{"product_id":"abb-pfpa201-3bse022827r1-pfp200-cylmate-data-processing-unit","title":"ABB PFPA201 3BSE022827R1 PFP200 Cylmate Data Processing Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePFPA201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3BSE022827R1\u003c\/strong\u003e) is a high-precision Data Processing Unit (DPU) specifically engineered for the Cylmate Engine Monitoring system. As a core component of the PFP200 series (versions prior to 3.0), this module is designed for continuous, real-time monitoring of large-bore diesel and gas engines, typically used in marine propulsion and power generation. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePFPA201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Version 2.0) processes complex combustion data, cylinder pressure signals, and crank angle measurements to optimize engine performance and prevent mechanical failure. This unit acts as the primary computational hub, translating raw sensor input into actionable diagnostic data for the engine's control system and operator interfaces.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePFPA201\u003c\/strong\u003e (2.0)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3BSE022827R1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCylmate Data Processing Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePFP200 Engine Monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSoftware Requirement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOperator Station Software 2.0 or higher\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGross Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85389091\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Not in WEEE Scope\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eReplacement Part ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3BSE022827R2\u003c\/strong\u003e (Successor Model)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eIndustrial engine monitoring components must be ordered by the specific Revision\/Version number to ensure software compatibility. Note that the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePFPA201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVersion 2.0 requires corresponding software versions for full functionality.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct ID:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3BSE022827R1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eABB Type Designation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePFPA201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(2.0)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInvoice Description:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePFPA201 Cylmate Data Processing Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Order Quantity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 piece\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003ch3\u003eSoftware and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePFPA201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVersion 2.0 must be utilized in conjunction with Operator Station Software version 2.0. Utilizing this hardware with legacy 1.x software versions or mismatched firmware will result in communication errors and incorrect data processing. Before installation, verify the existing system's software architecture to ensure seamless integration.\u003c\/p\u003e\n\u003ch3\u003eMounting and Environmental Protection\u003c\/h3\u003e\n\u003cp\u003eThis unit is classified under \"Spare_Parts\" for frame size considerations but requires a stable, vibration-damped mounting environment within the engine control cabinet. Given its application in engine rooms, ensure that the cabinet provides adequate protection against oil mist and thermal stress. The unit weighs 4.5 kg; ensure mounting brackets are rated for high-vibration maritime or industrial environments.\u003c\/p\u003e\n\u003ch3\u003eSystem Lifecycle and Replacement\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3BSE022827R1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis part of the previous hierarchy of Force Measurement Portfolio (before version 3.0). For new installations or total system overhauls, the replacement Product ID\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3BSE022827R2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis available. When replacing a failed DPU, it is recommended to back up current configuration parameters from the Operator Station before disconnecting the existing hardware.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the PFPA201 in a Cylmate system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePFPA201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the central processing engine that calculates cylinder-specific data such as Pmax (peak pressure), Ptdc (pressure at top dead center), and indicated power, providing the necessary data for engine balancing and fuel optimization.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use PFPA201 (2.0) with Software Version 1.x?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Technical documentation specifies that Data Processing Unit 2.0 strictly requires Operator Station Software 2.0. Upgrading hardware without a corresponding software update will lead to system incompatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit suitable for hazardous area installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePFPA201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically installed in the engine control room or a protected engine-side cabinet. For specific ATEX or marine class certification (DNV, GL, etc.), refer to the original system-wide certification documentation provided with the PFP200 series.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668586197355,"sku":"PFPA201 3BSE022827R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-pfpa201-3bse022827r1-communication-module-tjsusvpacct_433977ca-8ede-43d8-88a5-288d48267c31.jpg?v=1765533027","url":"https:\/\/www.plcprotech.com\/products\/abb-pfpa201-3bse022827r1-pfp200-cylmate-data-processing-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}