{"product_id":"abb-tc513v1-3bse018405r1-af100-twisted-pair-coax-modem","title":"ABB TC513V1 3BSE018405R1 AF100 Twisted Pair Coax Modem","description":"\u003cp style=\"color: #2d3748;\"\u003eThe \u003cstrong\u003eABB 3BSE018405R1 TC513V1\u003c\/strong\u003e is a high-reliability Advant Fieldbus 100 (AF100) media converter designed for seamless data transmission between \u003cstrong\u003etwisted pair and coaxial cables\u003c\/strong\u003e in industrial process control environments. This communication module ensures secure, real-time signal conversion across critical network topologies, supporting bidirectional \u003cstrong\u003ecoax-to-twisted pair\u003c\/strong\u003e or \u003cstrong\u003etwisted pair-to-coax\u003c\/strong\u003e routing configurations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Media Conversion:\u003c\/strong\u003e Provides reliable interfacing for Advant Fieldbus 100 twisted pair\/coax or coax\/twisted pair network segments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Features a rated isolation voltage of 50V to protect sensitive control hardware from ground loops and electrical noise.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Power Design:\u003c\/strong\u003e Engineered to operate efficiently on a standard 24V d.c. industrial power supply.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Form Factor:\u003c\/strong\u003e Classified as small equipment with no external dimension exceeding 50 cm, optimizing cabinet space.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS Exemption Compliance:\u003c\/strong\u003e Documented as exempted from the scope of 2011\/65\/EU (RoHS) under Article 2(4)(c), (e), (f), and (j) provisions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eABB System 800xA Integrations:\u003c\/strong\u003e Acts as a critical communication node within S800 I\/O 4.0, 4.1, 5.0, and 5.1 systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvant OCS with Master SW:\u003c\/strong\u003e Fully compatible with Advant Controller 160 (Version 2.2), Advant Controller 410 (Version 1.5), Advant Controller 450 (Version 2.3), and Advant Controller 450RMC.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvant OCS with MOD 300 SW:\u003c\/strong\u003e Deployed in specialized communication networks utilizing AC410 and AC460 controllers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEngineering Workstations:\u003c\/strong\u003e Interfaces directly with Advant Station 100 Engineering Boards via PCI communication modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eValue \/ Detail\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct ID\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3BSE018405R1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eABB Type Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTC513V1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCommunication Module \/ Media Converter\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNetwork Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eAdvant Fieldbus 100 (AF100)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRated Operational Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24V d.c.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eRated Isolation Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e50V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eWEEE Category\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eProduct Category 5 - Small Equipment (No External Dimension More Than 50 cm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNumber of Batteries\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eHS Code \/ Customs Tariff Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e85176200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct Net Width\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e30 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct Net Height\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e150 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct Net Depth \/ Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e200 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct Net Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.725 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSweden\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.950 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e250 mm x 180 mm x 50 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 5px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize all power distribution sources prior to starting installation or servicing. Working on active systems poses severe risks of electrical shock, device destruction, or unpredicted control network disruption. Verify that the 24V d.c. power line matches rated voltage specifications before completing connections.\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the modem securely inside a clean, grounded industrial enclosure, ensuring correct physical vertical orientation to allow efficient heat convection.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the dedicated functional ground system to the designated terminal block to guarantee 50V galvanic isolation integrity and suppress EMI\/RFI interference.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAttach the standard 24V d.c. power supply cables, keeping polarity strictly correct to prevent internal fuse degradation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eTerminate the Advant Fieldbus 100 media lines by attaching the coaxial BNC connector and wiring the twisted pair segment. Confirm that proper bus termination resistors are enabled at the physical boundaries of the network loop.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668513485163,"sku":"TC513V1 3BSE018405R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tc513v1-3bse018405r1-af100-twisted-pair-coax-modem-nt0i04ojg2e_c37d00db-5a4e-43d1-87fa-814aaed67e6b.jpg?v=1765532590","url":"https:\/\/www.plcprotech.com\/products\/abb-tc513v1-3bse018405r1-af100-twisted-pair-coax-modem","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}