{"product_id":"abb-gjr5251600r0101-procontic-cs31-icdt-08-b5-analog-input-module","title":"ABB GJR5251600R0101 Procontic CS31 ICDT 08 B5 Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eABB \u003cstrong\u003eGJR5251600R0101\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e \u003c\/strong\u003e(Type: \u003cstrong\u003eICDT 08 B5\u003c\/strong\u003e) is a versatile \u003cspan\u003e8-channel Analog Input Module\u003c\/span\u003e belonging to the \u003cspan\u003eProcontic CS31\u003c\/span\u003e remote I\/O family. This module acts as a remote station on the CS31 system bus, allowing for high-resolution data acquisition across long distances. It is designed for maximum flexibility, offering \u003cspan\u003e12-bit resolution\u003c\/span\u003e and channels that are configurable in pairs to support voltage, current, and temperature sensors (RTDs and Thermocouples), making it a comprehensive solution for complex process monitoring.\u003c\/p\u003e\n\u003ch3\u003eFunctional Intelligence \u0026amp; Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eICDT 08 B5\u003c\/span\u003e features an advanced internal control circuit that performs cyclic self-calibration to ensure long-term measurement stability. Configuration of the input types and the CS31 bus address is performed locally via \u003cspan\u003eDIL switches\u003c\/span\u003e. The module utilizes one address in the word input range, with each of the eight channels occupying 16 bits. To ensure system integrity, the CS31 system bus connection is \u003cspan\u003eelectrically isolated\u003c\/span\u003e from the internal module electronics and power supply.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrder Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGJR5251600R0101 \/ GJR5251666R1001\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eType Designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eICDT 08 B5 (ICDT08B5)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Channels (Configurable in pairs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Bits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Ranges\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 10V, \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 5V, \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 500mV, \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e 50mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Ranges\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0...20 mA, 4...20 mA (via external 250 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003eΩ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e shunt)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature Sensors\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePt100, Pt1000, Thermocouples (Types J, K, S)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBus Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCS31 System Bus (Electrically Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConversion Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1355 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord mathnormal\"\u003eμ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003es\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFront Panel \u0026amp; Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe module is equipped with an intuitive diagnostic interface on the front panel:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eChannel LEDs:\u003c\/span\u003e 8 green LEDs used for channel selection and detailed diagnosis, plus 8 green LEDs providing a rough visual representation of analog values.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eError Indicators:\u003c\/span\u003e A dedicated \u003cspan\u003eRed LED\u003c\/span\u003e for immediate error notification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTest Function:\u003c\/span\u003e A front-mounted \u003cspan\u003eTest Button\u003c\/span\u003e used to cycle through diagnostic information.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReference List:\u003c\/span\u003e A printed list of diagnostic codes located on the front panel for quick troubleshooting of sensor or bus faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSensor Compatibility:\u003c\/span\u003e Only \u003cspan\u003eelectrically isolated sensors\u003c\/span\u003e may be used with the ICDT 08 B5. If using non-isolated sensors, external signal isolators must be installed to prevent ground loops that could damage the 12-bit conversion circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCurrent Measurement:\u003c\/span\u003e To measure 0...20 mA or 4...20 mA signals, the module must be configured for the 5V range and an \u003cspan\u003eexternal 250 \u003cspan class=\"math-inline\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003eΩ\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e precision shunt\u003c\/span\u003e must be installed across the input terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting:\u003c\/span\u003e The unit is designed for industrial flexibility; it can be snapped onto a \u003cspan\u003e15-mm-high DIN rail\u003c\/span\u003e or fastened directly to a mounting plate using four screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfiguration:\u003c\/span\u003e Before commissioning, verify that the DIL switches match the intended sensor types for each pair of channels. Changing DIL switch settings typically requires a module power cycle to register the new configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eABB ICDT 08 B5\u003c\/span\u003e provides a high-density, multifunctional analog interface that reduces the need for multiple specialized modules. Its built-in linearization for Pt100\/Pt1000 and standard thermocouples simplifies PLC programming by providing direct, scaled values to the CS31 master. For B2B procurement and maintenance, the \u003cspan\u003eGJR5251600R0101\u003c\/span\u003e is a critical component for maintaining the accuracy and reliability of legacy Procontic CS31 installations, offering a robust bridge between field instrumentation and the central control system.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701959455083,"sku":"GJR5251600R0101","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/gjr5251600r0101-leu5ypuwbgz_d2e0c6cf-4553-4e35-b6ba-6ef2ff3b67e4.jpg?v=1766478181","url":"https:\/\/www.plcprotech.com\/products\/abb-gjr5251600r0101-procontic-cs31-icdt-08-b5-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}