{"product_id":"abb-icmk14f1-1sbp260050r1001-ac-31-extensible-remote-unit","title":"ABB ICMK14F1 1SBP260050R1001 AC 31 Extensible Remote Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB ICMK 14 F1\u003c\/strong\u003e, product ID \u003cstrong\u003e1SBP260050R1001\u003c\/strong\u003e, is an extensible remote unit engineered for the Advant Controller 31 (AC 31) automation system. It serves as a decentralized connection point on the CS 31 master\/slave bus, enabling localized distributed applications close to sensors and actuators. The unit features 8 built-in isolated binary inputs and 6 relay outputs. Designed for modular flexibility, it supports the local addition of up to 6 binary or analog extension units to expand system I\/O capabilities up to a maximum of 8 analog input channels and 8 analog output channels.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDecoupled architecture supporting up to 6 local binary or analog extension units.\u003c\/li\u003e\n\u003cli\u003eIntegrated CS 31 multipoint serial interface for high-speed fieldbus communication.\u003c\/li\u003e\n\u003cli\u003eConfigurable input processing accommodating both PNP and NPN sensor types.\u003c\/li\u003e\n\u003cli\u003eElectrical isolation between inputs and internal electronics up to 1500 V a.c..\u003c\/li\u003e\n\u003cli\u003eDirect diagnostics via localized status visualization LED indicators (POWER, RUN, ERR) on the front panel.\u003c\/li\u003e\n\u003cli\u003eBuilt-in rotary selector switches on the front panel for manual decade and unit addressing on the bus.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed machine control networks.\u003c\/li\u003e\n\u003cli\u003eIndustrial manufacturing processes (e.g., ceramic, floor board, and electrical contactor assembly lines).\u003c\/li\u003e\n\u003cli\u003eWater treatment plant automation.\u003c\/li\u003e\n\u003cli\u003eInfrastructure management including building power and tunnel ventilation systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eReference Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eICMK 14 F1 24VDC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1SBP260050R1001\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtensible remote unit, features 8 isolated inputs (24 V d.c.) and 6 relay outputs (250 V a.c. \/ 2 A), powered by 24 V d.c. supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eICMK 14 F1 120\/230VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1SBP260051R1001\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtensible remote unit, features 8 isolated inputs (24 V d.c.) and 6 relay outputs (250 V a.c. \/ 2 A), includes an integrated 24 V d.c. power supply output for sensor inputs, powered by 120 \/ 230 V a.c. supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eICMK 14 N1 24VDC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1SBP260052R1001\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtensible remote unit, features 8 isolated inputs (24 V d.c.) and 6 transistor outputs (24 V d.c. \/ 0.5 A), powered by 24 V d.c. supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Distinctions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eICMK 14 F1 24VDC:\u003c\/strong\u003e Standard direct current (d.c.) power supply version paired with heavy-duty relay switching outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eICMK 14 F1 120\/230VAC:\u003c\/strong\u003e Alternate current (a.c.) power supply version equipped with an auxiliary 24 V d.c. loop power output to energize field sensors directly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eICMK 14 N1 24VDC:\u003c\/strong\u003e Standard direct current (d.c.) power supply version utilizing solid-state transistor outputs, engineered for high-frequency and rapid switching operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eICMK 14 F1 24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SBP260050R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtensible Remote Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Power Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V d.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdmissible Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 to 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption (Unit Alone)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption (Max Configuration)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePolarity Reversal Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Binary Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 V a.c. (inputs \/ electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePNP and NPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V d.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal 0 Voltage (IEC 1131-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to +5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal 1 Voltage (IEC 1131-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+15 to +30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current (at 24 V d.c.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 mA (Inputs Ixx.02 to Ixx.07); 9 mA (Inputs Ixx.00 and Ixx.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Filtering Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 Vrms for 1 minute (outputs \/ electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Charging Current (Direct Current)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A at 24 V d.c. (resistive load); 2 A (L\/R = 20 ms); 1 A (L\/R = 30 ms); 0.6 A (L\/R = 40 ms); 0.35 A (L\/R = 60 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Charging Current (Alternate Current)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A at 24 to 230 V a.c. (AC-1); 0.5 A at 24 to 230 V a.c. (AC-15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Charging Current Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 x 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Cut-off Values\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mA under 12 V d.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (UL B300)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A under 120 V a.c.; 1.5 A under 250 V a.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Commons\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (arranged as 2+4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 Hz (resistive loads); \u0026lt; 0.2 Hz (inductive\/lamp loads)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB CS 31 (master\/slave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Interface Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS 485 multipoint serial interface (half-duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Transmission Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187.5 kBauds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Transmission Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCRC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Horizontal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 degC to +55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (Vertical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 degC to +40 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +75 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnshielded Cable Length Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 m (inputs); 150 m (outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShielded Cable Length Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 m (inputs); 500 m (outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the unit to a standard 35 mm DIN rail using the integrated mounting lock, or use 4 mm diameter (M4) screws for panel mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Utilize removable terminal blocks supporting a maximum wire cross-section of 2.5 mm². Tighten connection screws to an indicative torque of 0.5 Nm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarthing:\u003c\/strong\u003e Ensure robust earthing by connecting the rigid or multi-conductor AWG 14 wire to the unit's grounding plate fixture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Termination:\u003c\/strong\u003e Connect a 120 Ohm, 0.25 Watt line termination resistor across each extremity of the RS 485 CS 31 bus network.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668629418347,"sku":"ICMK14F1 1SBP260050R1001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-icmk14f1-1sbp260050r1001-extensible-remote-unit-eb1hkjt30il_44bbe3c8-eebe-45b0-bd53-2e8ae0a93c12.jpg?v=1765536107","url":"https:\/\/www.plcprotech.com\/products\/abb-icmk14f1-1sbp260050r1001-ac-31-extensible-remote-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}