{"product_id":"abb-imsed01-harmony-sequence-of-events-digital-input-module","title":"ABB IMSED01 Harmony Sequence of Events Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB IMSED01\u003c\/strong\u003e Harmony Sequence of Events Digital Input Module provides distributed event monitoring, recording, and reporting capabilities for the Symphony Enterprise Management and Control System. It monitors digital signal transitions from either on to off or from off to on. These digital state transitions are collected at the Harmony Control Unit (HCU) level and forwarded to the INSEM01 Master module for time-stamping, sorting, and storage in an internal database. The module processes up to 16 digital field inputs for its designated Harmony controller. It does not process time synchronization link information directly, relying instead on its controller to interface configuration and access data. The module consists of a single printed circuit board that installs inside a dedicated slot within a module mounting unit.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProcesses up to 16 digital field inputs for the Harmony controller.\u003c\/li\u003e\n  \u003cli\u003eInterfaces via function code 242 (SOE digital event interface) to configure and access module input channels.\u003c\/li\u003e\n  \u003cli\u003eSupports up to 63 modules operating concurrently on a single I\/O expander bus segment along with one IMSET01 module.\u003c\/li\u003e\n  \u003cli\u003eConnects to an NTDI01 termination unit via cable for external process field wiring terminations.\u003c\/li\u003e\n  \u003cli\u003eConfigurable I\/O channels through jumpers and switches on the printed circuit board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSymphony Enterprise Management and Control System networks\u003c\/li\u003e\n  \u003cli\u003eDistributed sequence of events monitoring and recording\u003c\/li\u003e\n  \u003cli\u003eHarmony Control Unit digital event collection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eProperty\u003c\/th\u003e\n      \u003cth\u003eCharacteristic \/ Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOccupies one slot in a standard module mounting unit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e+5 VDC, 15%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent (Typical)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e350 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMicroprocessor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16 bits running at 10 MHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64 kb RAM, 64 kb ROM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 16 digital field inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltages (with +\/-10% tolerance)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 VDC, 48 VDC, 125 VDC, 120 VAC (only for system control logic)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTypical Input Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5 mA (24 VDC), 4 mA (48 VDC), 4 mA (125 VDC), 5 mA (120 VAC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Turn On Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e21.6 VDC (24 VDC), 43.2 VDC (48 VDC), 112.5 VDC (125 VDC), 108 VAC (120 VAC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Turn Off Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10 VDC (24 VDC), 20 VDC (48 VDC), 50 VDC (125 VDC), 50 VAC (120 VAC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Input Current at Minimum Turn On\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 mA (21.6 VDC), 4.4 mA (43.2 VDC), 3.2 mA (112.5 VDC), 4 mA (108 VAC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Off-Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 mA (for all DI voltages)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTypical Response Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDC fast: 1.1 msec; DC slow: 18 msec; AC: 5 msec after first positive half cycle\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1,000 VDC\/VRMS channel to system; 50 VDC\/VRMS channel to channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSurge Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMeets IEEE-472-1974 surge withstand capability test\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 70 degC (32 to 158 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5% to 95% up to 55 degC (131 degF) noncondensing; 5% to 45% at 70 degC (158 degF) noncondensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eI\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAltitude\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSea level to 3 km (1.86 mi)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAir Quality\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNoncorrosive\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHardware Configuration:\u003c\/strong\u003e Before inserting the module, adjust onboard jumpers and switches to set up hardware constraints. Ensure dispshunts on the related termination unit match the configuration needs of individual I\/O channels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBus Limitations:\u003c\/strong\u003e Verify that no more than 63 digital input modules are connected along the same I\/O expander bus segment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Mounting:\u003c\/strong\u003e Place the single printed circuit board squarely inside its intended slot within the module mounting unit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Direct all physical field cabling points exclusively to the external NTDI01 termination unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark Declaration:\u003c\/strong\u003e Complies with EMC96 Directive 89\/336\/EEC (EN50082-2 Generic Immunity Standard - Part 2: Industrial Environment and EN50081-2 Generic Emission Standard - Part 2: Industrial Environment) and Low Voltage Directive 73\/23\/EEC (EN61010-1 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use) when installed in a Symphony cabinet.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCanadian Standards Association (CSA):\u003c\/strong\u003e Certified for use as process control equipment in an ordinary (nonhazardous) location.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory Mutual (FM):\u003c\/strong\u003e Pending approval for Nonincendive: Class I Division 2, Groups A, B, C, D and Class II, Division 2, Groups F, G.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668629090667,"sku":"IMSED01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-imsed01-sequence-of-events-module-tupthalzyx3_e4505278-5ffc-4984-9e23-728b8857f0c2.jpg?v=1765536095","url":"https:\/\/www.plcprotech.com\/products\/abb-imsed01-harmony-sequence-of-events-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}