{"product_id":"abb-ci852k01-3bse018102r1-foundation-fieldbus-h1-communication-interface-module","title":"ABB CI852K01 3BSE018102R1 Foundation Fieldbus H1 Communication Interface Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 3BSE018102R1 CI852K01\u003c\/strong\u003e is a Foundation Fieldbus H1 interface kit designed to integrate field-level Foundation Fieldbus instruments with ABB System 800xA AC 800M controller hardware platforms. The module acts as a dedicated communication link between the AC 800M controller CEX-bus and Foundation Fieldbus H1 networks, executing deterministic process control data exchange at standard 31.25 kbit\/s fieldbus transmission rates.\u003c\/p\u003e\n\u003cp\u003eThe kit includes the \u003cstrong\u003eCI852\u003c\/strong\u003e communication interface unit and the matching \u003cstrong\u003eTP852\u003c\/strong\u003e module baseplate (60 mm width). Mounting directly to the AC 800M controller assembly via the baseplate interface, the module provides a single Foundation Fieldbus H1 channel to handle real-time input\/output signal transfer, device diagnostics, and field-level instrument configuration management.\u003c\/p\u003e\n\u003cp\u003eDesigned for industrial process automation, the \u003cstrong\u003e3BSE018102R1 CI852K01\u003c\/strong\u003e interface kit facilitates seamless fieldbus segment deployment across process control applications. It handles direct communication with smart transmitters, control valves, and field analyzers, serving as a reliable communication gateway across AC 800M hardware revisions 4.1, 5.0, and 5.1.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFoundation Fieldbus H1 Interface:\u003c\/strong\u003e Executes single-channel Foundation Fieldbus H1 protocol communication operating at standard 31.25 kbit\/s transmission speeds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete System Kit Assembly:\u003c\/strong\u003e Includes the CI852 communication interface module alongside the dedicated 60 mm wide TP852 baseplate for simplified installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC 800M Controller Integration:\u003c\/strong\u003e Direct bus architecture compatibility with ABB System 800xA AC 800M controller hardware ranges across versions 4.1, 5.0, and 5.1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-Channel Field Connection:\u003c\/strong\u003e Manages a single fieldbus H1 segment to handle real-time field device cyclic data exchange and non-cyclic diagnostic data routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Industrial Form Factor:\u003c\/strong\u003e Compact module footprint with net dimensions of 16 cm width by 9 cm height by 25 cm depth for DIN-rail or baseplate mounting within system cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Fieldbus Integration:\u003c\/strong\u003e Linking Foundation Fieldbus H1 field devices, including pressure transmitters, flowmeters, and smart valve positioners, to ABB System 800xA DCS architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Device Diagnostics \u0026amp; Asset Management:\u003c\/strong\u003e Routing instrument condition monitoring, calibration, and configuration data between field transmitters and central engineering stations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed Control Systems:\u003c\/strong\u003e Handling field-level regulatory control loops and distributed device network execution within continuous processing facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Model \/ Order Code\u003c\/td\u003e\n\u003ctd\u003e3BSE018102R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABB Type Designation\u003c\/td\u003e\n\u003ctd\u003eCI852K01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Designation\u003c\/td\u003e\n\u003ctd\u003eCI852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate Designation\u003c\/td\u003e\n\u003ctd\u003eTP852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Module Interface Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Type\u003c\/td\u003e\n\u003ctd\u003eFoundation Fieldbus H1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Speed\u003c\/td\u003e\n\u003ctd\u003e31.25 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible System Platform\u003c\/td\u003e\n\u003ctd\u003eABB System 800xA \/ AC 800M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Hardware Series\u003c\/td\u003e\n\u003ctd\u003eAC 800M Hardware 4.1, 5.0, 5.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Width\u003c\/td\u003e\n\u003ctd\u003e16 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Height\u003c\/td\u003e\n\u003ctd\u003e9 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Depth \/ Length\u003c\/td\u003e\n\u003ctd\u003e25 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003e650 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Gross Volume\u003c\/td\u003e\n\u003ctd\u003e3.6 dm3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Gross Weight\u003c\/td\u003e\n\u003ctd\u003e650 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Country of Origin\u003c\/td\u003e\n\u003ctd\u003eSweden \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent \/ Interface\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCI852 Communication Module\u003c\/td\u003e\n\u003ctd\u003eMain processing module for Foundation Fieldbus H1 protocol conversion and routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTP852 Baseplate (60 mm)\u003c\/td\u003e\n\u003ctd\u003eMounting baseplate providing backplane bus interconnection and field wiring terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Verification:\u003c\/strong\u003e Inspect the kit components (CI852 module and TP852 baseplate) for physical damage and verify compatibility with the target AC 800M controller system version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Ensure the controller rack and backplane power supply are turned off before attaching or removing module components to prevent bus communication faults or damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Mounting:\u003c\/strong\u003e Securely latch the 60 mm TP852 baseplate onto the DIN rail adjacent to the AC 800M controller or preceding CEX-bus module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Integration:\u003c\/strong\u003e Connect the Foundation Fieldbus H1 segment wiring to the assigned terminals on the TP852 baseplate, ensuring proper polarity and segment termination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the CI852 module with the guide slots on the TP852 baseplate and press firmly until the module locks into the connector base.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning Checks:\u003c\/strong\u003e Restore system power, load the configuration settings via ABB Control Builder \/ System 800xA software, and verify active fieldbus communication status indicators.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Hardware Setup:\u003c\/strong\u003e Define the CI852 module within the hardware tree of the System 800xA \/ Control Builder engineering environment under the respective AC 800M controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Parameter Alignment:\u003c\/strong\u003e Set channel parameters to match the 31.25 kbit\/s Foundation Fieldbus H1 segment configuration and scheduled function blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Identification:\u003c\/strong\u003e Import or assign the appropriate Device Descriptions (DD \/ EDD) or Field Device Tools (FDT\/DTM) for connected H1 field instruments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Backup:\u003c\/strong\u003e Save and archive the controller hardware layout and fieldbus network configuration file prior to initiating full online operations.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668624699755,"sku":"CI852K01 3BSE018102R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CI852K01-3BSE018102R1_1200x1200_245e2e8d-1bab-4012-9abc-4badace50fcf.jpg?v=1787713593","url":"https:\/\/www.plcprotech.com\/products\/abb-ci852k01-3bse018102r1-foundation-fieldbus-h1-communication-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}