{"product_id":"abb-el3060-easyline-continuous-gas-analyzer-for-hazardous-areas","title":"ABB EL3060 EasyLine Continuous Gas Analyzer for Hazardous Areas","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB EL3060\u003c\/strong\u003e is an EasyLine continuous gas analyzer designed for process gas measurement in potentially explosive atmospheres.\u003c\/p\u003e\n\u003cp\u003eThe system uses a flameproof EL3060-CU control unit that can accommodate an oxygen analyzer or thermal conductivity analyzer. The Uras26 infrared photometer is installed in a separate flameproof analyzer housing and communicates with the control unit.\u003c\/p\u003e\n\u003cp\u003eAvailable analyzer technologies include the \u003cstrong\u003eUras26\u003c\/strong\u003e infrared photometer, \u003cstrong\u003eMagnos206\u003c\/strong\u003e and \u003cstrong\u003eMagnos28\u003c\/strong\u003e paramagnetic oxygen analyzers, and \u003cstrong\u003eCaldos25\u003c\/strong\u003e and \u003cstrong\u003eCaldos27\u003c\/strong\u003e thermal conductivity analyzers. Compatible analyzer combinations enable measurement of multiple gas components within one EL3060 system.\u003c\/p\u003e\n\u003cp\u003eThe EL3060 is designed for hazardous-area applications and supports ATEX and IECEx configurations for Zone 1 installations. The front operator interface allows operation through the explosion-proof viewing window without opening the enclosure.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous gas analysis for hazardous-area applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEasyLine EL3060 modular analyzer architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlameproof EL3060-CU control unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for Zone 1 hazardous areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUras26 infrared photometer option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMagnos206 and Magnos28 oxygen analyzer options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCaldos25 and Caldos27 thermal conductivity analyzer options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement of flammable and non-flammable gases under specified conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperation through the explosion-proof front window\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP65 control-unit housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional Modbus and PROFIBUS communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEthernet interface with Modbus\/TCP capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable 0\/4 to 20 mA analog outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable digital inputs and outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional housing purge for applicable installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInternal flame barriers at gas connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous process gas concentration measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGas analysis in Zone 1 hazardous areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOxygen concentration monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInfrared measurement of gas components such as CO and CO2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal conductivity measurement of process gases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-component process gas analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous-area process monitoring and control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAnalyzer Options\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAnalyzer\u003c\/th\u003e\n\u003cth\u003eMeasurement Principle \/ Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUras26\u003c\/td\u003e\n\u003ctd\u003eInfrared photometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnos206\u003c\/td\u003e\n\u003ctd\u003eParamagnetic oxygen analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnos28\u003c\/td\u003e\n\u003ctd\u003eParamagnetic oxygen analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCaldos27\u003c\/td\u003e\n\u003ctd\u003eThermal conductivity analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCaldos25\u003c\/td\u003e\n\u003ctd\u003eThermal conductivity analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe EL3060-CU control unit can incorporate Magnos206, Magnos28, Caldos25, or Caldos27.\u003c\/p\u003e\n\u003cp\u003eThe Uras26 uses a separate flameproof analyzer unit. It may be combined with compatible oxygen or thermal conductivity measurement functions for multi-component analysis.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEL3060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eEasyLine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eContinuous Gas Analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eField-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended Environment\u003c\/td\u003e\n\u003ctd\u003ePotentially explosive atmospheres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Unit Housing\u003c\/td\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Unit Protection\u003c\/td\u003e\n\u003ctd\u003eEx d flameproof enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Housing Protection\u003c\/td\u003e\n\u003ctd\u003eEx e increased safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Unit IP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50 to 60 Hz, +\/-3 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power\u003c\/td\u003e\n\u003ctd\u003e187 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Battery\u003c\/td\u003e\n\u003ctd\u003eCR2032 type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCommunication and Outputs\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus\/TCP\u003c\/td\u003e\n\u003ctd\u003eAvailable through Ethernet; activation required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Module\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFIBUS Module\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e0\/4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Analog Output Setting\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Analog Output Load\u003c\/td\u003e\n\u003ctd\u003e750 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital I\/O\u003c\/td\u003e\n\u003ctd\u003eConfigurable according to installed I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Location\u003c\/td\u003e\n\u003ctd\u003eIndoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEL3060-CU Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e5 to 50 degC for specified metrological performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUras26 Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e5 to 45 degC for specified metrological performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport \/ Storage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eMaximum 75%, slight condensation allowed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Installation Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEL3060-CU Housing Protection\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUras26 Housing Protection\u003c\/td\u003e\n\u003ctd\u003eIP65 with O-ring \/ IP54 without O-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMechanical\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEL3060-CU Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUras26 Analyzer Unit Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEL3060-Uras26 Housing Diameter\u003c\/td\u003e\n\u003ctd\u003e240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEL3060-Uras26 Housing Length\u003c\/td\u003e\n\u003ctd\u003e406 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUras26 Required Opening Space\u003c\/td\u003e\n\u003ctd\u003eApprox. 800 mm total envelope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Connection Thread\u003c\/td\u003e\n\u003ctd\u003e1\/8 NPT female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHazardous-Area Certification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEL3060-CU\u003c\/td\u003e\n\u003ctd\u003eII 2G Ex db eb IIC T4 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEL3060-Uras26\u003c\/td\u003e\n\u003ctd\u003eII 2G Ex db IIC T4 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEL3060-CU ATEX Certificate\u003c\/td\u003e\n\u003ctd\u003eBVS 08 ATEX E 048 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEL3060-Uras26 ATEX Certificate\u003c\/td\u003e\n\u003ctd\u003eBVS 08 ATEX E 055 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEL3060-CU IECEx Certificate\u003c\/td\u003e\n\u003ctd\u003eIECEx BVS 13.0037X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEL3060-Uras26 IECEx Certificate\u003c\/td\u003e\n\u003ctd\u003eIECEx BVS 13.0056X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGas Connections\u003c\/h3\u003e\n\u003cp\u003eGas connections use internal flame barriers manufactured from rust-resistant and acid-resistant stainless steel 1.4571.\u003c\/p\u003e\n\u003cp\u003eThe standard connection interface uses \u003cstrong\u003e1\/8 NPT female threads\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eDepending on the analyzer configuration, connections may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSample gas inlet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSample gas outlet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHousing purge gas inlet and outlet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure sensor connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUras26 reference-gas connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the exact EL3060 analyzer configuration from the device data sheet before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm installed analyzer modules, measuring components, and measurement ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the analyzer indoors on a structure rated for the unit weight.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain adequate natural air circulation and avoid external heat sources.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect local potential equalization before other electrical connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify sample-gas pressure, flow, and dew-point conditions before commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the required external flow restrictor in the sample-gas line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCheck the sample-gas path for leak tightness before operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAllow the installed analyzer modules to complete their required warm-up period before applying normal sample gas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify calibration after transport and installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplacement and Configuration Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEL3060 identifies a configurable analyzer system rather than one fixed measuring configuration.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the analyzer data sheet before replacing an existing system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMatch installed analyzer modules, gas components, measuring ranges, I\/O configuration, and hazardous-area approvals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUras26 configurations require the corresponding EL3060 control unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional Modbus, PROFIBUS, pressure-sensor, purge, and I\/O configurations should not be assumed from the EL3060 model name alone.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53755642413419,"sku":"EL3060","price":30000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/EL3060_1200x1200_de78f3f7-84a4-4e57-9ef7-ca37bb8d1e04.jpg?v=1787398228","url":"https:\/\/www.plcprotech.com\/products\/abb-el3060-easyline-continuous-gas-analyzer-for-hazardous-areas","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}