{"product_id":"abb-dspa-110-57520001-p-masterview-800-display-processor","title":"ABB DSPA 110 57520001-P MasterView 800 Display Processor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDSPA 110\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Product ID:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e57520001-P\u003c\/strong\u003e) is a legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial display processor module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused in the ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAdvant Master \/ MasterView 800\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperator interface system.\u003c\/p\u003e\n\u003cp\u003eIt functions as a central computing and graphical processing unit within the Advant OCS architecture, responsible for rendering real-time process visualization and managing operator console communication. The module converts incoming control system telemetry into visual process displays for plant operation and monitoring.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDSPA 110\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for integration with ABB Advant Master systems used in large-scale industrial automation environments such as power plants, oil \u0026amp; gas facilities, and process control centers.\u003c\/p\u003e\n\u003cp\u003eThis module is classified as a legacy system component and is primarily used for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emaintenance, spare replacement, and system lifecycle extension\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edisplay processor board for Advant MasterView 800\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAdvant OCS control system architecture\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocess visualization processing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports operator console communication interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBoard-level\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecentral unit accessory module\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for legacy industrial control system maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with Advant Master system hardware racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStable operation in continuous industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDSPA 110\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e57520001-P\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003eAdvant OCS \/ MasterView 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDisplay Processor Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Role\u003c\/td\u003e\n\u003ctd\u003eCentral Unit \/ Operator Interface Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndustrial control visualization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e238.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e27.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e234.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eSystem Function and Operation\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDSPA 110 display processor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a graphical processing module within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAdvant Master control system\u003c\/strong\u003e. It receives real-time process data from core controllers and translates it into operator interface visualizations.\u003c\/p\u003e\n\u003cp\u003eThe module plays a key role in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcess monitoring display rendering\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperator console communication handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time telemetry visualization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem-level interface coordination within Advant MasterView 800\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt does not function as a standalone controller but as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esystem-level interface processor\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and Handling Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDSPA 110\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a board-level module designed for installation inside Advant system sub-racks.\u003c\/p\u003e\n\u003cp\u003eProper handling requirements include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUse grounded\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eESD protection equipment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eduring installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlign module carefully with backplane guide rails\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure proper seating to avoid backplane pin damage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure front panel screws to prevent vibration loosening\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIncorrect installation may lead to communication failure or backplane damage.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eElectrical and EMC Considerations\u003c\/h3\u003e\n\u003cp\u003eStable operation depends on correct grounding and shielding practices.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSub-rack chassis must be bonded to cabinet functional earth\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse low-impedance copper braid for grounding connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure all communication and video cables use shielded routing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain proper separation between signal and power wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProper EMC design ensures stable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edisplay rendering and communication performance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eThermal Management\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDSPA 110\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erelies on passive cooling through natural convection.\u003c\/p\u003e\n\u003cp\u003eTo maintain safe operation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain minimum 50 mm vertical airflow clearance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid overcrowding adjacent card slots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstall forced ventilation if cabinet temperature exceeds 45°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure consistent airflow across sub-rack assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDSPA 110\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eABB Advant Master control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMasterView 800 operator interface stations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas process control environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial DCS legacy system maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLong-life-cycle industrial automation infrastructures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProduct ID:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e57520001-P\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eABB Type Designation:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDSPA 110\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem: Advant Master \/ MasterView 800\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCategory: Legacy control system display processor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the DSPA 110 module?\u003c\/strong\u003e\u003cbr\u003eIt is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edisplay processor board\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused to render process visualization in ABB Advant Master systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan DSPA 110 be replaced with DSPB 120?\u003c\/strong\u003e\u003cbr\u003eNot directly. Although they are related, they differ in revision, memory configuration, and firmware compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module be hot-swapped?\u003c\/strong\u003e\u003cbr\u003eNo. Power must be isolated before removal to avoid backplane or system damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is this a legacy component?\u003c\/strong\u003e\u003cbr\u003eIt belongs to the ABB Advant MasterView 800 system, which is a previous-generation industrial control architecture still used in long-life installations.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668514238827,"sku":"DSCA120 57520001-P","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-dsca120-57520001-p-advanced-industrial-communications-board-gfigrvlx15v_a1a5e3cd-a789-48f7-846a-96cabda556f9.jpg?v=1765532616","url":"https:\/\/www.plcprotech.com\/products\/abb-dspa-110-57520001-p-masterview-800-display-processor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}