{"product_id":"abb-s282uc-k2-ghs2820164r0277-s280uc-miniature-circuit-breakers-mcbs","title":"ABB S282UC-K2 GHS2820164R0277 S280UC Miniature Circuit Breakers MCBs","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eS282UC-K2\u003c\/strong\u003e universal current miniature circuit breaker with Product ID \u003cstrong\u003eGHS2820164R0277\u003c\/strong\u003e is a 2-pole electrical device engineered to deliver comprehensive current limitation, short-circuit protection, and overcurrent mitigation. As part of the \u003cstrong\u003eS280UC\u003c\/strong\u003e product series, this unit features a delayed thermal tripping mechanism for overload protection and an electromechanic magnetic tripping mechanism for short circuit protection. It is specifically optimized with a high DC voltage rating to serve as a reliable solution for direct current sub-circuits up to 440 V DC across two poles, making it highly compatible with applications in photovoltaics, telecommunication infrastructure, electric traction setups, and specialized industrial settings.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEquipped with a 2-pole hardware architecture supporting multi-line configuration protection.\u003c\/li\u003e\n\u003cli\u003eUtilizes a K-characteristic tripping curve designed to handle specific inductive current parameters.\u003c\/li\u003e\n\u003cli\u003eFeatures a universal current architecture certified for both alternating current and high-voltage direct current distribution.\u003c\/li\u003e\n\u003cli\u003eIncorporates an insulation group I housing finished in RAL 7035 with a sealable black insulation group II actuator handle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePhotovoltaic power string arrays and solar combiner panel boxes.\u003c\/li\u003e\n\u003cli\u003eTelecommunication power backup networks and traction sub-stations.\u003c\/li\u003e\n\u003cli\u003eIndustrial direct current control circuits requiring specialized branch circuit overcurrent protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Product Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS282UC-K2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGHS2820164R0277\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4012233652808\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGHS2820164R0277\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Product Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS282UC-K2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTripping Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Ultimate Short-Circuit Breaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.0 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV (6.2 kV at sea level, 5.0 kV at 2000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Test Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz, 1 min.: 2 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation group I, RAL 7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation group II, black, sealable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI \/ O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Position Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eON \/ OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (IP40 inside an enclosure with cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Endurance (Nelec)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Endurance (Nendu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20000 cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScrew Terminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnecting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRigid 0.75 ... 25 mm² \/ Flexible with Ferrule 0.75 ... 16 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening Torques\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 N-m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Screw Driver\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePozidriv 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Voltage UL\/CSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V DC \/ 480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Installation:\u003c\/strong\u003e Secure the unit onto standard symmetrical tracks including TH35-7.5 (35 x 7.5 mm mounting rail) or TH35-15 (35 x 15 mm mounting rail) in compliance with IEC 60715.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Position:\u003c\/strong\u003e The mechanical frame allows assembly at any functional orientation angle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolarity Tracking:\u003c\/strong\u003e Ensure specific attention is paid to the verified polarity markings of the device during direct current circuit wire placement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Connections:\u003c\/strong\u003e Connect conductors tightly to the integrated cable clamp screw terminals using a Pozidriv 2 tool to ensure a torque of 2.5 N-m.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53456031187307,"sku":"S282UC-K GHS2820164R0277","price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/S282UC-K2_GHS2820164R0277.jpg?v=1783126448","url":"https:\/\/www.plcprotech.com\/products\/abb-s282uc-k2-ghs2820164r0277-s280uc-miniature-circuit-breakers-mcbs","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}