{"product_id":"abb-tc625-3bse002224r1-advant-master-af100-coaxial-modem","title":"ABB TC625 3BSE002224R1 Advant Master AF100 Coaxial Modem","description":"\u003cp style=\"color: #2d3748; margin-top: 0; margin-bottom: 24px; text-align: justify;\"\u003e\n  The ABB TC625 is a hardware infrastructure interface module designed for the \u003cstrong\u003eAdvant Master Process Control System\u003c\/strong\u003e to manage deterministic data transportation across coaxial physical segments. This specialized communication link executes media translation protocols, working under product ID \u003cstrong\u003e3BSE002224R1\u003c\/strong\u003e and Type Designation \u003cstrong\u003eTC625\u003c\/strong\u003e, to bridge processing networks over \u003cstrong\u003eAdvant Fieldbus 100 (AF100)\u003c\/strong\u003e configurations. Engineered without internal cooling fans, this device drives electrical signals along high-integrity coaxial networks to sustain zero-packet-loss routing within centralized plant grids. The unit is optimized for multi-node automation topologies, protecting time-critical application loops from physical signal degradation while supporting full compatibility with core communication backplanes and dedicated transceiver sets.\n\u003c\/p\u003e\n\n\u003cdiv style=\"border-top: 3px solid #1a365d; padding: 20px; border-radius: 4px; box-shadow: 0 1px 3px rgba(0,0,0,0.05); margin-bottom: 20px; box-sizing: border-box;\"\u003e\n  \u003ch3 style=\"color: #1a365d; margin-top: 0; margin-bottom: 12px; font-weight: bold; text-transform: uppercase; letter-spacing: 0.5px;\"\u003eKey Features\u003c\/h3\u003e\n  \u003cul style=\"margin: 0; padding-left: 15px; list-style-type: square; color: #2d3748;\"\u003e\n    \u003cli style=\"margin-bottom: 8px;\"\u003eDirect translation architecture optimizing raw signal conversion on active AF100 industrial fieldbuses.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 8px;\"\u003eExempted from 2011\/65\/EU RoHS scope per specialized heavy industry system provisions.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 8px;\"\u003eExchange component configuration matching exact factory cross-references under code EXC3BSE002224R1.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 0;\"\u003eRugged modular casing built to slot securely into dedicated industrial sub-rack tracks.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"border-top: 3px solid #2b6cb0; padding: 20px; border-radius: 4px; box-shadow: 0 1px 3px rgba(0,0,0,0.05); margin-bottom: 25px; box-sizing: border-box;\"\u003e\n  \u003ch3 style=\"color: #2b6cb0; margin-top: 0; margin-bottom: 12px; font-weight: bold; text-transform: uppercase; letter-spacing: 0.5px;\"\u003eTarget Deployment\u003c\/h3\u003e\n  \u003cul style=\"margin: 0; padding-left: 15px; list-style-type: square; color: #2d3748;\"\u003e\n    \u003cli style=\"margin-bottom: 8px;\"\u003eAdvant Controller 450 Version 2.3 logic sub-racks running complex process control topologies.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 8px;\"\u003eAdvant Controller 410 Version 1.5 installations requiring expanded remote node networking.\u003c\/li\u003e\n    \u003cli style=\"margin-bottom: 0;\"\u003eSystem 800xA control infrastructure utilizing active Advant Fieldbus 100 interface blocks.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 6px; margin-top: 30px; margin-bottom: 15px; font-weight: bold;\"\u003eSystem Compatibility Kit\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 15px;\"\u003e\n  This un-bundled modem component integrates natively into standard corporate system kits and designated transceiver layouts:\n\u003c\/p\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch; margin-bottom: 30px; border: 1px solid #e2e8f0; border-radius: 4px; box-sizing: border-box; padding: 0;\"\u003e\n  \u003ctable style=\"width: 100%; min-width: 600px; border-collapse: collapse; text-align: left; table-layout: auto;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 12px 15px; font-weight: bold; text-transform: uppercase; letter-spacing: 0.5px; color: #1a365d;\"\u003eKit Identifier\u003c\/th\u003e\n        \u003cth style=\"padding: 12px 15px; font-weight: bold; text-transform: uppercase; letter-spacing: 0.5px; color: #1a365d;\"\u003eKit Component Nomenclature\u003c\/th\u003e\n        \u003cth style=\"padding: 12px 15px; font-weight: bold; text-transform: uppercase; letter-spacing: 0.5px; color: #1a365d; text-align: center; width: 10%;\"\u003eQty\u003c\/th\u003e\n        \u003cth style=\"padding: 12px 15px; font-weight: bold; text-transform: uppercase; letter-spacing: 0.5px; color: #1a365d; width: 15%;\"\u003eUnit\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 15px; font-family: monospace; font-weight: bold; color: #2b6cb0;\"\u003e3BSE014070R1\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; color: #2d3748;\"\u003eAF 100 Communication set\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; text-align: center; color: #2d3748;\"\u003e1\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; color: #718096;\"\u003epiece\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 15px; font-family: monospace; font-weight: bold; color: #2b6cb0;\"\u003e3BSE018448R1\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; color: #2d3748;\"\u003eCI522AK01 AF 100 Comm. Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; text-align: center; color: #2d3748;\"\u003e1\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; color: #718096;\"\u003epiece\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 15px; font-family: monospace; font-weight: bold; color: #2b6cb0;\"\u003e3BSE018449R1\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; color: #2d3748;\"\u003eCI522AK02 AF 100 Interface for Bus\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; text-align: center; color: #2d3748;\"\u003e1\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; color: #718096;\"\u003epiece\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 15px; font-family: monospace; font-weight: bold; color: #2b6cb0;\"\u003e3BSE018450R1\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; color: #2d3748;\"\u003eCI522AK03 AF 100 Interface for Bus\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; text-align: center; color: #2d3748;\"\u003e1\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; color: #718096;\"\u003epiece\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 6px; margin-top: 30px; margin-bottom: 15px; font-weight: bold;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch; margin-bottom: 30px; border: 1px solid #e2e8f0; border-radius: 4px; box-sizing: border-box; padding: 0;\"\u003e\n  \u003ctable style=\"width: 100%; min-width: 600px; border-collapse: collapse; text-align: left; table-layout: auto;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"padding: 12px 15px; font-weight: bold; text-transform: uppercase; letter-spacing: 0.5px; color: #2d3748; width: 40%;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 12px 15px; font-weight: bold; text-transform: uppercase; letter-spacing: 0.5px; color: #2d3748; width: 60%;\"\u003eCertified Engineering Data\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 15px; font-weight: bold; color: #4a5568;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; color: #2d3748;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 15px; font-weight: bold; color: #4a5568;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; color: #2d3748;\"\u003eCommunication_Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 15px; font-weight: bold; color: #4a5568;\"\u003eSub-Category\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; color: #2d3748;\"\u003eTC625 Advant Fieldbus 100 Coaxial Modem\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 15px; font-weight: bold; color: #4a5568;\"\u003eAlternative Cross-Reference ID\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; font-family: monospace; color: #2d3748;\"\u003eEXC3BSE002224R1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 15px; font-weight: bold; color: #4a5568;\"\u003eCustoms Tariff Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; font-family: monospace; color: #2d3748;\"\u003e85176200\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 15px; font-weight: bold; color: #4a5568;\"\u003eHS Code Description\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; color: #2d3748;\"\u003eMachines for the reception, conversion and transmission or regeneration of voice, images or other data\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 15px; font-weight: bold; color: #4a5568;\"\u003eProduct Net Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; color: #2d3748;\"\u003e0.29 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 15px; font-weight: bold; color: #4a5568;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; color: #2d3748;\"\u003eSweden\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 15px; font-weight: bold; color: #4a5568;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; color: #2d3748;\"\u003e0.48 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 12px 15px; font-weight: bold; color: #4a5568;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px 15px; color: #2d3748;\"\u003e245 mm x 160 mm x 60 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #e2e8f0; padding-bottom: 6px; margin-top: 30px; margin-bottom: 15px; font-weight: bold;\"\u003eField Installation Protocol\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 20px;\"\u003e\n  Follow precise sequence parameters to mount or swap out infrastructure interfaces safely on system sub-racks.\n\u003c\/p\u003e\n\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #e53e3e; padding: 15px; margin-bottom: 25px; border-radius: 4px; box-sizing: border-box;\"\u003e\n  \u003cdiv style=\"color: #c53030; font-weight: bold; margin-bottom: 6px; text-transform: uppercase;\"\u003e\n    Critical Warning: Network Segregation \u0026amp; Zero-Energy State\n  \u003c\/div\u003e\n  \u003cdiv style=\"color: #742a2a; text-align: justify;\"\u003e\n    Isolate auxiliary and main power feeds from the target Advant Controller rack prior to module insertion or removal. Handling coax field modems under active current risks dangerous transient signal reflection, hardware register lockup, or unexpected breakdown of adjacent communication loops.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 20px; box-sizing: border-box;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 15px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; text-align: center; font-weight: bold; line-height: 28px; box-shadow: 0 1px 3px rgba(43,108,176,0.3);\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; flex: 1;\"\u003e\n      \u003cstrong style=\"color: #1a365d; display: block; margin-bottom: 4px;\"\u003eSub-Rack Power Isolation \u0026amp; ESD Grounding\u003c\/strong\u003e\n      Completely isolate the sub-rack power supply module (such as the SA16x setup). Wear a grounded ESD wrist strap connected to the cabinet frame before unpacking the replacement unit to protect the sensitive hardware registers from static discharge.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 15px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; text-align: center; font-weight: bold; line-height: 28px; box-shadow: 0 1px 3px rgba(43,108,176,0.3);\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; flex: 1;\"\u003e\n      \u003cstrong style=\"color: #1a365d; display: block; margin-bottom: 4px;\"\u003eHardware Address \u0026amp; Jumpers Verification\u003c\/strong\u003e\n      Before inserting the card, inspect the onboard hardwired jumper links (e.g., S1\/S2 positions) against the original plant loop layout documentation. Ensure the hardware identification settings precisely match your existing Advant Controller node scheme.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 15px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; text-align: center; font-weight: bold; line-height: 28px; box-shadow: 0 1px 3px rgba(43,108,176,0.3);\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; flex: 1;\"\u003e\n      \u003cstrong style=\"color: #1a365d; display: block; margin-bottom: 4px;\"\u003eModule Alignment, Seating \u0026amp; Mechanical Earthing\u003c\/strong\u003e\n      Align the TC625 PCB edges accurately within the upper and lower plastic channel tracks of the sub-rack. Smoothly push the module back until its DIN connector fully mates with the system backplane. Securely torque the top and bottom captive screws to establish proper mechanical chassis earthing.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 15px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; text-align: center; font-weight: bold; line-height: 28px; box-shadow: 0 1px 3px rgba(43,108,176,0.3);\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; flex: 1;\"\u003e\n      \u003cstrong style=\"color: #1a365d; display: block; margin-bottom: 4px;\"\u003eCoaxial Bus Termination \u0026amp; BNC Locking\u003c\/strong\u003e\n      Connect the heavy industrial RG-6 or RG-11 coaxial physical drop segments using the dedicated BNC T-connectors. Twist the locking sleeves until fully clicked into place to shield against industrial EMI. If this modem serves as the physical endpoint of the AF100 bus topology, verify that a certified 75Ω coaxial termination resistor is securely installed on the vacant side of the BNC tee.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668496511339,"sku":"3BSE002224R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-tc625-3bse002224r1-af100-coaxial-modem-4rribwl5gcy_032231e1-942e-4f2a-a37f-7b9e0a9ae375.jpg?v=1765532364","url":"https:\/\/www.plcprotech.com\/products\/abb-tc625-3bse002224r1-advant-master-af100-coaxial-modem","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}