{"product_id":"abb-imdsm05-bailey-infi-90-digital-i-o-slave-module","title":"ABB IMDSM05 Bailey INFI 90 Digital I\/O Slave Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003eABB IMDSM05\u003c\/b\u003e Digital I\/O Slave Module is a digital input\/output interface for process field signals within the INFI 90 Process Management System. It brings up to 16 digital signals into master modules—such as the Multi-Function Processor (MFP), Multi-Function Controller (MFC), or Logic Master Module (LMM)—for monitoring, and transmits digital control signals to process field control devices like relays, lamps, contacts, switches, or solenoids. The module also handles signal transfers between master modules and Digital Logic Stations (NDLS02).\u003c\/p\u003e\n\n\u003cp\u003eThe module consists of a single printed circuit board occupying one slot in a Module Mounting Unit (MMU). It contains 16 I\/O circuits divided into two independent groups of eight (Group A and Group B). Twelve I\/O circuits are individually isolated from each other, while the remaining two pairs share positive common input lines.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterfaces up to 16 digital I\/O field signals (24 VDC) to INFI 90 master modules over the slave expander bus.\u003c\/li\u003e\n\u003cli\u003eTwo independent, identical 8-point I\/O groups (Group A and Group B) configurable for input or output operation.\u003c\/li\u003e\n\u003cli\u003eIndividual module jumpers configurable for non-isolated operation with read-back capabilities or two-wire isolated output operation.\u003c\/li\u003e\n\u003cli\u003eFront panel LED status indicators for visual indication of digital input\/output states and module status.\u003c\/li\u003e\n\u003cli\u003eBuilt-in default value settings for output groups during loss of communication with the master module.\u003c\/li\u003e\n\u003cli\u003esemi-custom gate array universal slave expander bus interface for address detection, function code decoding, and signal filtering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterfacing digital field switches, contacts, relays, and solenoids to DCS master controllers.\u003c\/li\u003e\n\u003cli\u003eProcess control monitoring and discrete digital actuation in INFI 90 systems.\u003c\/li\u003e\n\u003cli\u003eInterfacing INFI 90 master processors with Digital Logic Stations (NDLS02).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eABB \/ Elsag Bailey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eLogic Power Supply\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 VDC (+\/- 5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eI\/O Power Supply\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e+24 VDC (21.6 VDC to 27.0 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e5 VDC Current Consumption\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e757 mA typical \/ 867 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePower Dissipation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 W (logic) \/ 5.0 W (I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eNumber of Channels\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e16 digital I\/O circuits (Group A: 8, Group B: 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eInput High Level Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eV I\/O 4.0 Volts minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eInput Low Level Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eV I\/O 16.5 Volts maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eInput Low Level Current\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-11.8 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOutput Low Level Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOutput High Level Current\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e100 uA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOutput Sink Current\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e120 mA (10 V typical, 2.0 V maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eInput Propagation Delay\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eLow to high: 50 usec typical \/ High to low: 25 usec typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOutput Propagation Delay\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eLow to high: 25 usec typical \/ High to low: 100 usec typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eIsolation Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e150 V RMS Channel-to-channel \/ 150 V RMS Channel-to-logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSurge Withstand Capability\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eMeets IEEE Standard 472-1974 on input and output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eField Wiring Size\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 12 AWG to NTDI01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMounting\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eOccupies 1 slot in INFI 90 Module Mounting Unit (MMU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAmbient Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 70 degC (32 to 158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRelative Humidity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 95% up to 55 degC (non-condensing), 0% to 45% at 70 degC (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAtmospheric Pressure\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSea level to 3 km (1.86 miles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAir Quality\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eNoncorrosive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eP1 Pin 1, 2\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 VDC Logic Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eP1 Pin 5, 6\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eP1 Pin 3, 4, 7, 8, 9, 10, 11, 12\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eNC (Not Connected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eP2 Pin 1 to 8\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSlave Expander Bus Data Lines (Data 0 to Data 7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eP2 Pin 9\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSlave Expander Bus Clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eP2 Pin 10\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSlave Expander Bus Sync\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eP2 Pin 11\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e+5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eP2 Pin 12\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eGND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eP3 Group A Pins A\/1 to H\/J\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O Signals Group A Points 1 to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eP3 Group B Pins K\/9 to S\/8\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O Signals Group B Points 1 to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse grounded static dissipative wrist straps and anti-static procedures when handling the module to protect electrostatic sensitive devices.\u003c\/li\u003e\n\u003cli\u003eConfigure the 8-position slave address dipswitch (S1) to match the address defined in Function Code 84 Specification 1 before inserting the module.\u003c\/li\u003e\n\u003cli\u003eSet master selection jumpers J17 and J18 to positions 1-2 for LMM01 operation, or positions 2-3 for MFP, MFC, or LMM02 operation.\u003c\/li\u003e\n\u003cli\u003eSet digital I\/O jumpers J1 to J16 to positions 1-2 for inputs or normal outputs, or positions 2-3 for two-wire isolated output operation.\u003c\/li\u003e\n\u003cli\u003eVerify that a dipshunt is installed in the slave expander bus socket on the MMU backplane between the slave and master modules.\u003c\/li\u003e\n\u003cli\u003eDisconnect power before installing dipshunts for slave modules on the MMU backplane.\u003c\/li\u003e\n\u003cli\u003eSlide the module along the plastic guide rails of the MMU until the front panel is flush with the frame, then tighten the two captive retaining screws.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA Certified for use as process control equipment in an ordinary (non-hazardous) location.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668620407147,"sku":"IMDSM05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-imdsm05-bailey-infi-90-digital-i-o-module-1fezcymdmy2_86359998-47ad-4e9f-9dd2-fed995df3dd7.jpg?v=1765535766","url":"https:\/\/www.plcprotech.com\/products\/abb-imdsm05-bailey-infi-90-digital-i-o-slave-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}