{"product_id":"abb-tb820v2-3bse013208r1-s800-i-o-modulebus-cluster-modem","title":"ABB TB820V2 3BSE013208R1 S800 I\/O Modulebus Cluster Modem","description":"\u003cp\u003eThe \u003cstrong\u003eTB820V2\u003c\/strong\u003e with part number \u003cstrong\u003e3BSE013208R1\u003c\/strong\u003e is an optical cluster modem designed for non-redundant communication operations within the \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e system framework. It functions as a specialized interface for the reception, conversion, transmission, and regeneration of data signals across local or wide area industrial networks. The module establishes secure, fiber-optic links between distributed \u003cstrong\u003eS800 I\/O\u003c\/strong\u003e clusters and central controllers, ensuring noise-immune data transfer in harsh environments. Each unit comes packaged with a dedicated power supply connector and a \u003cstrong\u003eTB807 Modulebus Terminator\u003c\/strong\u003e to ensure correct electrical termination of the local bus cluster.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTB820V2\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e3BSE013208R1: Modulebus Cluster Modem (Non-redundant operation)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTB820V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE013208R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModulebus Cluster Modem\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O, System 800xA (Versions 4.0, 4.1, 5.0, 5.1, 6.0), Advant OCS with Master SW, Advant OCS with MOD 300 SW, Compact Product Suite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x Power Supply Connector, 1 x TB807 Modulebus Terminator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Batteries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFollowing EU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Architecture Integration\u003c\/strong\u003e: The cluster modem operates within the local Modulebus hierarchy to bridge communication between external controller racks and distributed S800 remote I\/O blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Requirement\u003c\/strong\u003e: Correct bus topology requires the installation of the included TB807 Modulebus Terminator at the physical end of the localized cluster segment to suppress signal reflections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Redundant Configuration\u003c\/strong\u003e: This hardware variant is optimized strictly for simplex (non-redundant) communication lines; dual-line pathing architectures require alternative module selections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Platform Compatibility\u003c\/strong\u003e: Fully verified for cross-generational deployment, bridging legacy Advant Fieldbus 100 systems with modern System 800xA control configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Assembly\u003c\/strong\u003e: Mount the unit onto its designated backplane slot within the I\/O chassis, securing any mechanical lock latches to ensure solid alignment with the backplane communication rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection\u003c\/strong\u003e: Use only the provided power supply connector block to land the required operational voltages, ensuring correct polarity before energizing the circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Optic Handling\u003c\/strong\u003e: Avoid sharp bends or pulling stresses on the optical patch cables connected to the modem interface, as excessive attenuation or physical breakage can degrade cyclic data exchange.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge Precautions\u003c\/strong\u003e: Adhere to strict industrial ESD measures, including wearing an approved grounding wrist strap, when handling the modem or installing the terminating plug.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What physical accessories are included standard in the box with this model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Every unit ships complete with one power supply connector and one TB807 Modulebus Terminator block.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this specific module designation be deployed in a redundant network communication layout?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, this unit is engineered and specified strictly for non-redundant network configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this hardware module require any internal backup batteries for configuration retention?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the module operates with zero internal batteries, running completely on external system backplane power.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668514435435,"sku":"3BSE013208R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tb820v2-3bse013208r1-modulebus-optical-modem-t5d5kfhvioi_0d061849-df46-4de7-9bd4-4c6603e63913.jpg?v=1765532624","url":"https:\/\/www.plcprotech.com\/products\/abb-tb820v2-3bse013208r1-s800-i-o-modulebus-cluster-modem","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}