{"product_id":"abb-do810-3bse008510r1-s800-i-o-digital-output-module","title":"ABB DO810 3BSE008510R1 S800 I\/O Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe ABB DO810 3BSE008510R1 is a 16-channel digital output module designed specifically for deployment within the ABB S800 I\/O distributed control system architecture. This module serves as a critical interface between controller logic and field actuators, providing precise switching control for industrial automation processes. Operating within a 24 V DC nominal supply range, the DO810 facilitates reliable command execution for valves, contactors, and indicator lamps in process and discrete manufacturing environments.\u003c\/p\u003e\n\u003cp\u003eEngineering features include two isolated channel groups of eight outputs each, providing independent supervision and fault isolation. The module integrates comprehensive diagnostics, including optical channel isolation, short-circuit protection, and process voltage supervision. Communication with the parent controller and system redundancy structures is handled efficiently via the ModuleBus interface, ensuring continuous operational visibility and rapid fault detection during abnormal plant conditions.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e16 digital output channels configured in two isolated groups of 8\u003c\/li\u003e\n  \u003cli\u003eNominal output voltage range of 24 V DC (10 to 30 V DC limits)\u003c\/li\u003e\n  \u003cli\u003eMaximum continuous output current of 0.5 A per channel\u003c\/li\u003e\n  \u003cli\u003eShort-circuit and thermal overload protection per channel\u003c\/li\u003e\n  \u003cli\u003eOptical isolation between field signals and internal system logic\u003c\/li\u003e\n  \u003cli\u003eBuilt-in inductive load suppression and EMC filtering\u003c\/li\u003e\n  \u003cli\u003eModuleBus communication interface for controller connectivity and diagnostics\u003c\/li\u003e\n  \u003cli\u003eFront-panel LED indicators for channel status, error states, and power supervision\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDistributed Control Systems (DCS)\u003c\/li\u003e\n  \u003cli\u003eProcess manufacturing and chemical plants\u003c\/li\u003e\n  \u003cli\u003ePower generation and distribution facilities\u003c\/li\u003e\n  \u003cli\u003eOil and gas upstream and downstream automation\u003c\/li\u003e\n  \u003cli\u003eDiscrete machinery and factory automation control panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eS800 I\/O\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model \/ Ordering Number\u003c\/td\u003e\n      \u003ctd\u003eDO810 3BSE008510R1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eDigital Output Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eSweden\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e0.21 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 135 mm x 103 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e10 to 30 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd\u003e16 channels (2 groups of 8)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Current per Channel\u003c\/td\u003e\n      \u003ctd\u003e0.5 A max (continuous)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIsolation\u003c\/td\u003e\n      \u003ctd\u003eGroupwise galvanic isolation from internal logic\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Dissipation\u003c\/td\u003e\n      \u003ctd\u003e2.5 W max\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEnvironmental and Mechanical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 to 70 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 to 85 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e5 to 95 percent (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003eDIN rail or S800 mounting base\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the part number DO810 3BSE008510R1 matches your system engineering documentation.\u003c\/li\u003e\n  \u003cli\u003eEnsure all power to the target S800 I\/O base unit and field terminal blocks is completely de-energized before handling.\u003c\/li\u003e\n  \u003cli\u003eInspect the module housing, pins, and locking mechanisms for any transit damage.\u003c\/li\u003e\n  \u003cli\u003eAlign the module with the correct S800 base unit slot and gently press straight in until the locking mechanism engages securely.\u003c\/li\u003e\n  \u003cli\u003eConnect field wiring to the corresponding terminal blocks according to the system installation schematic.\u003c\/li\u003e\n  \u003cli\u003eRestore system power and verify that the module initializes correctly via the controller diagnostic environment.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668513616235,"sku":"DO810 3BSE008510R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-do810-3bse008510r1-digital-output-module-5hz4royigrp_0e3ec44a-eade-4d29-af7c-bc285e1f871e.jpg?v=1765532593","url":"https:\/\/www.plcprotech.com\/products\/abb-do810-3bse008510r1-s800-i-o-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}