{"product_id":"abb-pm-876-3bdh000607r1-symphony-plus-controller-module","title":"ABB PM 876 3BDH000607R1 Symphony Plus Controller Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePM 876\u003c\/strong\u003e (Product ID: \u003cstrong\u003e3BDH000607R1\u003c\/strong\u003e) is a high-capacity central processing hardware \u003cstrong\u003econtroller\u003c\/strong\u003e unit belonging to the \u003cstrong\u003eSymphony Plus\u003c\/strong\u003e distributed control system (DCS) platform. This hardware assembly orchestrates plant-wide control loops, handles process data calculation, and executes complex automation logic across continuous process fields. The \u003cstrong\u003ePM 876 3BDH000607R1\u003c\/strong\u003e is built with high-density physical on-board communication interfaces, providing 1 x Onet (Operations Network), 1 x redundant Cnet (Control Network), 1 x redundant Fnet (Field Network), 2 x PROFIBUS DP lines, and 1 x Ethernet channel. To preserve real-time user tables, calibration registers, and volatile memory states through complete main power input disruptions, the controller is shipped complete with an internal lithium metal backup battery cell. Firmware updates, including upgrades or downgrades, can be performed using a standard external USB flash drive or a dedicated system analyzer. When deployed in a redundant controller topology, the module interfaces via a separate \u003cstrong\u003eNT 031\u003c\/strong\u003e redundancy link connection cable.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentral industrial processor module for the Symphony Plus control and communication system architecture.\u003c\/li\u003e\n\u003cli\u003eIntegrated communication network arrays including Onet, redundant Cnet, redundant Fnet, and an Ethernet interface.\u003c\/li\u003e\n\u003cli\u003eDual physical built-in PROFIBUS DPV2 master interface channels for extended decentralized instrument loops.\u003c\/li\u003e\n\u003cli\u003eFlexible local software field servicing supporting quick firmware modification via an external USB-Stick.\u003c\/li\u003e\n\u003cli\u003eBuilt-in hardware support for redundant unit configuration paths using the NT 031 redundancy link cable.\u003c\/li\u003e\n\u003cli\u003eFactory package comes fully populated with a dedicated 30 g lithium metal backup battery cell.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge-scale multi-protocol network routing and processing control in power generation utilities.\u003c\/li\u003e\n\u003cli\u003eHigh-availability operations requiring hot-standby CPU redundancy and concurrent fieldbus link control.\u003c\/li\u003e\n\u003cli\u003eAutomation drop consolidation bridging enterprise Ethernet networks with dedicated deterministic plant sub-networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Ordering Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM 876\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BDH000607R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM 876, Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM 876 Controller Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eBackup Lithium Metal Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Accessories (Not Included)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRedundancy Link Cable NT 031 (Required for redundant mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP \/ IEC 61850 activation licenses (Required for protocol release)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM 876\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BDH000607R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCentral_Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOnboard Network Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x Onet, 1 x redundant Cnet, 1 x redundant Fnet, 2 x DPV2, 1 x Eth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirmware Transfer Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp- \/ downgrade of FW via USB-Stick or Analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Chemical Composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLithium Metal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePortable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85371091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Mounting:\u003c\/strong\u003e Secure the central chassis vertically inside a standard grounded control enclosure. Ensure all structural lock tabs engage completely to withstand vibration and establish an electrical grounding connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Linking:\u003c\/strong\u003e For dual-controller tracking setups, configure the adjacent twin unit and interconnect them using the required NT 031 redundancy link cable before completing the initialization sequence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow Optimization:\u003c\/strong\u003e Keep a minimum 50 mm clearance gap clear above and beneath the external heat-sink surfaces to facilitate ventilation and prevent heat build-up inside the enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Initialization:\u003c\/strong\u003e When applying firmware adjustments or updates locally via a USB-Stick, verify that the storage medium is correctly formatted and that power supply lines are fully stable throughout the installation loop.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eStandard \/ Directive\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFollowing EU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668620472683,"sku":"PM876 3BDH000607R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-pm876-3bdh000607r1-industrial-controller-q2qrgovsd3t_d3a23261-9db0-420d-bbab-8b356f91d0e1.jpg?v=1765535770","url":"https:\/\/www.plcprotech.com\/products\/abb-pm-876-3bdh000607r1-symphony-plus-controller-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}