{"product_id":"abb-xvc904a101-3bhe015412r0101-acs5000-pecint-interface-adapter-board","title":"ABB XVC904A101 3BHE015412R0101 ACS5000 PECINT Interface Adapter Board","description":"\u003ch3\u003eModule Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB \u003cstrong\u003e3BHE015412R0101 XVC904A101 \u003c\/strong\u003eis a specialized heavy-duty industrial interface adapter board engineered to serve as the central Power Electronics Controller Interface Adapter (PECINT) within medium voltage AC drive networks. Operating as the primary signal distribution motherboard inside high-capacity variable speed drive cabinets, this unit bridges ABB's core Power Electronics Controller (PEC) platform with peripheral gate driver circuits and localized terminal infrastructure. Built on a robust PCB Component Variant platform (PCBcmp.Var.), the hardware integrates factory-applied varnish protective coatings to ensure long-term structural data path reliability and prevent localized voltage breakdown within industrial cooling bays.\u003c\/p\u003e\n\u003ch3\u003eFunctional Attributes\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble-Index Nomenclature Coverage:\u003c\/strong\u003e Resolves internal procurement or database conflicts by providing exact matching with both XVC904A101 and continuous XVC904A101:PCBcmp.Var. system notations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Mechanical Frame Integration:\u003c\/strong\u003e Features a robust 18.9 kg assembly profile optimized to withstand high physical stress, low-frequency motor vibrations, and sudden structural shock loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVarnish Protected Circuitry (Var.):\u003c\/strong\u003e Coated with high-grade industrial insulation varnish to seal multi-layer tracking lanes against ambient moisture, conductive dust, and liquid-cooling micro-leaks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeterministic Signal Adaptation (PECINT):\u003c\/strong\u003e Handles high-speed optical-to-electrical signal conversion and level conditioning between the central processing units and the active gate drives.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTarget Deployments\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eACS 5000 Water-Cooled Multi-Drive Cabinets:\u003c\/strong\u003e Installed directly into the core PEC interface rack to coordinate high-current phase switching and real-time loop diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Synchronous Motor Converters:\u003c\/strong\u003e Deployed across mining ventilation setups, high-capacity water pumps, and metal rolling mills to preserve terminal synchronization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarsh Process Environments:\u003c\/strong\u003e Preferred for continuous-duty chemical, extraction, and petrochemical installations requiring absolute signal integrity over long operating lifecycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #2d3748;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n\u003cth style=\"padding: 12px; text-align: left; font-weight: bold; color: #1a365d; border-right: 1px solid #2d3748;\"\u003eEngineering Category\u003c\/th\u003e\n\u003cth style=\"padding: 12px; text-align: left; font-weight: bold; color: #1a365d;\"\u003eHardware Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold; color: #2d3748; border-right: 1px solid #2d3748;\"\u003eOriginal Equipment Manufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eABB Drives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold; color: #2d3748; border-right: 1px solid #2d3748;\"\u003eGlobal Product ID Code\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e3BHE015412R0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold; color: #2d3748; border-right: 1px solid #2d3748;\"\u003eABB Type Designation (Standard)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eXVC904A101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold; color: #2d3748; border-right: 1px solid #2d3748;\"\u003eABB Type Designation (Full Variant)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eXVC904A101:PCBcmp.Var.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold; color: #2d3748; border-right: 1px solid #2d3748;\"\u003eFunctional Description\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003ePower Electronics Controller Interface Adapter (ADAPTER PECINT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold; color: #2d3748; border-right: 1px solid #2d3748;\"\u003eCustoms Harmonization Code\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e85049099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold; color: #2d3748; border-right: 1px solid #2d3748;\"\u003eSuperseded Hardware Reference\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eHE015412R0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold; color: #2d3748; border-right: 1px solid #2d3748;\"\u003eManufacturing Origin\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003eChina (CN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold; color: #2d3748; border-right: 1px solid #2d3748;\"\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e18.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #2d3748;\"\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold; color: #2d3748; border-right: 1px solid #2d3748;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e21.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px; font-weight: bold; color: #2d3748; border-right: 1px solid #2d3748;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px; color: #2d3748;\"\u003e54.0 cm x 48.0 cm x 26.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eField Deployment Protocols\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 16px; margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0; color: #9b2c2c; font-weight: bold;\"\u003eCRITICAL WARNING: MEDIUM VOLTAGE SAFETY MANDATE\u003c\/p\u003e\n\u003cp style=\"margin: 8px 0 0 0; color: #9b2c2c;\"\u003eIsolate all upstream medium-voltage inputs and separate active control power circuits before servicing. High-power water-cooled topologies within ACS 5000 units contain DC-link capacitor banks that preserve fatal energy levels long after primary power disconnection. Test and verify all grounding parameters before handling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003col style=\"list-style: none; padding: 0; margin: 0;\"\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/span\u003e \u003cspan style=\"color: #2d3748; padding-top: 3px;\"\u003eAffix an approved ESD grounding strap before retrieving the massive PECINT motherboard assembly from its protective anti-static shipping materials.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/span\u003e \u003cspan style=\"color: #2d3748; padding-top: 3px;\"\u003eDocument and unplug all optical communication loops, field wire blocks, and main power connectors linking the drive rack to the active adapter interfaces.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/span\u003e \u003cspan style=\"color: #2d3748; padding-top: 3px;\"\u003eSupport the 18.9 kg physical chassis using mechanical lifting tools, loosen the frame anchor screws, and pull the adapter unit steadily out along the cabinet rails.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n\u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/span\u003e \u003cspan style=\"color: #2d3748; padding-top: 3px;\"\u003eSlide the new adapter board into position, seat the bus links fully, and tighten all structural ground fasteners securely before reconnecting the fiber optic communication cables.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668531605867,"sku":"3BHE015412R0101","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-xv-c904-a101-3bhe015412r0101-pcb-board-ibudlkrayen_6178907c-87f7-4613-a7c7-9a68fcc3c426.jpg?v=1765532930","url":"https:\/\/www.plcprotech.com\/products\/abb-xvc904a101-3bhe015412r0101-acs5000-pecint-interface-adapter-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}