{"product_id":"abb-tzidc-v18345-2010460001-electro-pneumatic-positioner","title":"ABB TZIDC V18345-2010460001 Electro-Pneumatic Positioner","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB V18345-2010460001 (V183452010460001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a highly intelligent, electronically configurable positioner from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTZIDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. Designed for mounting on pneumatic linear or rotary actuators, this device represents the benchmark for precision in chemical, oil and gas, and power generation industries. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eV18345-2010460001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estands out due to its small footprint, robust design, and advanced air management system that minimizes air consumption while maximizing control speed. Its \"intelligence\" allows for automatic adjustment to the actuator's specific stroke and dynamics through a simple \"Autostroke\" procedure, ensuring the control valve operates with optimal stability and minimal wear.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eV18345-2010460001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a modular hardware platform to provide industry-standard 4-20 mA control with HART communication.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e: Features integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART 5\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART 7\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(depending on firmware) for remote configuration, status monitoring, and diagnostic data retrieval via handheld devices or DCS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety and Protection\u003c\/strong\u003e: This specific variant is often used in hazardous areas, typically certified for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIntrinsically Safe (Ex ia)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eapplications, allowing for safe operation in explosive atmospheres.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePneumatic Performance\u003c\/strong\u003e: Equipped with a high-capacity pneumatic relay that provides rapid response times even for large actuators, featuring a fail-safe \"Fail-Safe\" position upon loss of power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLocal UI\u003c\/strong\u003e: Features a built-in liquid crystal display (LCD) and push-buttons for onsite parameterization and status checks without the need for external tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Feedback\u003c\/strong\u003e: Utilizes a non-contact, wear-free position sensor or a high-durability mechanical linkage system to ensure long-term accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eV18345-2010460001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eTZIDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA (Two-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eHART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003ctd\u003eSingle or Double Acting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eIntrinsically Safe (Standard Configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Supply Pressure\u003c\/td\u003e\n\u003ctd\u003e1.4 to 6 bar (20 to 90 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.03 kg\/h (Instrument air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.70 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I perform an \"Autostroke\" on the V18345-2010460001?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNavigate to the local menu using the push-buttons, select \"Standard Autoadjust,\" and initiate. The positioner will automatically move the valve to its mechanical stops to calibrate the range and internal PID parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this positioner be used on a rotary actuator?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The TZIDC series is universal. While the internal electronics are the same, you must use the appropriate mounting kit (e.g., Namur\/VDI\/VDE 3845) to link the positioner to the rotary shaft.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I check if the device shows a \"Pneumatic Leak\" alarm?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the integrity of the air supply lines and the gaskets on the pneumatic manifold. Also, verify that the instrument air quality meets ISO 8573-1 (Class 2 or 3) to prevent moisture or oil from clogging the internal I\/P converter.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAir Quality Standards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe V18345-2010460001 requires high-purity instrument air. The presence of oil or water in the air supply can lead to the \"sticking\" of the internal flapper-nozzle system, causing control drift. Always install a filter-regulator with a 5-micron element immediately upstream of the device.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn high-vibration environments, ensure the mounting bracket is rigid. Excessive vibration can cause mechanical wear on the feedback linkage or induce noise into the electronic control loop. If vibration is unavoidable, consider using the \"Remote Sensor\" version of the TZIDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways use shielded twisted-pair cables for the 4-20 mA signal. The shield should be grounded only at the control system end to prevent ground loops, which can interfere with the HART communication data packets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668522660203,"sku":"V18345-2010460001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-v18345-2010460001-tzidc-electro-pneumatic-positioner-jyws1zgcknh_d4d2ae01-e2e8-45df-bb1e-13073a7f592a.jpg?v=1765532744","url":"https:\/\/www.plcprotech.com\/products\/abb-tzidc-v18345-2010460001-electro-pneumatic-positioner","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}