{"product_id":"abb-bailey-ntai06-infi-90-analog-input-termination-unit","title":"ABB Bailey NTAI06 Infi 90 Analog Input Termination Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eNTAI06\u003c\/strong\u003e is a 16-channel analog input termination unit designed to terminate field wiring in process control applications. It consists of a single printed circuit board that mounts directly in an \u003cstrong\u003eNFTP01 Field Termination Panel\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe unit routes analog field signals to compatible slave modules, including the \u003ca href=\"https:\/\/www.plcprotech.com\/products\/abb-imasi03-bailey-infi-90-analog-input-slave-module\"\u003e\u003cstrong\u003eIMASI03\u003c\/strong\u003e\u003c\/a\u003e, as well as the \u003cstrong\u003eIMMFP01\u003c\/strong\u003e, \u003cstrong\u003eIMMFP02\u003c\/strong\u003e, and \u003cstrong\u003eIMMFP03 Multi-Function Processors\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eEach channel can be configured independently for several analog input types, including differential voltage, single-ended voltage, system-powered or externally powered 4–20 mA current loops, thermocouples, millivolt signals, and 3-wire RTDs.\u003c\/p\u003e\n\u003cp\u003eIntegrated cold junction reference RTDs provide thermocouple compensation. On-board transient and surge protection helps maintain signal integrity and protect connected system components.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to 16 independent analog input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccepts 12 to 22 AWG field wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUses on-board compression fitting terminal blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides per-channel signal configuration through on-board jumpers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes individual fuses for system-powered 4–20 mA input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes cold junction reference RTDs for thermocouple compensation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides input channel transient and surge protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnects to slave modules through NKAS01 or NKAS11 shielded cable assemblies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports cable lengths up to 60 meters (200 feet)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounts directly in an NFTP01 Field Termination Panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eINFI 90 process management system field signal termination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed Control System analog input routing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-channel temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess variable measurement and monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermocouple, RTD, voltage, and current signal termination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent or Spare Part\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNTAI06 Revision A Hardware\u003c\/td\u003e\n\u003ctd\u003eAssembly number; includes fuse F17\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6639364A1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNTAI06 Revision B Hardware\u003c\/td\u003e\n\u003ctd\u003eAssembly number; includes additional filter capacitors\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6639364B1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse F1–F16\u003c\/td\u003e\n\u003ctd\u003e31.25 mA, 125 V; 6.35 mm diameter × 8.89 mm height\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1945820A10310\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse F17\u003c\/td\u003e\n\u003ctd\u003e2.0 A slow-blow fuse, 250 V; 5 × 20 mm\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1948182A32001\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNKAS01 Cable\u003c\/td\u003e\n\u003ctd\u003ePVC insulation, 80°C, 300 V, UL CL2\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNKAS01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNKAS11 Cable\u003c\/td\u003e\n\u003ctd\u003eNon-PVC insulation, 90°C, 300 V, UL PLTC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNKAS11\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNFTP01\u003c\/td\u003e\n\u003ctd\u003eField Termination Panel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNFTP01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEFAS01\u003c\/td\u003e\n\u003ctd\u003eINFI 90 Fastener Kit\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEFAS01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB \/ Bailey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNTAI06\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABB Type Designation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNTAI06\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModule Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003eSingle-ended voltage, differential voltage, system-powered 4–20 mA, externally powered 4–20 mA, 3-wire RTD, thermocouple, millivolt, and high-level voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Types\u003c\/td\u003e\n\u003ctd\u003eE, J, K, L, N, R, S, T, U, Chinese E, and Chinese S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMillivolt Input Range\u003c\/td\u003e\n\u003ctd\u003e−100 mV to +100 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Level Input Range\u003c\/td\u003e\n\u003ctd\u003e−10 V to +10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e+24 VDC for system-powered 4–20 mA inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Size\u003c\/td\u003e\n\u003ctd\u003e12 to 22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eMounts in an NFTP01 Field Termination Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e96.52 × 236.22 × 218.44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.635 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 90% ±5% up to 55°C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity at 70°C\u003c\/td\u003e\n\u003ctd\u003e5% to 40% ±5%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric Pressure\u003c\/td\u003e\n\u003ctd\u003eSea level to 3 km (1.86 miles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Quality\u003c\/td\u003e\n\u003ctd\u003eNoncorrosive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNo additional cooling required when installed in Bailey Controls cabinets within the specified limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff \/ HS Code\u003c\/td\u003e\n\u003ctd\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eP1 Connector\u003c\/td\u003e\n\u003ctd\u003eMale 36-pin connector for the NKAS cable J2 branch; carries input channels 1 through 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP2 Connector\u003c\/td\u003e\n\u003ctd\u003eMale 24-pin connector for the NKAS cable J3 branch; carries input channels 11 through 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB1 Terminal Block\u003c\/td\u003e\n\u003ctd\u003eCompression terminals for input channels 1 through 8; includes positive, negative, and common connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTB2 Terminal Block\u003c\/td\u003e\n\u003ctd\u003eCompression terminals for input channels 9 through 16; includes positive, negative, and common connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE1 Fast-On Terminal\u003c\/td\u003e\n\u003ctd\u003e+24 VDC system power connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2 Fast-On Terminal\u003c\/td\u003e\n\u003ctd\u003eI\/O COM connection to the DC bus bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Screw\u003c\/td\u003e\n\u003ctd\u003eChassis ground connection to the NFTP01 panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eWear a static-grounding wrist strap when handling the termination unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse a static-dissipating work surface when working with exposed electronic circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisconnect cabinet power and I\/O power before wiring or servicing the unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemove assigned slave modules or termination modules before installing connecting cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsert the termination unit tabs into the outer edge slots of the NFTP01 panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the unit using two No. 10 screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the chassis ground using a No. 10 self-tapping screw and an external star lock washer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigure channel jumpers \u003cstrong\u003eJ1 through J64\u003c\/strong\u003e for the required voltage, current, RTD, or thermocouple input type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eComplete all jumper configuration before applying power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the RTD cover over the terminal blocks when thermocouple inputs are used.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCorrect RTD cover installation is required for accurate cold junction compensation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect power wiring using 14 AWG wire.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect \u003cstrong\u003eE1\u003c\/strong\u003e to the +24 VDC supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect \u003cstrong\u003eE2\u003c\/strong\u003e to the DC bus bar or I\/O COM connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eNTAI06\u003c\/strong\u003e is CSA certified for use as process control equipment in ordinary, nonhazardous locations.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53595557888363,"sku":"NTAI06","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/NTAI06_1.jpg?v=1784783515","url":"https:\/\/www.plcprotech.com\/products\/abb-bailey-ntai06-infi-90-analog-input-termination-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}