{"product_id":"abb-drives-sdcs-pow-1-dcs-500-power-supply-board","title":"ABB Drives SDCS-POW-1 DCS 500 Power Supply Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSDCS-POW-1\u003c\/strong\u003e is a switched-mode power supply board designed for use in DCS 500 converter modules. Mounted directly on the electronic support framework, this unit functions in a flyback configuration to generate all required internal DC operating voltages for the SDCS-CON-2 main control board and associated electronic peripheral boards. The board features universal system adaptability, operating independently of the specific current or voltage ratings of the drive module. It accommodates standard dual-voltage AC mains inputs, selectable via an onboard slide switch, and includes dedicated jumper configurations to manage encoder power distribution based on the specific control board and I\/O board pairing in use.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSwitched-mode flyback power supply configuration for efficient internal DC distribution.\u003c\/li\u003e\n\u003cli\u003eIndependent operation across the entire current and voltage range of DCS 500 modules.\u003c\/li\u003e\n\u003cli\u003eOnboard selector switch (SW1) for manual selection between 115 V AC and 230 V AC input lines.\u003c\/li\u003e\n\u003cli\u003eConfigurable encoder supply voltage output via hardware jumpers X3, X4, and X5.\u003c\/li\u003e\n\u003cli\u003eDedicated integration terminals for connecting external backup capacitance to extend mains buffering runtime.\u003c\/li\u003e\n\u003cli\u003ePotential-isolated relay output (X96-DO8) featuring an integrated metal-oxide varistor (MOV) for transient protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDCS 500 industrial DC drive converter modules.\u003c\/li\u003e\n\u003cli\u003eInternal DC voltage distribution and control board powering.\u003c\/li\u003e\n\u003cli\u003ePulse encoder voltage supply management in motor speed measurement loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSDCS-POW-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFinland (FI) \/ Saudi Arabia (SA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85049090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.44 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGross Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 m3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 mm x 135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpare_Parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Supply Input Voltage Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 V AC \/ 230 V AC (Switch SW1 selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15% \/ +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 Hz to 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 W or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current (115 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A for 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current (230 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A for 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMains Buffering Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 ms minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput X96-DO8 Contact Rating (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V~ or less \/ 3 A~ or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput X96-DO8 Contact Rating (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V- or less \/ 3 A- or less (or 115\/230 V- or less \/ 0.3 A- or less)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMOV Element Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e275 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUNSPSC Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e391220043\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eJumper and Switch Configuration\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction \/ Setting\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSW1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Supply Selection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePosition Left: 230 V AC (Default)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003ePosition Right: 115 V AC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX3, X4, X5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEncoder Supply Selection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e5 V Output (Default):\u003c\/strong\u003e Jumpers set to Position A on X5, X4, X3 (Sense function: Yes)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e12 V Output:\u003c\/strong\u003e Jumpers set to Pos B on X5, Pos B on X4, Pos A on X3 (Sense function: Yes)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e15 V Output:\u003c\/strong\u003e Jumpers set to Pos A on X5, Pos A on X4, Pos B on X3 (Sense function: No)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e24 V Output:\u003c\/strong\u003e Jumpers set to Pos B on X5, Pos B on X4, Pos B on X3 (Sense function: No)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTerminal Assignments\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX99 (N, L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Supply Input\u003c\/td\u003e\n\u003ctd\u003eMain AC power supply input terminals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX96 (1, 2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Output (DO8)\u003c\/td\u003e\n\u003ctd\u003ePotential-isolated normally open (NO) contact with MOV protection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX95\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackup Supply Terminals\u003c\/td\u003e\n\u003ctd\u003eConnection points for adding external capacitance (e.g., KJ 2001) to increase mains buffering time.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX37\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterface Connector\u003c\/td\u003e\n\u003ctd\u003e26-pin ribbon cable interface connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX5 B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTest Terminal\u003c\/td\u003e\n\u003ctd\u003eHardware test point for checking +5 V level (valid when 5 V output is selected).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX3 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTest Terminal\u003c\/td\u003e\n\u003ctd\u003eHardware test point for checking +15 V level.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eX3 B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTest Terminal\u003c\/td\u003e\n\u003ctd\u003eHardware test point for checking +24 V level.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eT 10 (Heat Sink)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTest Terminal\u003c\/td\u003e\n\u003ctd\u003eHardware test point for checking +48 V V2 level.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Verification:\u003c\/strong\u003e Ensure the AC supply selection switch (SW1) is set to match the incoming mains line voltage (115 V AC or 230 V AC) prior to applying power to prevent hardware damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Potential Hazard:\u003c\/strong\u003e Note that high voltage line potential is present across specific internal components of the board. Disconnect and lock out all primary power sources before servicing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEncoder Power Configuration:\u003c\/strong\u003e When utilizing an SDCS-CON-2 control board without an SDCS-IOB-3 I\/O board alongside a pulse encoder, hardware jumpers X3, X4, and X5 must be manually configured to the proper voltage level matching the encoder's specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMains Buffering Extension:\u003c\/strong\u003e To extend ride-through capability beyond the standard 30 ms buffer window, external capacitance modules can be wired directly to the designated X95 backup supply terminals.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668530786667,"sku":"SDCS-POW-1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-sdcs-pow-1-power-supply-puqzvm5eobm_9b57e26c-3abc-4142-951b-28cc758e25a8.jpg?v=1765532902","url":"https:\/\/www.plcprotech.com\/products\/abb-drives-sdcs-pow-1-dcs-500-power-supply-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}