{"product_id":"abb-hesg448230r1-g-216ea61b-reg-216-analogue-i-p-unit","title":"ABB HESG448230R1\/G 216EA61B REG 216 Analogue I\/P Unit","description":"\u003cp\u003e\u003cstrong\u003eABB HESG448230R1\/G 216EA61B\u003c\/strong\u003e is an analogue input unit designed for the RE. 216 digital protection and control system. The unit receives analogue measured variables from the 216GW61 input transformer module, digitises them via an A\/D converter, and transfers the digitised signal data to the system's B448C parallel bus.\u003c\/p\u003e\n\u003ch3\u003eOverview and System Integration\u003c\/h3\u003e\n\u003cp\u003eThe module functions as a core measurement acquisition unit within the RE. 216 hardware architecture. Operating with an internal supply voltage of 5 V derived from the rack's main 24 V DC auxiliary supply, the \u003cstrong\u003eABB HESG448230R1\/G 216EA61B\u003c\/strong\u003e processes analogue input voltages ranging from -40 V to +40 V. Digitised measurement channels are subsequently assigned to active protection and control functions stored within the processing unit via the user interface software.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for integration within the RE. 216 system equipment rack.\u003c\/li\u003e\n\u003cli\u003eAccepts voltage inputs from primary matching instrument transformer modules.\u003c\/li\u003e\n\u003cli\u003eIntegrated microprocessor-based preprocessing for measured analogue variables.\u003c\/li\u003e\n\u003cli\u003eFront-panel status indication LEDs for diagnostic and operational monitoring.\u003c\/li\u003e\n\u003cli\u003eFront-accessible PASSIVE and RESET shorting pin sockets for hardware control.\u003c\/li\u003e\n\u003cli\u003eHigh-density bus interface connecting directly to the rear B448C parallel bus.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDigital generator protection systems (REG 216 \/ REG 216 Compact).\u003c\/li\u003e\n\u003cli\u003eDigital control and data acquisition units (REC 216) in medium and high-voltage substations.\u003c\/li\u003e\n\u003cli\u003eSignal conditioning and A\/D conversion for primary system current and voltage measurement circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHESG448230R1\/G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e216EA61B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalogue I\/P Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRE. 216 (REG 216 \/ REC 216)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 analogue I\/P channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalogue Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 V to +40 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Auxiliary Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V DC (derived from 24 V DC main auxiliary supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 standard divisions (2T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80C186\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 kByte DPM\/RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgram Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128 kByte EPROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 kByte RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kByte EEPROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Controls \u0026amp; Diagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLEDs: ALARM (red), MST (yellow), RUN (green); Sockets: PASSIVE, RESET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector \"a\" (Upper)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalogue Measurement Channels CH01...CH12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector \"b\" (Lower)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalogue Measurement Channels CH13...CH24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePASSIVE Socket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShorting pin socket; blocks the A\/D converter and stops data transfer to the bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRESET Socket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShorting pin socket; restarts program execution and reinitialises module tables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Interruption\u003c\/strong\u003e: The module must only be inserted into or removed from the equipment rack when the auxiliary power supply is completely switched off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Mounting\u003c\/strong\u003e: Fits into standard slots reserved for analogue input units within the 216MB66 equipment rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Cabling\u003c\/strong\u003e: Interfacing with the matching input transformer module (e.g., 216GW61) is accomplished using the designated standard system cables connected to the rear connector positions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Measuring channels are mapped to active protection functions using a PC-based user program connected to the processor unit's RS-232\/RS-423 front interface.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668614115691,"sku":"HESG448230R1\/G 216EA61B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-hesg448230r1-g-216ea61b-analog-input-board-dvlv5lbbxw0_321cf969-0913-4d3a-b13b-bb141272b98c.jpg?v=1765535601","url":"https:\/\/www.plcprotech.com\/products\/abb-hesg448230r1-g-216ea61b-reg-216-analogue-i-p-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}