{"product_id":"abb-pm862k02-3bse081636r1-ac-800m-redundant-processor-unit","title":"ABB PM862K02 3BSE081636R1 AC 800M Redundant Processor Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePM862K02\u003c\/strong\u003e is a specialized hardware package featuring a \u003cstrong\u003eRedundant Processor Unit\u003c\/strong\u003e designed to operate within the \u003cstrong\u003eAC 800M\u003c\/strong\u003e controller system infrastructure. This controller hardware serves as a central computing and processing unit for large-scale industrial process control loop requirements. It supports multi-channel interface structures through its direct electrical ModuleBus, enabling connection to up to 12 S800 I\/O units for processing varied digital and analog input\/output data signals. Built for industrial process automation and distributed control networks, the module provides specialized onboard serial and Ethernet interfaces to achieve reliable point-to-point and network-wide industrial communications. The hardware platform is fully compatible with \u003cstrong\u003e800xA\u003c\/strong\u003e 6.0.2 system environments as well as \u003cstrong\u003eCompact Control Builder\u003c\/strong\u003e 6.0.0-1 software versions and subsequent releases.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual processor configuration containing two PM862 central processing units alongside twin TP830 baseplates for system uptime protection.\u003c\/li\u003e\n\u003cli\u003eIntegrated electrical ModuleBus framework allowing continuous data mapping with up to 12 localized S800 I\/O blocks.\u003c\/li\u003e\n\u003cli\u003eBuilt-in communication interfaces featuring dual Ethernet ports (CN1 and CN2) for broad network integration and an independent RS-232C serial link for dedicated service tool interactions.\u003c\/li\u003e\n\u003cli\u003eSpecialized Redundancy Control Link port integrated directly on the processor layout for dedicated runtime backup data synchronizations.\u003c\/li\u003e\n\u003cli\u003eNon-volatile Compact Flash card reader interface provided to ensure quick loading of critical operational code and reliable cold retain variable storage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe processing assembly is widely deployed for core automation tasks across:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e800xA System\u003c\/strong\u003e industrial operations requiring highly reliable controller architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Control Builder\u003c\/strong\u003e applications handling sophisticated logic handling and loop distribution configurations.\u003c\/li\u003e\n\u003cli\u003eCritical infrastructure processes demanding redundant hardware tracking, automated CPU fallback procedures, and extensive field I\/O expansion setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eABB Type Designation\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCatalog Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BSE081636R1\u003c\/td\u003e\n\u003ctd\u003ePM862K02\u003c\/td\u003e\n\u003ctd\u003ePM862K02 Redundant Processor Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE081636R1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABB Type Designation\u003c\/td\u003e\n\u003ctd\u003ePM862K02 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCentral_Unit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Frequency\u003c\/td\u003e\n\u003ctd\u003e67 MHz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard Microprocessor\u003c\/td\u003e\n\u003ctd\u003eMPC866 running at 133 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e32 MB SDRAM (RAM), 4 MB Flash PROM firmware storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e5.1 W typical \/ 8.6 W typical including full supply to ModuleBus and CEX-Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e210 mA typical (360 mA max.) excluding supply of ModuleBus and CEX-Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Requirements\u003c\/td\u003e\n\u003ctd\u003e24 V nominal, variation between 19.2 V DC and 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant Power Supply Status Inputs\u003c\/td\u003e\n\u003ctd\u003eInputs designated SA, SB; Max input voltage 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Reservoir\u003c\/td\u003e\n\u003ctd\u003eInternal 5ms power reservoir for controlled power down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 according to EN60529, IEC 529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Depth \/ Length\u003c\/td\u003e\n\u003ctd\u003e135 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Height\u003c\/td\u003e\n\u003ctd\u003e186 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Width\u003c\/td\u003e\n\u003ctd\u003e119 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003e2.7 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Batteries\u003c\/td\u003e\n\u003ctd\u003e2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Chemical Composition\u003c\/td\u003e\n\u003ctd\u003eLithium \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003ePortable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Weight\u003c\/td\u003e\n\u003ctd\u003e9 g \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e85371091 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eL+ \/ L-\u003c\/td\u003e\n\u003ctd\u003ePower Input Connector Terminal (24 V DC Nominal Inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSA \/ SB\u003c\/td\u003e\n\u003ctd\u003eRedundant Power Supply Status Inputs (Max 30 V Input Limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN1 \/ CN2\u003c\/td\u003e\n\u003ctd\u003eEthernet Ports (IEEE 802.3, 10BaseT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM3\u003c\/td\u003e\n\u003ctd\u003eSerial Port (RS-232C) with Modem Support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM4\u003c\/td\u003e\n\u003ctd\u003eSerial Port (RS-232C) for Service Tool Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Assembly:\u003c\/strong\u003e Secure the dual baseplates cleanly before fitting the processor units onto the carrier frames to protect the underlying communication pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connections:\u003c\/strong\u003e Wire the power distribution lines directly to the four-pin screw connector inputs using proper insulation and monitoring designated L+, L-, SA, and SB lines accurately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Termination:\u003c\/strong\u003e Always ensure that both ModuleBus terminators provided in the package are securely fitted to the end of the functional hardware train to maintain clear loop signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Maintenance:\u003c\/strong\u003e Keep the dual portable memory backup batteries properly inserted into their designated retaining slots to guarantee long-term retain variable protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoHS Information: Following EU Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668583412075,"sku":"PM862K02 3BSE081636R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-pm862k02-3bse081636r1-ac-800m-controllers-vhtxzytpuur_c1b3c0c3-ebd7-473d-baaf-34ef5289dceb.jpg?v=1765532964","url":"https:\/\/www.plcprotech.com\/products\/abb-pm862k02-3bse081636r1-ac-800m-redundant-processor-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}