{"product_id":"abb-imasi13-symphony-harmony-analog-input-module","title":"ABB IMASI13 Symphony Harmony Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB IMASI13\u003c\/strong\u003e is a high-density, high-resolution analog input module designed for the Symphony Enterprise Management and Control System and fully compatible with legacy INFI 90 OPEN Strategic Enterprise Management Systems. Operating as an intelligent component within the Harmony rack I\/O architecture, the \u003cstrong\u003eIMASI13\u003c\/strong\u003e interfaces up to 16 independently configured process channels to a Harmony area controller via a parallel, synchronous I\/O expander bus.\u003c\/p\u003e\n\u003cp\u003eThe primary purpose of the \u003cstrong\u003eIMASI13\u003c\/strong\u003e is to condition, isolate, and digitize raw plant signals, incorporating dedicated delta-sigma analog-to-digital converters per channel to deliver an exceptional conversion resolution of 24 bits. It acts as a direct, drop-in replacement for the IMASI03 module, requiring only slight specification updates within function code 216 to accommodate enhanced resolution options. The module eliminates manual calibration overhead by recording factory offset, gain, and nonlinearity coefficients in onboard nonvolatile memory, executing continuous automatic recalibration during normal operation to neutralize component aging and temperature drift.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 analog input channels, each featuring a dedicated analog-to-digital converter providing true channel-to-channel and channel-to-logic isolation.\u003c\/li\u003e\n\u003cli\u003ehigh-resolution 24-bit delta-sigma conversion architecture with a total conversion rate of 180 msec for all 16 channels.\u003c\/li\u003e\n\u003cli\u003eOnboard microcontroller independently executes error compensation, adjustment algorithms, and engineering units conversion, offloading key operations from the primary controller.\u003c\/li\u003e\n\u003cli\u003eFlexible per-channel programming via function code 216, allowing a diverse mix of low-level voltage, high-level voltage, current, and resistance sensors on a single module.\u003c\/li\u003e\n\u003cli\u003eAdvanced built-in diagnostics that run continuously during startup, reset, and execution phases to monitor memory checksums, watchdog timers, and circuit integrity.\u003c\/li\u003e\n\u003cli\u003eComprehensive open input detection across active low-level voltage, thermocouple, current, and RTD loops to immediately flag field wire or termination cable breaks.\u003c\/li\u003e\n\u003cli\u003eIntegrated cold junction compensation utilising onboard RTD reference networks embedded directly in the associated field termination hardware.\u003c\/li\u003e\n\u003cli\u003eLive-insertion capability (hot-swapping) allows removal or installation without interrupting system logic power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThermocouple temperature monitoring and thermal profiling in power generation facilities.\u003c\/li\u003e\n\u003cli\u003eRTD-based cryogenic and high-precision temperature control loops in chemical processing plants.\u003c\/li\u003e\n\u003cli\u003eHigh-level voltage tracking (-10 VDC to +10 VDC) for heavy machinery position and speed instrumentation.\u003c\/li\u003e\n\u003cli\u003eStandard 4 to 20 mA process loop monitoring for pressure, flow, and level transmitters.\u003c\/li\u003e\n\u003cli\u003eMillivolt-level sensor interfaces for specialized metallurgical and laboratory process units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProperty\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCharacteristic \/ Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB Automation Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 independently configured channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA-to-D Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConversion Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180 msec for all 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VDC at 500 mA typical, maximum 750 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI for circuits above 150V, II for circuits below 150V (IEC 61010-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermocouple Input Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE, J, K, L, N (14 AWG), N (28 AWG), R, S, T, U, Chinese Type E, Chinese Type S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3-Wire RTD Input Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ohm platinum (U.S. Lab. Standard, U.S. Industry Standard, European Standard), 120 ohm nickel, 10 ohm copper, Chinese 53 ohm copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMillivolt Input Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-100 mV to +100 mV, 0 to 100 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh Level Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 5 VDC, 0 to 5 VDC, 0 to 10 VDC, -10 VDC to +10 VDC (or user-specified within -10 and +10 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Input Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA (system or external power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance (mV, TC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MOhm minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance (V, mA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kOhm minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.02% of full scale range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh Level Voltage Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.04% of full scale range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Level Voltage Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.03% of full scale range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05% of full scale range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Effect (0 to 70 degC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.003% of full scale range per degree C maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Settling Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 seconds to within 1% after full scale step change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCold Junction Reference Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e$\\pm0.5$ degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware Linearization Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e$\\pm0.1$ degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 VDC \/ V_RMS at 60 Hz (IEC 61010-1, IEC 60255-5, IEC 60060)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MOhm minimum at 100\/500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 kVrms\/1 min. or 1.95 kV DC\/1 min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpulse Voltage (1.2\/50 uS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+2.55 kVp (Common Mode), +1 kVp (Normal Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Mode Rejection (50-60 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-80 dB minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Rejection (50-60 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-120 dB minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak or Continuous Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 VDC absolute maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact: $\\pm6$ kV, Air: $\\pm8$ kV (IEC 61000-4-2, EN 61000-4-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (Operating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 degC to 70 degC (32 degF to 158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% up to 55 degC, 5% to 45% at 70 degC (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAltitude Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSea level to 3 km (1.86 miles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir Quality\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNoncorrosive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Slot Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOccupies a single slot in a standard module mounting unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe backplane interface provides electrical connections for input power, expander bus tracking, and plant process loops via three defined edge connectors:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupply voltage inputs (+5 VDC logic power from the MMU backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/O Expander Bus interface connection (Synchronous parallel communication with the controller)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Signal Connections (Interfaces process inputs from the NKAS01\/NKAS11 cabling system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Safety:\u003c\/strong\u003e Always attach a grounded static wrist strap before sliding the module out of its protective shielding bag or working around the circuit card assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Segmentation:\u003c\/strong\u003e Confirm that a 12-position dipshunt is correctly nested within the backplane socket on the Module Mounting Unit (MMU) to bind communication lines between the rack controller and the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Configuration:\u003c\/strong\u003e Define the exact binary hardware address utilizing the rightmost six positions (positions 3 through 8) of the S1 dipswitch. Verify positions 1 and 2 are firmly closed (set to zero) for correct module operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Settings:\u003c\/strong\u003e Modify the onboard hardware configuration jumper blocks (J1 through J16) to align with specific channel-by-channel requirements (millivolt, thermocouple, RTD, voltage, or current) as designated in the system software configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Installation:\u003c\/strong\u003e Carefully glide the printed circuit card along the plastic slot channels of the MMU frame. Secure the unit using the front-panel captive screws by twisting them a half-turn until the latch slots line up vertically.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Complies with Generic Immunity Standard EN50082-2 (Industrial Environment), Generic Emission Standard EN50081-2 (Industrial Environment), and Low Voltage Directive 73\/23\/EEC (via EN61010-1 safety metrics).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668527411563,"sku":"IMASI13","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-imasi13-analog-input-module-f0ezihbkv0l_4431c031-4fcc-4def-bcd3-147c11354be1.jpg?v=1765532852","url":"https:\/\/www.plcprotech.com\/products\/abb-imasi13-symphony-harmony-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}