{"product_id":"abb-sprio22-harmony-remote-rack-i-o-module","title":"ABB SPRIO22 Harmony Remote Rack I\/O Module","description":"\u003cp style=\"color: #2d3748; font-family: sans-serif;\"\u003eThe \u003cstrong\u003eABB SPRIO22\u003c\/strong\u003e is a high-integrity communication interface module designed for the Symphony Plus distributed control system architecture to coordinate distributed subrack grouping. Operating within the \u003cstrong\u003eHR Series (Harmony Rack)\u003c\/strong\u003e hardware ecosystem, this module manages deterministic data aggregation and multi-node polling between centralized processing units and distant field termination assemblies over dedicated remote networks. By providing a rugged localized bridge on the \u003cstrong\u003eI\/O expander bus\u003c\/strong\u003e, it ensures high-speed, synchronized data transfer across complex power generation and continuous process plants without signal attenuation or loop latency.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; font-family: sans-serif; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"color: #2d3748; font-family: sans-serif; list-style-type: square; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRemote Rack Synchronization:\u003c\/strong\u003e Establishes long-distance communication links to tie localized instrument clusters directly into the master controller backplane.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eExpander Bus Traffic Management:\u003c\/strong\u003e Orchestrates bidirectional signal transactions across the local bus segment to prevent communication data collisions.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIntegrated Power Backup:\u003c\/strong\u003e Equipped with an internal lithium button cell battery to safeguard persistent configuration memory and network node settings during sudden plant blackouts.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRugged Hardware Form Factor:\u003c\/strong\u003e Built in a standard 19-inch rack-ready design to withstand heavy electromagnetic fields and thermal stress on the plant floor.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eFault-Tolerant Isolation:\u003c\/strong\u003e Protects upstream backplane processing lines from field-side electrical surges and dynamic ground potential differences.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; font-family: sans-serif; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"color: #2d3748; font-family: sans-serif; list-style-type: square; padding-left: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eWide-area remote input and output expansion enclosures in thermal power stations.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eDistributed utility control networks including long-distance water pipelines and pumping stations.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eOffshore drilling platforms and petrochemical processing fields requiring decentralized hardware layouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; font-family: sans-serif; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left; font-family: sans-serif; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eValue \/ Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct ID\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSPRIO22\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eABB Type Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSPRIO22\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSystem Architecture\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSymphony Plus \/ Harmony Rack System\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eI\/O Module (Remote Rack Interface)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eBattery Chemistry\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eLithium Button Cell (5 g weight, 1 included)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eBus Interface Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eI\/O expander bus\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eHS Code \/ Customs Tariff\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e85371090\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWEEE Category\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSmall Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct Net Dimensions\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e279.4 mm (W) x 355.6 mm (H) x 76.2 mm (D)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.40 kg \/ 3.1 lbs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e410 mm x 330 mm x 120 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; font-family: sans-serif; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #cc5555; padding: 15px; margin-bottom: 20px; font-family: sans-serif;\"\u003e\n  \u003cp style=\"color: #cc5555; margin: 0; font-weight: bold;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #2d3748; margin: 5px 0 0 0;\"\u003eIsolate all upstream cabinet power feeds and lock out breaker lines before attempting to insert or remove this communication module. Handling remote bus connection interfaces under active power can spark localized electrical arcs, corrupting active system memory, causing loss of remote node parameters, and inducing dangerous control communication network drops.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"font-family: sans-serif; color: #2d3748;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 15px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px;\"\u003e1\u003c\/div\u003e\n    \u003cdiv\u003eAttach a verified static-safe anti-static wrist strap to a dedicated chassis metal grounding anchor before sliding the unit from its original anti-static packaging.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 15px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px;\"\u003e2\u003c\/div\u003e\n    \u003cdiv\u003eInspect the internal backup button cell battery holder to ensure full contact and check that the rear backplane pin connections are straight and free from dirt.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 15px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px;\"\u003e3\u003c\/div\u003e\n    \u003cdiv\u003eAlign the module edge rails precisely within the rack tracks, push firmly until the backplane connectors seat completely, and secure the front panel thumbscrews to ground the frame shield.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668614508907,"sku":"SPRIO22","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-sprio22-harmony-remote-rack-i-o-module-xf3fcp4dsuz_c10c368e-53cf-4eb5-9984-c1a230a99f73.jpg?v=1765535617","url":"https:\/\/www.plcprotech.com\/products\/abb-sprio22-harmony-remote-rack-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}