{"product_id":"abb-imasm01-bailey-infi-90-analog-slave-module","title":"ABB IMASM01 Bailey Infi 90 Analog Slave Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB IMASM01\u003c\/strong\u003e Analog Slave Module is a high-level analog input interface designed for use within the INFI 90 Process Management System. Functioning in conjunction with an Analog Master Module such as the \u003cstrong\u003eIMAMM03\u003c\/strong\u003e, the \u003cstrong\u003eIMASM01\u003c\/strong\u003e conditions and routes process field analog input signals to the master module via the slave expander bus.\u003c\/p\u003e\n\u003cp\u003eThe module interfaces up to 16 individual high-level analog signals divided into two distinct input groups of eight channels each. Field process signals are directed to the module through system cable connections to associated termination units or modules, such as the NTAI05 or NIAI04. Onboard group address switches and enable\/disable jumpers allow flexible system integration and address selection within a Process Control Unit (PCU) rack.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterfaces up to 16 high-level analog input channels across two independent 8-channel input groups.\u003c\/li\u003e\n\u003cli\u003eDirect compatibility with the \u003cstrong\u003eIMAMM03\u003c\/strong\u003e Analog Master Module via the slave expander bus.\u003c\/li\u003e\n\u003cli\u003eOnboard dipswitches for setting independent group addresses (0 to 7) for each 8-channel group.\u003c\/li\u003e\n\u003cli\u003eDedicated enable\/disable jumpers for each input group to prevent address conflicts.\u003c\/li\u003e\n\u003cli\u003eIntegrated input filtering circuits providing normal mode and common mode noise rejection.\u003c\/li\u003e\n\u003cli\u003eSupports live insertion and removal without powering down the entire control system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial DCS process control and monitoring in power generation, chemical, and refining plants.\u003c\/li\u003e\n\u003cli\u003eHigh-level analog signal interface for transmitters and field devices (4 to 20 mA and 0 to 10 VDC loops).\u003c\/li\u003e\n\u003cli\u003eInput expansion for INFI 90 Process Control Units (PCUs).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB \/ Elsag Bailey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIMASM01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh Level Analog Slave Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eINFI 90 Process Management System (with IMAMM03 Master)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 high level (15 when used with NIAI04 Termination Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels per Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 channels per group (2 groups total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 5 VDC, 0 to 5 VDC, 0 to 10 VDC, -10 to +10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;1 Mohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Mode Rejection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-60 db at 60 HZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Rejection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-50 db at 60 HZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements (Voltage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 VDC (+\/-5%), +15 VDC (-2.5%, +5%), -15 VDC (+2.5%, -5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent (Maximum)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 mA (+5 VDC), 80 mA (+15 VDC), 40 mA (-15 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation (Maximum)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.055 watts (+5 VDC), 1.2 watts (+15 VDC), 0.06 watts (-15 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Slot Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 slot in standard INFI 90 Module Mounting Unit (MMU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 70 degC (32 to 158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 95% up to 55 degC (131 degF) noncondensing; 0% to 45% at 70 degC (158 degF) noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAltitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSea level to 3 Km (1.86 miles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir Quality\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNoncorrosive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTermination Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNTAI05, NIAI04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin \/ Port\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP1 Edge Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnects to logic power (+5 VDC, +15 VDC, -15 VDC) on the MMU backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP2 Edge Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnects to the slave expander bus for communication and analog bus routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 Edge Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterfaces to field input wiring via termination unit\/module cables (NKTU01\/02 or NKTM01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Always wear a grounded wrist strap and handle the card by its edges when inserting or removing it from the rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Configuration:\u003c\/strong\u003e Set group address dipswitches S1 (inputs 9-16) and S2 (inputs 1-8) to unique group addresses (0 to 7) prior to installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroup Enable\/Disable:\u003c\/strong\u003e Set jumpers JP1 (inputs 1-8) and JP2 (inputs 9-16) to position B to enable a group, or position A to disable an unused group to prevent dual-addressing conflicts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlave Expander Bus:\u003c\/strong\u003e Ensure 12-strap dipshunts are installed in the MMU backplane sockets between the master module and associated slave modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Mounting:\u003c\/strong\u003e Align the module card edges with the guide rails in the Module Mounting Unit (MMU) slot and slide in until flush with the rack frame; tighten the two captive faceplate screws.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA certified for use as process control equipment in an ordinary (nonhazardous) location.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668624535915,"sku":"IMASM01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-imasm01-analog-input-board-rw4tbpccdk0_40ab92bf-ddff-4568-827f-ba33873b7f4a.jpg?v=1765535930","url":"https:\/\/www.plcprotech.com\/products\/abb-imasm01-bailey-infi-90-analog-slave-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}