{"product_id":"abb-tu810v1-3bse013230r1-s800-i-o-compact-module-termination-unit","title":"ABB TU810V1 3BSE013230R1 S800 I\/O Compact Module Termination Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Serving as a robust connection interface within the S800 I\/O distributed automation architecture, the \u003cstrong\u003eABB TU810V1\u003c\/strong\u003e (part number \u003cstrong\u003e3BSE013230R1\u003c\/strong\u003e) acts as a compact module termination unit designed to route signals reliably between field wiring and active I\/O process modules. This unit accommodates up to 16 independent channels, operating at a maximum rating of 50V, making it a critical component for high-density cabinet layouts where footprint optimization is vital.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eHigh-Density Compact Footprint:\u003c\/strong\u003e Allows direct horizontal or vertical DIN-rail mounting to minimize cabinet space requirements.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003e16-Channel Configuration:\u003c\/strong\u003e Routes up to 16 individual I\/O channels alongside dual process voltage connections.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eMechanical Coding Keys:\u003c\/strong\u003e Prevents mismatched module insertion, safeguarding the active electronics from field configuration errors.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eIntegrated Modulebus Link:\u003c\/strong\u003e Seamlessly transfers signals and power to adjacent units without external jumper cables.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eDual Voltage Distribution:\u003c\/strong\u003e Includes 2 isolated groups with commoned terminal distribution points.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eAdvant OCS and System 800xA distributed control architectures.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003ePetrochemical, power generation, and water treatment field-instrumentation processing.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHigh-density electrical marshaling cabinets and field junction boxes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTU810V1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct ID \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3BSE013230R1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eS800 I\/O\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eType\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCompact Module Termination Unit (MTU)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNumber of Channels\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e16 channels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRated Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e50 V DC \/ AC maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRated Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3 A per channel maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConnection System\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSingle-wire screw clamp terminals\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConductor Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.2 to 2.5 mm² (24 to 14 AWG)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModulebus Load\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNegligible (passive routing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e165 mm x 45 mm x 72 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.20 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e85389091\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eTerminal \/ Connector Point\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTerminals 1 to 16\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eI\/O Channel connections (Signals 1 to 16)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTerminals 17 \u0026amp; 18\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eProcess Voltage Common 1 (distribution bus)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTerminals 19 \u0026amp; 20\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eProcess Voltage Common 2 (distribution bus)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The TU810V1 serves as a direct, drop-in evolution of the legacy TU810 compact MTU. The V1 variant features improved thermal tolerance and mechanical housing updates, ensuring absolute backward-compatibility with all existing S800 I\/O modules that require a 50V connection interface. If upgrading from non-V1 units, no software modifications or engineering changes are required in the System 800xA or Control Builder environments.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  While rated for 50V operational limits, designers must verify that the total accumulated current across all 16 connected channels does not exceed the capacity of the power distribution source. In highly compact enclosures, field wiring must be routed systematically to prevent localized heating near the screw terminals, which could accelerate degradation of the adjacent active I\/O modules.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  To ensure noise immunity in electromagnetic interference (EMI) heavy environments, signal cables should be shielded up to the cabinet entrance, and shields must be grounded to a designated bar separate from the MTU. Ensure that the plastic coding keys on the MTU base are properly configured to match the corresponding module type before power-up to prevent physical component damage during hot-swapping procedures.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Complete physical isolation and de-energization of the field supply and Modulebus backplane are mandatory before mounting, unmounting, or wiring the MTU. Failure to isolate power may cause electrical arcing, module destruction, or hazardous field conditions.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; color: #2d3748;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 2px;\"\u003eMount the TU810V1 MTU onto a grounded 35mm horizontal DIN rail by latching the top groove and snapping the lower locking tab onto the rail.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 2px;\"\u003eSlide the unit laterally along the DIN rail to connect its Modulebus port directly to the adjacent MTU\/Modulebus optical port, ensuring the connection latches completely.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 2px;\"\u003eStrip field signal and distribution wires to 6mm, insert them into the screw terminals (terminals 1-20), and torque them uniformly to 0.5 Nm.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"margin: 0; padding-top: 2px;\"\u003eConfigure the physical mechanical coding keys on the MTU surface to correspond with the targeted I\/O module type before docking the electronic module.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701956800875,"sku":"3BSE013230R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3bse013230r1-fbjpzifxlxq_b99e9acb-757e-4b4d-85f5-6d8fe75ecb86.jpg?v=1766478102","url":"https:\/\/www.plcprotech.com\/products\/abb-tu810v1-3bse013230r1-s800-i-o-compact-module-termination-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}