{"product_id":"abb-gjr2329800r0001-circuit-breaker","title":"ABB GJR2329800R0001 Circuit Breaker","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Designed for integration into demanding industrial power distribution and automation architectures, the \u003cstrong\u003eABB GJR2329800R0001\u003c\/strong\u003e delivers reliable overcurrent protection and circuit isolation. This heavy-duty protection component is engineered to safeguard downstream control circuits and automation hardware against thermal overloads and short-circuit faults. Featuring an industrial-grade housing, it ensures exceptional mechanical stability and thermal resilience in high-density control cabinet installations.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKey Technical Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDependable Circuit Isolation:\u003c\/strong\u003e Provides positive electrical disconnection to secure downstream PLC modules, power supplies, and sensitive electronic controllers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Industrial Enclosure:\u003c\/strong\u003e Designed to withstand vibration, heat, and physical stresses standard in heavy manufacturing environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard Panel Integration:\u003c\/strong\u003e Built to accommodate typical industrial control cabinet layouts with clean mounting alignment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Footprint:\u003c\/strong\u003e Maximizes panel space efficiency, supporting high-density side-by-side positioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eIndustrial control panel power distribution systems.\u003c\/li\u003e\n  \u003cli\u003eOvercurrent and fault protection for PLC, DCS, and SCADA control loops.\u003c\/li\u003e\n  \u003cli\u003eFactory automation environments and motor control centers (MCC).\u003c\/li\u003e\n  \u003cli\u003eDedicated power supply safety loops in machinery and manufacturing lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; color: #1a365d;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eArticle Number (SKU)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eGJR2329800R0001\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Classification\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCircuit Breaker\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e85371099\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eExport Control Classification (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    De-energize all power sources and confirm zero potential using a calibrated voltage testing instrument before performing any installation, maintenance, or wiring procedures. Work must be carried out by qualified electrical personnel in strict compliance with applicable local safety and industrial electrical codes.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eMount the circuit breaker securely onto the clean, debris-free DIN rail or designated chassis plate within the enclosure.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eEnsure all electrical terminations are clean and wire leads are stripped to the appropriate length to avoid exposed copper.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eTighten all connection terminals to the manufacturer's specified torque rating to prevent loose connections and localized thermal runaway.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701955424619,"sku":"GJR2329800R0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/gjr2329800r0001-dsllwyp5dew_3e020f85-8b80-4800-8935-501c662a7a05.jpg?v=1766478058","url":"https:\/\/www.plcprotech.com\/products\/abb-gjr2329800r0001-circuit-breaker","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}