{"product_id":"abb-dsqc-351-3hne-00006-1-devicenet-interbus-gateway-module","title":"ABB DSQC 351 3HNE 00006-1 DeviceNet\/Interbus Gateway Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB DSQC 351 3HNE 00006-1\u003c\/strong\u003e is a specialized communication gateway module designed for industrial robot control systems, including the ABB IRC5 controller platform. It functions as a protocol translator interface between an internal DeviceNet network and an external Interbus fieldbus architecture. By enabling structured cyclic and acyclic data exchange between distinct fieldbus protocols, the module allows the main controller to integrate seamlessly into complex automated production lines and distributed process control environments.\u003c\/p\u003e\n\u003cp\u003eEngineered to fit into designated option expansion slots inside the IRC5 Control Module, the \u003cstrong\u003eABB DSQC 351\u003c\/strong\u003e connects to the internal DeviceNet master bus (such as the DSQC 603 master) and acts as an Interbus interface node. This setup enables real-time transmission of digital\/analog operational signals, safety interlocks, status monitoring messages, and supervisory control commands between the robot controller and higher-level PLCs or distributed I\/O systems across the plant floor.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Protocol Gateway Architecture:\u003c\/strong\u003e Enables seamless protocol conversion and signal mapping between DeviceNet and Interbus fieldbus networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIRC5 Controller Compatibility:\u003c\/strong\u003e Designed for mounting on internal mounting rails within the ABB IRC5 Control Module customer expansion area.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandardized Terminal Interfaces:\u003c\/strong\u003e Utilizes front-facing Phoenix Combicon pluggable connectors to facilitate reliable field wiring and quick module swapping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact DIN Rail Mounting:\u003c\/strong\u003e Features a snap-on mechanical retention mechanism with a manual release lever for secure panel assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Data Transmission:\u003c\/strong\u003e Supports rapid cyclic I\/O signal exchange and parameter mapping for precise industrial automation synchronization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentralized System Integration:\u003c\/strong\u003e Streamlines communication between the main robot controller, supervisory PLCs, and secondary automation equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomotive \u0026amp; Robotic Assembly Lines:\u003c\/strong\u003e Connects IRC5 robot controllers to main Interbus-based factory control networks for coordinated cell operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed Material Handling:\u003c\/strong\u003e Integrates robot controllers with supervisory PLCs, transfer lines, and conveyor tracking systems across long distances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging \u0026amp; Palletizing Cells:\u003c\/strong\u003e Facilitates multi-device communication between robot controllers, safety gateways, and external fieldbus networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Robot System Retrofits:\u003c\/strong\u003e Upgrades existing IRC5 robot cells to interface with legacy or specialized Interbus automation infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e3HNE 00006-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Designation\u003c\/td\u003e\n\u003ctd\u003eDSQC 351\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDeviceNet\/Interbus Gateway Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controller Platform\u003c\/td\u003e\n\u003ctd\u003eABB IRC5 Controller Series (M2004 Platform)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Communication Interface\u003c\/td\u003e\n\u003ctd\u003eDeviceNet \/ Interbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Location\u003c\/td\u003e\n\u003ctd\u003eIRC5 Control Module Customer Plate \/ Mounting Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection Type\u003c\/td\u003e\n\u003ctd\u003ePhoenix Combicon Pluggable Connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Capacity Limit\u003c\/td\u003e\n\u003ctd\u003eUp to 4 I\/O, Gateway, or Encoder units per IRC5 Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Bus Connection\u003c\/td\u003e\n\u003ctd\u003eConnects to internal IRC5 DeviceNet master communication harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Fieldbus Port\u003c\/td\u003e\n\u003ctd\u003eInterbus communication interface for external PLC or network connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhoenix Combicon Terminals\u003c\/td\u003e\n\u003ctd\u003ePluggable wiring terminals for field bus signals and auxiliary power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Verification:\u003c\/strong\u003e Switch off the main power switch on the IRC5 Control Module and ensure power to all connected external equipment is disconnected before opening the cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Attach an ESD grounding wrist strap to the designated grounding post on the computer unit inside the control cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Locate an available slot on the customer plate mounting rail inside the IRC5 Control Module. Snap the DSQC 351 module onto the rail until securely latched. Pull the release lever if necessary to facilitate proper alignment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Integration:\u003c\/strong\u003e Connect the internal DeviceNet communication harness and attach the external Interbus fieldbus cabling to the front Phoenix Combicon connectors. Ensure all pluggable terminal blocks are firmly seated and tightened.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Power Inspection:\u003c\/strong\u003e Verify signal polarity, ground connections, and fieldbus cabling integrity prior to re-energizing the controller cabinet.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Definition:\u003c\/strong\u003e Configure the new gateway node within the IRC5 system software (RobotStudio \/ RobotWare System Builder) to match the physical hardware configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal \u0026amp; Bus Mapping:\u003c\/strong\u003e Define I\/O signal mappings, station addresses, and baud rates according to the application's fieldbus requirements as detailed in the relevant ABB application manual for the bus system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup Settings:\u003c\/strong\u003e Perform a full system backup of the controller configuration parameters once communication between the DeviceNet and Interbus networks is verified.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53764889215339,"sku":"DSQC351 3HNE00006-1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/DSQC-351-3HNE-00006-1_001_1200x1200_3a33028b-b225-44da-8033-e33b1b0b0c5e.jpg?v=1787669116","url":"https:\/\/www.plcprotech.com\/products\/abb-dsqc-351-3hne-00006-1-devicenet-interbus-gateway-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}