{"product_id":"abb-ud-c920-be101-3bhe034863r0001-ase2b-drive-control-module","title":"ABB UD C920 BE101 3BHE034863R0001 ASE2B Drive Control Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3BHE034863R0001 \u003c\/strong\u003e\u003cstrong\u003eUD C920 BE101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eUDC920BE101\u003c\/strong\u003e) is a high-performance ASE2B control module specifically engineered for ABB’s Medium Voltage (MV) AC drive family. This assembly, which includes the processor unit and integrated protective housing, serves as a core computational and interface component within the ACS 2000 and ACS 6000 drive systems. It is responsible for executing complex motor control algorithms, managing high-speed digital signal processing, and facilitating real-time communication between the drive's power electronics and the upper-level control architecture. The \"BE101\" designation indicates a specific hardware revision optimized for industrial and special-purpose medium voltage applications, ensuring stable regulation of high-power motor dynamics in demanding environments such as mining, water treatment, and heavy manufacturing.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUD C920 BE101\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3BHE034863R0001\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eASE2B Control Module with Housing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eACS 2000 \/ ACS 6000 Medium Voltage Drives\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial and Special Purpose MV Drives\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (Net Weight)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85049099\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSwitzerland (CH)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eASE2B Digital Control Platform\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eWhen procuring replacements for Medium Voltage drives, it is critical to verify both the Product ID and the Type Designation to ensure firmware and backplane compatibility.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct ID:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3BHE034863R0001\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eABB Type Designation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUD C920 BE101\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eASE2B WITH HOUSIN (Housing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Order Quantity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 piece\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003ch3\u003eElectrostatic Discharge (ESD) Protection\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUD C920 BE101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtains highly sensitive CMOS components. Maintenance personnel must utilize a grounded ESD wrist strap and an anti-static mat during installation or replacement.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-58 citation-end-58\"\u003eDo not touch the gold edge connectors or surface-mount components directly, as static discharge can cause immediate or latent hardware failure within the ACS 2000\/ACS 6000 control rack.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eModule Seating and Housing Integrity\u003c\/h3\u003e\n\u003cp\u003eThe module is supplied with an integrated industrial housing designed to provide mechanical stability and electromagnetic shielding. When installing the unit into the drive’s control section, ensure the module is fully seated in the backplane connectors before tightening any retaining screws. Inspect the housing for structural damage; any compromise in the shielding could lead to signal interference in high-power switching environments.\u003c\/p\u003e\n\u003ch3\u003eLifecycle and Firmware Synchronicity\u003c\/h3\u003e\n\u003cp\u003eMedium Voltage drives typically require synchronized firmware versions across all control boards. Before commissioning a new\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3BHE034863R0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule, verify that the loaded firmware matches the existing drive parameters and the versions used by peripheral boards (such as the AMC or interface cards). Mismatched firmware can result in \"Control Communication\" faults or unpredictable motor behavior during startup.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the UD C920 BE101 interchangeable between the ACS 2000 and ACS 6000?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe hardware platform is compatible with both series; however, the application software and parameter sets are specific to each drive type. The module must be correctly configured for the specific MV drive architecture in which it is installed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this part include the internal processor board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3BHE034863R0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a complete assembly consisting of the ASE2B processor board pre-installed within its standard protective metal housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary indicators of a faulty UD C920 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTypical failure symptoms include \"Controller Fault\" alarms on the drive's CDP control panel, loss of communication with the DCS via the fieldbus, or failure of the drive to complete its self-test sequence upon power-up.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668629057899,"sku":"3BHE034863R0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-udc920be01-3bhe034863r0001-igct-model-iz3riiy4mwq_86e68e5a-1d38-4092-9a4a-5c4daccb08ba.jpg?v=1765536094","url":"https:\/\/www.plcprotech.com\/products\/abb-ud-c920-be101-3bhe034863r0001-ase2b-drive-control-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}