{"product_id":"abb-di830-3bse013210r1-s800-i-o-digital-input-soe-module","title":"ABB DI830 3BSE013210R1 S800 I\/O Digital Input SOE Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe ABB DI830 3BSE013210R1 is a high-performance digital input module featuring Sequence of Events (SOE) recording capabilities, designed for use within the ABB S800 I\/O system architecture. This module is engineered to interface field digital signals to a control system while capturing state changes with high time-tagging resolution, making it critical for root-cause analysis and sequence monitoring in demanding industrial automation environments. It integrates directly with ABB distributed control systems, providing reliable signal acquisition and rapid event logging for power generation, oil and gas, and heavy process industries.\u003c\/p\u003e\n\u003cp\u003eOperating as part of the modular S800 I\/O platform, the DI830 supports hot-swapping for maintenance without process interruption when configured with redundant MTU (Module Termination Unit) base plates. Its robust electronic design ensures high availability, noise immunity, and precise time synchronization across distributed nodes in the control network.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSequence of Events (SOE) recording with high-resolution time stamping for precise fault and event analysis\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for the ABB S800 I\/O distributed modular platform\u003c\/li\u003e\n  \u003cli\u003eSupports redundant configuration capability for high-availability system requirements\u003c\/li\u003e\n  \u003cli\u003eHot-swappable module replacement simplifies field maintenance without system shutdowns\u003c\/li\u003e\n  \u003cli\u003eGalvanic isolation between field inputs and system logic for enhanced signal integrity\u003c\/li\u003e\n  \u003cli\u003eAdvanced internal diagnostics and status LED indicators for rapid troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDistributed Control Systems (DCS) for power generation plants\u003c\/li\u003e\n  \u003cli\u003eEmergency shutdown and safety-adjacent sequence monitoring in oil and gas refineries\u003c\/li\u003e\n  \u003cli\u003eHigh-speed event tracking in chemical and petrochemical processing facilities\u003c\/li\u003e\n  \u003cli\u003eElectrical substation automation requiring exact sequence-of-events chronological logging\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eS800 I\/O\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003eDI830\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOrdering Code\u003c\/td\u003e\n      \u003ctd\u003e3BSE013210R1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eDigital Input SOE Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd\u003e16 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e24 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIsolation\u003c\/td\u003e\n      \u003ctd\u003eChannel-to-module and channel-to-ground isolation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTime Resolution (SOE)\u003c\/td\u003e\n      \u003ctd\u003e1 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignalling\u003c\/td\u003e\n      \u003ctd\u003eLED indicators for module status, faults, and channel states\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003eDIN rail via S800 Module Termination Unit (MTU)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eSweden\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e0.20 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e45 x 105 x 120 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 to +70 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Bus (ModuleConnect)\u003c\/td\u003e\n      \u003ctd\u003eCommunication and power distribution backplane interface to MTU \/ Cluster\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eField Terminals (via MTU)\u003c\/td\u003e\n      \u003ctd\u003e16 digital input signal connections and reference commons\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the part number DI830 3BSE013210R1 matches your system engineering documentation and that the corresponding Module Termination Unit (MTU) is correctly installed on the DIN rail.\u003c\/li\u003e\n  \u003cli\u003eEnsure the system power and field power supplies are de-energized before handling or inserting hardware modules.\u003c\/li\u003e\n  \u003cli\u003eInspect the module connector pins and MTU socket for dust, damage, or foreign objects.\u003c\/li\u003e\n  \u003cli\u003eAlign the DI830 module with the guide slots on the MTU and press firmly until the mechanical locking mechanism engages.\u003c\/li\u003e\n  \u003cli\u003eRestore power and verify module health through the engineering station diagnostics and front-panel LED indicators.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668624109931,"sku":"DI830 3BSE013210R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-di830-3bse013210r1-digital-input-soe-module-k5stayboiba_3a3a53e0-be6e-4d0b-b255-c8660b3d44da.jpg?v=1765535913","url":"https:\/\/www.plcprotech.com\/products\/abb-di830-3bse013210r1-s800-i-o-digital-input-soe-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}