{"product_id":"ah64an02p-5c-delta-ah500-series-64-point-digital-output-module","title":"AH64AN02P-5C DELTA AH500 Series 64-Point Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAH64AN02P-5C (AH64AN02P5C)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital output module designed for Delta’s AH500 modular PLC system. This module provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e64 integrated output points\u003c\/strong\u003e, utilizing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePNP (Source)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elogic to drive industrial field devices such as solenoid valves, pilot lights, and interposing relays. Engineered for large-scale automation projects where cabinet space is at a premium, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAH64AN02P-5C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes latched connectors for efficient wiring and supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swapping\u003c\/strong\u003e, allowing the module to be replaced without shutting down the entire system. With built-in diagnostic features like the \"keep-last-value\" function, this module ensures process stability even during CPU transitions or maintenance events.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAH64AN02P-5C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware is optimized for high-reliability signal distribution. Each of the 64 points is rated for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12 to 24 VDC at 0.1 A\u003c\/strong\u003e, making it ideal for driving high-impedance loads and electronic inputs. The unit features 32 individual LED status indicators that can be toggled to monitor all 64 points in banks, providing instant local diagnostics. A critical safety feature is the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKeep-Last-Value function\u003c\/strong\u003e, which allows the user to configure whether outputs should turn off or maintain their current state if the CPU enters a STOP mode or loses communication. For wiring efficiency, the module is designed to interface with external terminal blocks via specialized ribbon cables (DVPACAB series), significantly reducing manual point-to-point wiring time.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAH64AN02P-5C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDELTA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAH500 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePoints\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output (PNP \/ Source)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 to 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 A per point\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 W (Internal) \/ 1.5 W (External)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Block Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLatched Connector (Mil-Spec)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpecial Functions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHot-swapping, Keep-last-value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStatus Indicators\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 LEDs (switchable for 64 points)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the \"Keep-Last-Value\" function?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn specific industrial processes, a sudden loss of control signal can be hazardous (e.g., stopping a cooling fan or closing a critical valve). The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAH64AN02P-5C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows the hardware to \"latch\" the last known state from the CPU, ensuring the field device stays in its safe orientation until manual intervention or a system reboot occurs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. As part of the AH500 architecture, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAH64AN02P-5C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan be removed and replaced while the backplane is powered and the rest of the PLC is running. This is a vital feature for high-availability manufacturing environments where stopping the entire line for a single module replacement is not feasible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I manage the wiring for 64 points with a latched connector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDelta provides pre-assembled cable and terminal block sets (sold separately). For this module, you can use two\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDVPACAB7B10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecables connected to four\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDVPAETB-OR16B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erelay boards, or two\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDVPACAB7A10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecables connected to two\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDVPAETB-OT32A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal blocks. This modular approach ensures a \"plug-and-play\" installation with minimal chance of wiring errors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 0.1 A rating per point is designed for logic signals and small solenoids. If you need to drive high-current loads (e.g., large contactors or motors), always use an external interposing relay board. Exceeding the 0.1 A limit can cause thermal damage to the internal transistor arrays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Power Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure a stable 24 VDC power supply is connected to the external power terminals of the module. Since the module drives 64 points, a voltage drop on the external line can cause erratic behavior of the connected field devices. Use a dedicated industrial-grade power supply for I\/O loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen hot-swapping the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAH64AN02P-5C\u003c\/strong\u003e, ensure the latched connector is fully disengaged before pulling the module from the rack. When inserting the new module, press firmly until the locking tabs click into place to ensure a solid connection to the AH500 high-speed backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Delta Electronics","offers":[{"title":"Default Title","offer_id":53102414627179,"sku":"AH64AN02P-5C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/AH64AN02P-5C-st2zkls0vdc.png?v=1776137208","url":"https:\/\/www.plcprotech.com\/products\/ah64an02p-5c-delta-ah500-series-64-point-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}