{"product_id":"abb-spiit13-symphony-plus-infi-net-to-infi-net-local-transfer-module","title":"ABB SPIIT13 Symphony Plus INFI-NET to INFI-NET Local Transfer Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThe ABB SPIIT13 is a high-performance communication module built for the Symphony Plus and Harmony Rack automation series to execute direct communication routing between discrete rings or networks. Functioning as an INFI-NET to INFI-NET Local Transfer Module, this unit establishes a deterministic data bridge that transfers time-critical process values, control commands, and system diagnostics locally between separate system rings without routing latency. Equipped with an onboard lithium button cell battery to maintain volatile configuration memory during master power cycling, this module provides the dependable backplane-to-network data bridging required to keep large-scale distributed control systems fully synchronized and operational.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocal Ring Bridging:\u003c\/strong\u003e Enables native high-throughput data transfer between distinct INFI-NET communication segments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Symphony Plus Compatibility:\u003c\/strong\u003e Form-factor optimized for direct slot insertion inside standard Harmony Rack (S+ HR) enclosures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOnboard Battery Backup:\u003c\/strong\u003e Features an integrated 5-gram lithium button cell battery to preserve volatile configuration records during power isolation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHardware Determinism:\u003c\/strong\u003e Provides secure data processing parameters to prevent packet loss across continuous control networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli\u003eInterfacing adjacent network communication zones in subcritical power plant control architectures.\u003c\/li\u003e\n  \u003cli\u003eManaging distributed controller data exchanges within municipal water treatment facilities and petrochemical plants.\u003c\/li\u003e\n  \u003cli\u003eExpanding Harmony Rack network topologies by safely linking distinct data rings localized to the same hardware suite.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSystem Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSymphony Plus \/ Harmony Rack (S+ HR)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSPIIT13\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct ID\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSPIIT13\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCommunication Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCustoms Tariff Number \/ HS Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e85176200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eBattery Profile\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1 x Lithium Button Cell (5 g)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Net Depth \/ Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e73.66 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Net Height\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e358.14 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Net Width\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e271.78 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Net Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.95 kg (Estimated, OEM specifies base 0.00 kg skeleton weight)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1.45 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e410 x 320 x 110 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eUnited States (US)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 12px; margin-bottom: 15px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 4px 0 0 0;\"\u003eIsolate the rack housing assembly from all live power paths before attempting insertion or extraction of the communication card. Live insertion risks causing instantaneous backplane bus disruptions, data frame loss across the broader INFI-NET loop, and structural hardware degradation due to transient electrical spikes.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 10px;\"\u003e\n  \u003cdiv style=\"display: inline-block; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; text-align: center; font-weight: bold; margin-right: 8px;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"display: inline-block; color: #2d3748;\"\u003eAttach an anti-static grounding strap securely to your forearm, ensuring the grounding clip is bonded directly to an unpainted metal surface on the instrument cabinet frame.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 10px;\"\u003e\n  \u003cdiv style=\"display: inline-block; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; text-align: center; font-weight: bold; margin-right: 8px;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"display: inline-block; color: #2d3748;\"\u003eInspect the battery compartment to ensure the 5g lithium button cell is installed securely and positioned with correct polarity prior to inserting the card into the rack guides.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 10px;\"\u003e\n  \u003cdiv style=\"display: inline-block; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; text-align: center; font-weight: bold; margin-right: 8px;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"display: inline-block; color: #2d3748;\"\u003eAlign the edges of the module with the card tracks inside the Harmony Rack chassis slot, pushing the unit inward using balanced, steady pressure until the rear connection array mates fully with the backplane.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 10px;\"\u003e\n  \u003cdiv style=\"display: inline-block; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; text-align: center; font-weight: bold; margin-right: 8px;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"display: inline-block; color: #2d3748;\"\u003eFasten the top and bottom mechanical faceplate screws to guarantee proper ground continuation, hook up the local network coaxial or twinaxial lines, and restore system power to initialize runtime configurations.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668628664683,"sku":"SPIIT13","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-spiit13-local-control-module-s5zlgizzp0t_53d49664-feff-4c3a-9974-87cf0ad36d9a.jpg?v=1765536079","url":"https:\/\/www.plcprotech.com\/products\/abb-spiit13-symphony-plus-infi-net-to-infi-net-local-transfer-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}