{"product_id":"abb-ai845-3bse023675r1-s800-i-o-analog-input-module","title":"ABB AI845 3BSE023675R1 S800 I\/O Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAI845\u003c\/strong\u003e with product ID \u003cstrong\u003e3BSE023675R1\u003c\/strong\u003e is an 8-channel analog input module designed for the S800 I\/O distributed system architecture. This hardware unit interfaces standard 0 to 20 mA or 4 to 20 mA current signals from field transmitters directly to the central processing controller. It incorporates dedicated HART routing capabilities per channel, enabling bi-directional communication with smart instruments over existing analog loops without altering regular process variable transmission. It provides dual-channel hardware redundancy options when paired with appropriate terminal units, maintaining active signal paths and system availability during single module exceptions.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 8 single-ended current tracking input channels supporting 0 to 20 mA or 4 to 20 mA signals.\u003c\/li\u003e\n\u003cli\u003eIntegrates channel-by-channel HART pass-through communication for asset management systems.\u003c\/li\u003e\n\u003cli\u003eSupports hot-swapping and fully redundant configurations for uninterrupted process data acquisition.\u003c\/li\u003e\n\u003cli\u003eFeatures integrated diagnostic routines to supervise open-circuit monitoring and out-of-range signal states.\u003c\/li\u003e\n\u003cli\u003eUtilizes compact electrical termination setups using standard S800 Module Termination Units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-availability process loop telemetry inside petrochemical refining and power generation units.\u003c\/li\u003e\n\u003cli\u003eDual-fault tolerant interface links interfacing safety parameters with distributed control systems.\u003c\/li\u003e\n\u003cli\u003eAsset management integration utilizing remote HART diagnostic mapping protocols.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAI845\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE023675R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 single-ended channels (redundancy supported)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA \/ 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit A\/D conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHART Protocol Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, pass-through per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC internal consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSweden (SE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel 1 Signal Input (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel 2 Signal Input (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel 3 Signal Input (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel 4 Signal Input (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel 5 Signal Input (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel 6 Signal Input (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel 7 Signal Input (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel 8 Signal Input (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9 to 16\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel Signal Return \/ Common Ground (0V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Insertion\u003c\/strong\u003e: Verify that the Module Termination Unit (such as TU844 or TU845) is secured onto the DIN rail before engaging the module body. Disconnect primary electrical feeds, align the plastic guide tabs, and apply uniform vertical force until the side retention latches click home.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Protocol\u003c\/strong\u003e: Terminate the outer metal mesh of twisted-pair instrument wires using the ground bars situated on the enclosure entry frame. Maintain single-point earth terminations at the control cabinet wall to eliminate low-frequency ground-loop feedback.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Configuration\u003c\/strong\u003e: To execute redundant module deployments, both units must reside in an identical, paired-slot termination cluster. Map the master\/backup hierarchy inside the control programming software to handle hot-standby functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Separation Routing\u003c\/strong\u003e: Route low-current operational signals in separate wiring ducts isolated from variable speed drives, bulk contactor control blocks, and heavy three-phase power buses by a minimal clear air threshold of 30 cm.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701955916139,"sku":"3BSE023675R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse023675r1-gu1p3aqzaub_06616861-c453-4b2e-9abe-458dadb57d0f.jpg?v=1766478073","url":"https:\/\/www.plcprotech.com\/products\/abb-ai845-3bse023675r1-s800-i-o-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}