{"product_id":"abb-bailey-imdso14-infi-90-digital-output-module","title":"ABB Bailey IMDSO14 INFI 90 Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB Bailey IMDSO14\u003c\/strong\u003e Digital Output Module functions as an interface between the INFI 90 OPEN Strategic Process Management System and process field devices. It receives commands from control modules—such as the multi-function processor (MFP), multi-function controller (MFC), or logic master module (LMM)—over the I\/O expander bus to switch field equipment ON or OFF. The \u003cstrong\u003eIMDSO14\u003c\/strong\u003e provides 16 digital outputs through solid-state circuitry, where 12 outputs are individually isolated and two pairs share positive output terminals. It handles 24 VDC or 48 VDC load voltages and serves as a direct replacement for the IMDSO04 module.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 digital output channels divided into Group A and Group B\u003c\/li\u003e\n\u003cli\u003eSolid-state open-collector switching circuitry\u003c\/li\u003e\n\u003cli\u003eOptocouplers providing electrical isolation between module logic and process circuits\u003c\/li\u003e\n\u003cli\u003eOn-board bus fault timer to default outputs during communication loss\u003c\/li\u003e\n\u003cli\u003eFront panel status LEDs for module health and individual output channel states\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSwitching process field devices and relays\u003c\/li\u003e\n\u003cli\u003eDigital ON\/OFF process control\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and process management systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB \/ Elsag Bailey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements (Voltage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VDC (+\/-5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements (Current)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e275 mA (typical), 370 mA (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation (Logic Only)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.375 W (typical), 1.850 W (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 digital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Current (Maximum)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 mA (24 VDC), 125 mA (48 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff Leakage Current (Maximum)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 uA at 70 degC (158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn Voltage Drop (Maximum)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 V at 70 degC (158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption per Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 mA typical \/ 250 mA max (24 VDC), 75 mA typical \/ 125 mA max (48 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation (Channel-to-Channel \u0026amp; Channel-to-Logic)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Mohm insulation resistance, 1 kV rms \/ 1 min or 1.5 kVDC \/ 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOccupies one slot in a standard INFI 90 OPEN module mounting unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Cabinet Internal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 70 degC (32 to 158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% up to 55 degC (131 degF) noncondensing, 5% to 45% at 70 degC (158 degF) noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAtmospheric Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSea level to 3 km (1.86 miles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir Quality\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA S71.04, Class LA, LB, LC-level 1 (Noncorrosive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP1 Pins 1, 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 VDC Logic Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP1 Pins 5, 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP1 Pins 9, 10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Fail Interrupt (PFI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP1 Pins 3, 4, 7, 8, 11, 12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNC (Not Connected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP2 Pins 1 to 8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/O Expander Bus Data Lines (Data 0 to Data 7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP2 Pin 9\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/O Expander Bus Clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP2 Pin 10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/O Expander Bus Sync\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP2 Pins 11, 12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNC (Not Connected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 Group A Pins A\/1 to H\/J\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Output Signals 1 to 8 (Group A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 Group B Pins K\/9 to S\/8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Output Signals 9 to 16 (Group B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse grounded wrist straps and anti-static procedures when handling the module to protect static-sensitive devices.\u003c\/li\u003e\n\u003cli\u003eSet the 8-position address dipswitch (S1) to match the address defined in Function Code 83 (Specification S1) before inserting the module into the rack.\u003c\/li\u003e\n\u003cli\u003eEnsure a dipshunt is properly installed in the I\/O expander bus socket on the backplane between the control module and the output module.\u003c\/li\u003e\n\u003cli\u003eDisconnect system power before installing dipshunts on the MMU backplane to avoid electrical shock hazards.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the guide rails in the module mounting unit and slide it in until the front panel is flush; latch the two faceplate captive retaining screws.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE Mark Declaration (EMC96 Directive 89\/336\/EEC: EN 50081-2, EN 50082-2)\u003c\/li\u003e\n\u003cli\u003eCSA Certified (Ordinary nonhazardous locations per CSA C22.2 No. 1010.1-92)\u003c\/li\u003e\n\u003cli\u003eFM Approved (Nonincendive for Class I, Division 2, Groups A, B, C, D; Class II, Division 2, Groups F, G)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668627812715,"sku":"IMDSO14","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-imdso14-digital-output-module-lk413sknqd0_c53130fd-5882-43c5-ae59-3118be31da1c.jpg?v=1765536051","url":"https:\/\/www.plcprotech.com\/products\/abb-bailey-imdso14-infi-90-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}