{"product_id":"abb-hiee300890r0001-ld-mub-01-measurement-unit-board","title":"ABB HIEE300890R0001 LD MUB-01 Measurement Unit Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB HIEE300890R0001\u003c\/strong\u003e is a specialized measurement unit board designated as \u003cstrong\u003eLD MUB-01\u003c\/strong\u003e, engineered for integration within high-power medium voltage AC drives. As an essential internal control and monitoring component, the board interfaces directly with drive diagnostics and feedback loops to ensure precise operations. This measurement unit board functions primarily as a designated spare part to sustain the operational integrity, electrical monitoring, and system safety profiles of specialized ABB drive architectures. The board is fully compatible with specialized medium voltage drive topologies, specifically serving as a direct replacement component for \u003cstrong\u003eACS 5000 Water Cooled\u003c\/strong\u003e and \u003cstrong\u003eACS 6000\u003c\/strong\u003e drive systems.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides direct electrical measurement and signal interface capabilities within medium voltage drive systems.\u003c\/li\u003e\n\u003cli\u003eDirect replacement design for obsolete part number \u003cstrong\u003e61320938\u003c\/strong\u003e to ensure continuous fleet sustainability.\u003c\/li\u003e\n\u003cli\u003eEngineered to slide into standard internal control card slots within specialized drive enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eACS 5000 Water Cooled\u003c\/strong\u003e medium voltage AC drives for process industries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eACS 6000\u003c\/strong\u003e special purpose medium voltage AC drives used in heavy industrial applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHIEE300890R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eABB Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLD MUB-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85049099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitzerland (CH), Finland (FI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.251 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge (ESD) Protection:\u003c\/strong\u003e The board contains sensitive electronic components. Technicians must wear a grounded ESD wrist strap during handling and installation to prevent static damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower De-energization:\u003c\/strong\u003e Ensure that the medium voltage AC drive is fully isolated, locked out, and all internal DC bus capacitors are completely discharged before accessing the control section or removing the old board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure Mounting:\u003c\/strong\u003e Align the board precisely with the internal chassis card guides and secure all retention screws to guarantee proper grounding and vibration resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Connections:\u003c\/strong\u003e Carefully verify the orientation and seating of all ribbon cables and multi-pin connectors linked to the board prior to re-energizing the drive.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668613362027,"sku":"HIEE300890R0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-hiee300890r0001-uac383ae01-binary-input-5eirwcbd31u_e065cd72-0d8e-49f3-9d5f-fb1d6e5534d8.jpg?v=1765535573","url":"https:\/\/www.plcprotech.com\/products\/abb-hiee300890r0001-ld-mub-01-measurement-unit-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}