{"product_id":"abb-acs580-01-033a-4-acs580-variable-speed-drive","title":"ABB ACS580-01-033A-4 ACS580 Variable Speed Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eOptimizing process control and energy efficiency in industrial pumping, ventilation, and mechanical conveying setups, the ABB ACS580-01-033A-4 wall-mounted variable speed drive delivers precise performance within the ACS580 series. This three-phase drive module is engineered to operate directly out of the box, offering plug-and-play motor control without extensive parameter setups. Equipped with an integrated control panel and built-in harmonic mitigation technology, the \u003cstrong\u003eABB ACS580-01-033A-4\u003c\/strong\u003e maintains high electrical efficiency and reliable system uptime in demanding process environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Harmonics Reduction:\u003c\/strong\u003e Built-in variable choke technology minimizes input current harmonics under both partial and full load conditions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAll-Compatible Architecture:\u003c\/strong\u003e Features a standardized parameter structure and user interface compatible with wider ABB drive portfolios.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafe Torque Off (STO):\u003c\/strong\u003e Built-in dual-channel STO safety function complies with SIL 3 \/ PL e requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEmbedded Modbus RTU:\u003c\/strong\u003e Integrated EIA-485 interface supports direct fieldbus communication without external gateway modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Energy Monitoring:\u003c\/strong\u003e Built-in calculators track energy consumption, savings in local currency, and CO2 reduction metrics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eCentrifugal pumps and booster stations in water\/wastewater treatment plants.\u003c\/li\u003e\n  \u003cli\u003eIndustrial supply and exhaust fans in HVAC and ventilation systems.\u003c\/li\u003e\n  \u003cli\u003eConveyor systems and material handling machinery requiring precise speed ramps.\u003c\/li\u003e\n  \u003cli\u003eCompressor control for refrigeration and manufacturing process air lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eACS580-01-033A-4\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eFrame Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eR3\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3-phase 380 to 480 VAC (+10% \/ -15%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNominal Output Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e33.0 A (at 400V, light-duty load)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eHeavy-Duty Output Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e25.0 A (at 400V)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Rating (Light-Duty)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e15.0 kW (20 HP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Rating (Heavy-Duty)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e11.0 kW (15 HP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eEnclosure Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP21 (UL Type 1)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMains Frequency\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e50 \/ 60 Hz (+\/- 5%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eControl Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eEmbedded Modbus RTU \/ Option slot for Fieldbus adapters\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-15 to +40 degC (no derating) \/ up to +50 degC (with derating)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eLogistics Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e12.25 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e85371091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e490 mm x 220 mm x 260 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eTerminal Block\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSignal \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eL1, L2, L3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3-phase AC main input supply\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eU2, V2, W2\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMotor output connections\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eUDC+, UDC-\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDC bus connections (for external braking units)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDI1 to DI6\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDigital inputs (programmable, PNP\/NPN config)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eAI1, AI2\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eAnalog inputs (voltage 0-10V or current 0-20mA selectable)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRO1, RO2, RO3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRelay outputs (250 VAC \/ 30 VDC, max 2 A)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOUT1, OUT2 (STO)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSafe Torque Off dual-channel safety loop\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo ensure long-term stability and reliable deployment in severe industrial setups, engineers should evaluate key operational limits and design parameters compiled from factory documentation and field deployments.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; font-weight: bold; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe ACS580-01-033A-4 is the standard IP21 (UL Type 1) wall-mounted drive. For environments heavily exposed to dust or moisture, the IP55-rated variant (ACS580-01-033A-4+B056) should be specified. This unit serves as a form-fit-function upgrade path for legacy ACS550-01-031A-4 drives, but panel layouts must account for minor mounting footprint updates and modernized control terminal mapping.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; font-weight: bold; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFor installations inside tight electrical enclosures, the R3 frame size requires at least 200 mm of vertical clearance above and 150 mm below the drive to prevent heat stagnation. Operating the drive above 40 degC triggers an output current derating factor of 1% per additional degC up to a maximum limit of 50 degC.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; font-weight: bold; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen utilizing the integrated EIA-485 Modbus RTU interface, remember to set the termination switch (J3) to the 'ON' position ONLY on the last physical drive in the network loop. Use shielded, symmetrical three-phase cabling for motor connections to significantly reduce electromagnetic emissions and minimize ground bearing currents.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL WARNING: HIGH VOLTAGE RISK\u003c\/p\u003e\n  \u003cp style=\"margin: 0.5rem 0 0 0; color: #2d3748;\"\u003eIsolate all power sources and verify complete de-energization on the AC input lines before commencing installation. Wait a minimum of 5 minutes after disconnecting the mains supply to allow the internal DC bus capacitors to discharge below hazardous voltage levels.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eMount the R3 frame module vertically onto a flat, non-flammable surface using appropriate M5 mounting screws. Maintain correct clearance profiles.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eRoute the input power, motor, and ground cables through the bottom gland plates. Connect the ground lead securely to the PE terminal.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eConnect the three-phase AC mains supply to terminals L1, L2, and L3, and the motor leads to U2, V2, and W2. Torque connections to specified nominal limits.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eTerminate control, feedback, and Safe Torque Off (STO) wiring to the designated low-voltage control terminals. Ensure separation of signal and high-power cables.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e5\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eReattach the front cover assembly before energizing. Configure the drive settings using the assistant control panel during initial start-up.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701955522923,"sku":"ACS580-01-033A-4","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/acs580-01-033a-4-w015cdhe4en_a5ef7189-7228-4193-9e99-9e48f1203048.jpg?v=1766478061","url":"https:\/\/www.plcprotech.com\/products\/abb-acs580-01-033a-4-acs580-variable-speed-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}