elevators, and feeders.\u003c\/li\u003e\n\u003cli\u003eGeneral machinery automation requiring energy-efficient three-phase motor control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral \u0026amp; Electrical\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Type Designation\u003c\/td\u003e\n\u003ctd\u003eACS550-01-023A-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3AUA0000002417-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVariable Frequency Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Phases\u003c\/td\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage (Uin)\u003c\/td\u003e\n\u003ctd\u003e380...480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd\u003e47.5...63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current, Normal Use (In)\u003c\/td\u003e\n\u003ctd\u003e23 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power, Normal Use (Pn)\u003c\/td\u003e\n\u003ctd\u003e11 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current, Heavy-Duty Use (IHD)\u003c\/td\u003e\n\u003ctd\u003e15.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power, Heavy-Duty Use (PHD)\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency Level\u003c\/td\u003e\n\u003ctd\u003eIE2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePhysical \u0026amp; Environmental\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eWall-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type NEMA\u003c\/td\u003e\n\u003ctd\u003eType 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Dimensions (D x H x W)\u003c\/td\u003e\n\u003ctd\u003e565 mm x 365 mm x 225 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCompliance \u0026amp; Classifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code \/ Customs Tariff\u003c\/td\u003e\n\u003ctd\u003e85044099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003e4. Large Equipment (Any External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUNSPSC\u003c\/td\u003e\n\u003ctd\u003e39122001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Verification:\u003c\/strong\u003e Ensure the installation environment provides adequate ambient air circulation and remains within specified operational temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely mount the drive vertically on a flat, solid, non-flammable wall surface, maintaining recommended vertical clearance around the R2 frame for proper cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Wiring:\u003c\/strong\u003e Verify that incoming three-phase supply voltage is within the 380 V to 480 V range. Connect mains power cables and motor leads to their respective terminal blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Grounding:\u003c\/strong\u003e Connect a dedicated earth ground cable to the drive's protective earth terminal prior to energizing the unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl \u0026amp; Signal Wiring:\u003c\/strong\u003e Route control wiring separately from power and motor cables using shielded conductors to prevent noise interference.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eParameter Configuration:\u003c\/strong\u003e Configure drive application macros, motor nameplate data (voltage, current, frequency, RPM), and acceleration\/deceleration ramps using the control panel interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Tuning:\u003c\/strong\u003e Verify digital inputs, analog references, and relay outputs according to the system automation drawing prior to running the motor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement Recommendation:\u003c\/strong\u003e When replacing an existing ACS550 unit, record or back up all custom parameters from the old drive's control panel and verify that the replacement drive shares identical voltage and current ratings before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701958996331,"sku":"ACS550-01-023A-4","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ACS550-01-023A-4_1200x1200_321783a4-d8c1-4df7-b1bf-2696f8032b33.jpg?v=1787205948","url":"https:\/\/www.plcprotech.com\/products\/abb-acs550-01-023a-4-3aua0000002417-d-wall-mounted-variable-frequency-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}