{"product_id":"abb-inlim03-bailey-infi-90-loop-interface-module","title":"ABB INLIM03 Bailey Infi 90 Loop Interface Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB INLIM03\u003c\/strong\u003e, a component of the \u003cstrong\u003eBailey Infi 90\u003c\/strong\u003e system, is a specialized \u003cstrong\u003eLoop Interface Module\u003c\/strong\u003e designed to manage critical data routing and transmission between individual process control equipment and the primary communication backbone. Operating in tandem with an accompanying \u003cstrong\u003eBus Interface Module (INBIM02)\u003c\/strong\u003e via a dedicated ribbon cable link, this device handles complex multi-node orchestration tasks without relying on a centralized master traffic controller. By serving as a localized gateway, the module helps isolate high-throughput automated adjustments from macro-level loop congestion.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcess Control Units (PCU) communication bridging\u003c\/li\u003e\n\u003cli\u003eHigh-speed serial data transmission within industrial Plant Loops\u003c\/li\u003e\n\u003cli\u003eRedundant network topology orchestration in process management setups\u003c\/li\u003e\n\u003cli\u003eDistributed multi-node process architecture data routing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB \/ Elsag Bailey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eINLIM03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInfi 90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kbytes RAM, 4 kbytes ROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 VDC @ 2.0 Amps (10 Watts nominal); ±15 VDC @ 80 mA (1.2 Watts nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 kbaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum System Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 63 nodes per loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Data Throughput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 messages\/second maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Synchronization Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 milliseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 70 degC (32 to 158 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Relative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 95% up to 55 degC; 0% to 45% up to 70 degC (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAtmospheric Pressure Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSea level to 3 km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Node-to-Node Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 meters (6561 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Module-to-Termination Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61 meters (200 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP1 - Pin 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 VDC Power Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP1 - Pin 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 VDC Power Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP1 - Pin 5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP1 - Pin 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP1 - Pin 7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+15 VDC Power Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP1 - Pin 8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 VDC Power Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop 2 In (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop 2 In (-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin 3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop 1 Out (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin 5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop 1 Out (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop 1 In (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin 7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop 1 In (-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin 8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin 9\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop 2 Out (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin 10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop 2 Out (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin 11\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin 13\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop 2 Bypass Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin 14\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop 1 Out (-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin E\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop 1 Out (-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop 2 Bypass Control Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin K\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop 2 Out (-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin L\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoop 2 Out (-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin M\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP3 - Pin S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eP4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRibbon Cable Connection to Bus Interface Module (BIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatic Dissipative Measures:\u003c\/strong\u003e Technicians must utilize grounded wrist straps and appropriate static dissipative work surfaces prior to handling to safeguard internal circuitry from electrostatic discharge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDipswitch Configurations:\u003c\/strong\u003e Set the S1 option dipswitch to the desired event tracking address (default position: Hex 30) and configure the S2 address dipswitch to establish a unique node designation from 1 to 63.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Interconnection:\u003c\/strong\u003e Securely connect the ribbon cable between the P4 slot of the device and the corresponding P4 slot of the partner module before inserting the joined assembly into the frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Slot Mount:\u003c\/strong\u003e Slide the unit directly along the plastic guide rails within the designated Module Mounting Unit (MMU) slot until the front faceplate rests flush with the upper and lower framing edges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFaceplate Locking:\u003c\/strong\u003e Hand-tighten the dual captive faceplate screws by rotating each a 1\/2 turn to lock the hardware firmly into position within the chassis card cage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Orientation Warning:\u003c\/strong\u003e When completing termination paths using the dedicated cabling assembly, confirm that the designated J1 cable ending attaches to the terminal card edge (P1 connector) and the J2 ending seats properly directly onto the device module. Incorrect configuration can cause immediate electrical damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA certified for use as process control equipment in ordinary, non-hazardous environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668623159659,"sku":"INLIM03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-inlim03-infi-90-loop-interface-module-nquuhaggyzb_b9183fa9-35bc-4662-8cac-8f613d4cabe6.jpg?v=1765535884","url":"https:\/\/www.plcprotech.com\/products\/abb-inlim03-bailey-infi-90-loop-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}