{"product_id":"abb-imset01-harmony-sequence-of-events-timing-module","title":"ABB IMSET01 Harmony Sequence of Events Timing Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB IMSET01\u003c\/strong\u003e is a specialized Sequence of Events (SOE) Timing module designed for the Symphony Enterprise Management and Control System. This sequence of events timing module processes up to 16 digital field inputs while simultaneously receiving and decoding critical time synchronization link information sent from an INTKM01 Time Keeper Master module. Digital state transitions, which are transitions of a digital signal from either on to off or from off to on, are collected at the Harmony Control Unit (HCU) level by the module and then forwarded to an INSEM01 Sequence of Events Master module for precise distributed event monitoring, recording, and reporting.\u003c\/p\u003e\n\u003cp\u003eOperating over the I\/O expander bus, the \u003cstrong\u003eABB IMSET01\u003c\/strong\u003e interfaces SOE data and configures input channels via specific function codes executed by the associated Harmony controller. Each input channel is optically isolated to protect system integrity, allowing individual configuration across several operational voltage types. Only one module of this type can operate on a single I\/O expander bus segment, managing localized synchronization termination and field wiring via dedicated cable links to termination units.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Field Inputs:\u003c\/strong\u003e Processes up to 16 individual digital input channels for comprehensive state transition tracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime Synchronization Decoding:\u003c\/strong\u003e Integrates a built-in communication interface to receive and decode time synchronization link data from the master time source.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical Channel Isolation:\u003c\/strong\u003e Features high-grade optical isolation between channels and the system, as well as channel-to-channel isolation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Voltage Compatibility:\u003c\/strong\u003e Each channel can be individually configured for 24 VDC, 48 VDC, 125 VDC, or 120 VAC operational levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpander Bus Communication:\u003c\/strong\u003e Communicates directly with its designated Harmony controller over the standard I\/O expander bus segment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Withstand Capability:\u003c\/strong\u003e Built with internal protection circuits that meet the strict IEEE-472-1974 surge withstand capability standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed event monitoring and recording in Symphony control networks.\u003c\/li\u003e\n\u003cli\u003eHigh-accuracy time-stamped digital signal tracking in Harmony Control Units.\u003c\/li\u003e\n\u003cli\u003eSequence of events (SOE) logging for industrial process control logic.\u003c\/li\u003e\n\u003cli\u003ePower and sequence critical recording within process automation environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eCharacteristic \/ Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIMSET01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony Sequence of Events \/ Symphony\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSequence of Events Timing Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOccupies one slot in a standard module mounting unit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 VDC, 15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMicroprocessor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 bits running at 10 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 kb RAM, 64 kb ROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-485 time synchronization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 48 VDC, 125 VDC, 120 VAC (all +\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 mA (24 VDC), 4 mA (48 VDC), 4 mA (125 VDC), 5 mA (120 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Turn On Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.6 VDC (24V), 43.2 VDC (48V), 112.5 VDC (125V), 108 VAC (120V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Turn Off Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 VDC (24V), 20 VDC (48V), 50 VDC (125V), 50 VAC (120V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Off-Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mA (for all DI voltages)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC fast: 1.1 msec; DC slow: 18 msec; AC: 5 msec after first positive half cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 VDC\/VRMS channel to system; 50 VDC\/VRMS channel to channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeets IEEE-472-1974 surge withstand capability test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 70 degC (32 to 158 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% up to 55 degC (noncondensing); 5% to 45% at 70 degC (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAltitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSea level to 3 km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir Quality\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNoncorrosive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Placement:\u003c\/strong\u003e Insert the module assembly into its designated position in the standard module mounting unit (MMU), where it will occupy exactly one slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Configuration:\u003c\/strong\u003e Ensure all board-level jumpers and switches are set to their proper configurations to manage the module and its specific I\/O channels prior to powering the rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Cable Links:\u003c\/strong\u003e Route and connect the dedicated module cable from the unit to the corresponding NTST01 and NTD101 termination units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime Link Termination:\u003c\/strong\u003e Secure the time synchronization link termination to the NTST01 termination unit to allow appropriate decoding of the time master signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Connect all incoming external digital field wiring directly to the physical connection points provided on the NTD101 termination unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpander Bus Constraints:\u003c\/strong\u003e Verify that no other timing modules are placed on the same local network path, as only one module can operate on an I\/O expander bus segment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark Declaration:\u003c\/strong\u003e Complies with EMC96 Directive 89\/336\/EEC (EN50082-2 Generic Immunity Standard - Part 2: Industrial Environment and EN50081-2 Generic Emission Standard - Part 2: Industrial Environment) when properly installed in a Symphony cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Voltage Directive:\u003c\/strong\u003e Complies with Low Voltage Directive 73\/23\/EEC (EN61010-1 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 1: General Requirements).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA Certification:\u003c\/strong\u003e Canadian Standards Association certified for use as process control equipment in an ordinary, nonhazardous location.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668627255659,"sku":"IMSET01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-imset01-bailey-infi-90-sequence-of-event-time-keeper-module-o1pu0rudfal_9b6c116d-f873-4c3c-af9c-3ba24de82c94.jpg?v=1765536030","url":"https:\/\/www.plcprotech.com\/products\/abb-imset01-harmony-sequence-of-events-timing-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}