{"product_id":"abb-fs300r12ke3-agdr-72c-industrial-igbt-and-gate-driver-assembly","title":"ABB FS300R12KE3\/AGDR-72C Industrial IGBT and Gate Driver Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB \u003cstrong\u003eFS300R12KE3 \/ AGDR-72C\u003c\/strong\u003e (Product ID: \u003cstrong\u003e68569541\u003c\/strong\u003e) is a high-power \u003cstrong\u003eIGBT module and gate driver assembly kit\u003c\/strong\u003e designed for industrial \u003cstrong\u003ethree-phase inverter systems\u003c\/strong\u003e and variable frequency drives.\u003c\/p\u003e\n\u003cp\u003eThis matched system combines the \u003cstrong\u003eInfineon TRENCHSTOP™ FS300R12KE3 IGBT3 power module\u003c\/strong\u003e with the \u003cstrong\u003eABB AGDR-72C gate driver board\u003c\/strong\u003e, delivering stable switching performance in demanding \u003cstrong\u003eindustrial motor control applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe assembly is widely used in \u003cstrong\u003eABB ACS800 drive platforms\u003c\/strong\u003e, where it handles high-current switching, real-time protection, and precise motor modulation. The \u003cstrong\u003eAGDR-72C driver board\u003c\/strong\u003e mounts directly onto the IGBT terminals, ensuring a low-inductance connection path that reduces switching noise and improves system reliability.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"width: 1181.8px;\" class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMatched \u003cstrong\u003eIGBT module + gate driver board kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFS300R12KE3 1200V TRENCHSTOP™ IGBT3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-performance \u003cstrong\u003eAGDR-72C gate driver board\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for \u003cstrong\u003eABB ACS800 industrial drive systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated \u003cstrong\u003edesaturation short-circuit protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh switching capability up to \u003cstrong\u003e20 kHz\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptimized low-inductance gate interface design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for high-power \u003cstrong\u003eindustrial inverter applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFS300R12KE3 \/ AGDR-72C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e68569541\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Code\u003c\/td\u003e\n\u003ctd\u003e3AUA0000109336\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eIGBT Module + Gate Driver Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIGBT Technology\u003c\/td\u003e\n\u003ctd\u003eInfineon \u003cstrong\u003eTRENCHSTOP™ IGBT3\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1200 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCollector Current\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e300 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Current\u003c\/td\u003e\n\u003ctd\u003e600 A (1 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1450 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003eUp to \u003cstrong\u003e20 kHz\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGate-Emitter Voltage\u003c\/td\u003e\n\u003ctd\u003e±20 V max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage\u003c\/td\u003e\n\u003ctd\u003e2500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSaturation Voltage\u003c\/td\u003e\n\u003ctd\u003e1.70–2.15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e21 × 175 × 152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany \/ Estonia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85359000 \/ 85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eSystem Function and Operation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFS300R12KE3 IGBT module\u003c\/strong\u003e performs high-power switching in inverter bridge circuits, while the \u003cstrong\u003eAGDR-72C gate driver board\u003c\/strong\u003e ensures accurate gate signal control and fast fault response.\u003c\/p\u003e\n\u003cp\u003eThe driver provides real-time protection functions including:\u003c\/p\u003e\n\u003cul style=\"width: 1181.8px;\" class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDesaturation monitoring\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShort-circuit detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSoft turn-off control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGate voltage supervision\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese functions protect the power stage during abnormal load or motor fault conditions in \u003cstrong\u003ehigh-power inverter systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eThermal Management and Installation\u003c\/h3\u003e\n\u003cp\u003eProper thermal design is critical for stable operation of the \u003cstrong\u003eIGBT power module assembly\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eBefore installation:\u003c\/p\u003e\n\u003cul style=\"width: 1181.8px;\" class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eClean heatsink and baseplate using non-residue solvent\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply uniform \u003cstrong\u003ethermal interface material (TIM)\u003c\/strong\u003e layer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure even pressure distribution during mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRecommended torque sequence:\u003c\/p\u003e\n\u003cul style=\"width: 1181.8px;\" class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInitial tightening: 2.0 Nm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFinal torque: 3.0–6.0 Nm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis ensures stable heat transfer under continuous high-load operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eRibbon Cable and System Compatibility\u003c\/h3\u003e\n\u003cp\u003eWhen replacing the \u003cstrong\u003eFS300R12KE3 \/ AGDR-72C assembly\u003c\/strong\u003e, it is recommended to replace associated control ribbon cables to ensure signal integrity.\u003c\/p\u003e\n\u003cp\u003eCommon configurations include:\u003c\/p\u003e\n\u003cul style=\"width: 1181.8px;\" class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eR7i frame systems: Code \u003cstrong\u003e68869625\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eR8i dual-IGBT systems: Code \u003cstrong\u003e68870089\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eR8i triple-IGBT systems: Code \u003cstrong\u003e68692172\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing aged ribbon cables may increase the risk of \u003cstrong\u003egate signal distortion and communication faults\u003c\/strong\u003e in the inverter stack.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eESD and Handling Requirements\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAGDR-72C gate driver board\u003c\/strong\u003e contains sensitive control electronics including optical isolation and high-density logic circuits.\u003c\/p\u003e\n\u003cp\u003eHandling requirements:\u003c\/p\u003e\n\u003cul style=\"width: 1181.8px;\" class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUse grounded \u003cstrong\u003eESD wrist protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDischarge DC bus capacitors before installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid direct contact with PCB components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify control rail stability before activation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIncorrect handling may cause permanent damage to the gate driver circuitry.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe ABB \u003cstrong\u003eFS300R12KE3 \/ AGDR-72C\u003c\/strong\u003e is used in:\u003c\/p\u003e\n\u003cul style=\"width: 1181.8px;\" class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eABB ACS800 industrial drive systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-power motor control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial frequency converters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWind power inverter systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeavy-duty automation drives\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial UPS power systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul style=\"width: 1181.8px;\" class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProduct ID: \u003cstrong\u003e68569541\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement Code: \u003cstrong\u003e3AUA0000109336\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType: \u003cstrong\u003eFS300R12KE3 \/ AGDR-72C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCategory: IGBT power module + gate driver kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHS Code: 85359000 \/ 85389091\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between AGDR-72C and AGDR-62C?\u003c\/strong\u003e\u003cbr\u003eThey differ in layout, gate resistance design, and thermal\/mechanical configuration. They are not universally interchangeable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this kit include protection functions?\u003c\/strong\u003e\u003cbr\u003eYes. The \u003cstrong\u003eAGDR-72C driver\u003c\/strong\u003e includes desaturation detection and fast fault shutdown mechanisms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan old ribbon cables be reused?\u003c\/strong\u003e\u003cbr\u003eIt is not recommended. Aging cables can introduce resistance drift and timing instability in gate signals.\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668514533739,"sku":"FS300R12KE3\/AGDR-72C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-fs300r12ke3-agdr-72c-igbt-module-kit-bbdzgj2qjua_c1729b66-646a-4b5c-a1f2-b884b8879c10.jpg?v=1765532628","url":"https:\/\/www.plcprotech.com\/products\/abb-fs300r12ke3-agdr-72c-industrial-igbt-and-gate-driver-assembly","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}