{"product_id":"abb-advant-controller-31-1sbp260100r1001-xi-16-e1-binary-extension","title":"ABB Advant Controller 31 1SBP260100R1001 XI 16 E1 Binary Extension","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 1SBP260100R1001\u003c\/strong\u003e is a high-performance \u003cstrong\u003eXI 16 E1 (XI16E1)\u003c\/strong\u003e binary extension module designed to expand the input capabilities of the \u003cstrong\u003eAC 31\u003c\/strong\u003e automation platform. Acting as a precise data collection node, this module features 16 isolated digital inputs rated at 24 V d.c., enabling reliable signal processing from standard field sensors. The electrical separation of 1500 V a.c. between the internal electronic logic and the external input channels protects the master controller against common-mode industrial surges and heavy noise interference. Operating seamlessly within the modular framework of the \u003cstrong\u003eAC 31\u003c\/strong\u003e platform, the \u003cstrong\u003e1SBP260100R1001\u003c\/strong\u003e transfers field signals over a secure local bus directly connected to central or remote base processing units. This architecture renders it optimal for large-scale distributed plant layouts requiring robust multi-channel digital signal collection over extended cable distances.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in 16 electrically isolated binary inputs rated for standard 24 V d.c. industrial field signals.\u003c\/li\u003e\n\u003cli\u003eRobust signal circuit architecture providing 1500 V a.c. galvanic isolation to safe-keep primary logic electronics.\u003c\/li\u003e\n\u003cli\u003eBus-powered architecture drawing 5 V logic power natively from the connected master central processing or remote base unit.\u003c\/li\u003e\n\u003cli\u003eIntegrated side-mounted ribbon cable configuration allowing simple chain attachment to adjacent input\/output expansions.\u003c\/li\u003e\n\u003cli\u003eClear status visualization panel with dedicated front-mounted LEDs indicating the physical runtime state of every input channel.\u003c\/li\u003e\n\u003cli\u003eCompact form factor with a universal mounting layout that effortlessly supports standard industrial DIN rails or direct rear-panel plate screw installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-point signal aggregation in automatic electrical contactor assembly lines and floorboard manufacturing lines.\u003c\/li\u003e\n\u003cli\u003eHigh-density digital sensor interfacing in heavy structural metal pipe welding systems and ceramic manufacturing machinery.\u003c\/li\u003e\n\u003cli\u003eRemote digital signaling networks for critical environmental handling, greenhouse climate regulation, and localized humidity controllers.\u003c\/li\u003e\n\u003cli\u003eDistributed logic tracking within decentralized utility plants including municipal water treatment stations and pumping installations.\u003c\/li\u003e\n\u003cli\u003eAuxiliary signaling and contact monitoring for high-capacity material handling systems, ski lift installations, and wind power machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eOrdering Information must be strictly evidence-based; if not explicitly present in source, omit entirely without explanation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\" style=\"width: 29.6029%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\" style=\"width: 70.0361%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\" style=\"width: 29.6029%;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"2\" style=\"width: 70.0361%;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\" style=\"width: 29.6029%;\"\u003eModel Reference\u003c\/td\u003e\n\u003ctd data-row=\"3\" style=\"width: 70.0361%;\"\u003eXI 16 E1 (XI16E1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\" style=\"width: 29.6029%;\"\u003eOrder Code \/ Product ID\u003c\/td\u003e\n\u003ctd data-row=\"4\" style=\"width: 70.0361%;\"\u003e1SBP260100R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\" style=\"width: 29.6029%;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd data-row=\"5\" style=\"width: 70.0361%;\"\u003eAdvant Controller 31 (AC 31)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\" style=\"width: 29.6029%;\"\u003eModule Type\u003c\/td\u003e\n\u003ctd data-row=\"6\" style=\"width: 70.0361%;\"\u003eBinary Extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\" style=\"width: 29.6029%;\"\u003eNumber of Binary Inputs\u003c\/td\u003e\n\u003ctd data-row=\"7\" style=\"width: 70.0361%;\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\" style=\"width: 29.6029%;\"\u003eInput Isolation Voltage\u003c\/td\u003e\n\u003ctd data-row=\"8\" style=\"width: 70.0361%;\"\u003e1500 V a.c. (between inputs and internal electronics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\" style=\"width: 29.6029%;\"\u003eInput Nominal Voltage\u003c\/td\u003e\n\u003ctd data-row=\"9\" style=\"width: 70.0361%;\"\u003e24 V d.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\" style=\"width: 29.6029%;\"\u003eModule Logic Power Supply\u003c\/td\u003e\n\u003ctd data-row=\"10\" style=\"width: 70.0361%;\"\u003e5 V d.c. supplied via the central unit or remote base unit connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\" style=\"width: 29.6029%;\"\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd data-row=\"11\" style=\"width: 70.0361%;\"\u003e220 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\" style=\"width: 29.6029%;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd data-row=\"12\" style=\"width: 70.0361%;\"\u003eFinland \/ United States \/ Romania\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eTerminal \/ Connection Slot\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eTop \u0026amp; Bottom Terminal Blocks\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eRemovable compression interfaces for connecting the external 24 V d.c. sensor power supply and the 16 binary input lines.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e0 V and 24 V d.c. Terminals\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eInternally linked bus voltage terminals for referencing the external sensor circuit power.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eLeft-Side Attached Cable\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eIntegrated data and logic link cable for primary coupling to the central unit or preceding extension module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eSupplementary Extension Slot\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eDedicated local bus socket for attaching subsequent downstream expansion hardware blocks.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Interruption Requirement:\u003c\/strong\u003e Ensure that all upstream power supplies are completely turned off before physically connecting or disconnecting the module to avoid internal hardware damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting Adaptation:\u003c\/strong\u003e Secure the device to a 35 mm DIN rail using the bottom support lock, or fasten it to an internal cabinet plate via 4 mm (M4) screws through the integrated base mounting holes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management Space:\u003c\/strong\u003e When placing the hardware inside a control cabinet, allow sufficient free volume around the unit boundaries to enable correct heat dissipation and maintain stable working parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Voltage Wiring:\u003c\/strong\u003e Connect the external 24 V d.c. sensor loop power directly to either the top or bottom power terminals; since these terminals are linked internally, only one set of 0 V and 24 V lines needs to be wired.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Cable Separation:\u003c\/strong\u003e Route low-voltage 24 V d.c. input lines away from high-power 230 V a.c. lines or heavy inductive device cables to suppress electromagnetic noise cross-talk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Tightening Torque:\u003c\/strong\u003e Fix all field wire connections into the removable screw terminal blocks using a standard terminal driver, maintaining a uniform tightening torque of exactly 0.5 Nm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the required voltage level for the binary input channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe binary inputs on this expansion module are designed to operate with a standard nominal voltage of 24 V d.c..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this extension board receive its internal electronic working power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is powered at 5 V d.c. directly through the communication bus link provided by the central unit or extensible remote base to which it is attached.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I plug this module into a running system while the primary controller is energized?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, you must completely isolate and turn off the power supply before attaching or detaching any extension hardware blocks to avoid circuit faults.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the dielectric safety rating between the inputs and internal electronics?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe input channels feature complete electrical isolation rated at 1500 V a.c. to prevent high-voltage spikes from penetrating the core processing logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of cabling connector can be used for fast wiring on this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is compatible with 07 ST 55 cage-clamp type connectors, which allow rapid wire insertion by pressing with a screwdriver.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can a technician quickly check if a specific binary input channel is active?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe front panel includes a dedicated status visualization area where local LEDs light up to display the active state of each individual input channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this hardware module support mounting on an internal cabinet plate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it can be mounted using direct plate screw fixation with 4 mm M4 screws through the integrated holes located at the base of the housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the total baseline weight of an individual binary extension unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module has a clean engineering net equipment weight of exactly 220 g.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many total input channels are provided by a single expansion unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach unit provides exactly 16 isolated binary input channels for industrial field signal monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre the top and bottom 24 V d.c. power terminals separated or connected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 0 V and 24 V d.c. terminals on both terminal blocks are connected internally, requiring only a single power feed connection from the external sensor supply.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668612411755,"sku":"XI16E1 1SBP260100R1001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-xi16e1-1sbp260100r1001-extensible-remote-unit-nsunzfdaag0_7afb4f55-c3a7-42e9-84ed-c04d3276ac37.jpg?v=1765535535","url":"https:\/\/www.plcprotech.com\/products\/abb-advant-controller-31-1sbp260100r1001-xi-16-e1-binary-extension","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}