{"product_id":"allen-bradley-1492-aifm16-f-3-analog-interface-module","title":"Allen-Bradley 1492-AIFM16-F-3 Analog Interface Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1492-AIFM16-F-3\u003c\/strong\u003e is a fusible 16-channel analog input interface module designed for programmable controller wiring systems. It features integrated 24V DC blown fuse indicators and provides 3 terminals per channel for field-side signal termination. The module incorporates fuse holders for channel protection and DIP switches that allow unused inputs to be jumpered to module common on compatible analog modules.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFusible 16-channel input architecture with 3 terminals per channel.\u003c\/li\u003e\n\u003cli\u003eIntegrated 24V DC blown fuse indicators for rapid diagnostic field status.\u003c\/li\u003e\n\u003cli\u003eConfigurable DIP switches to jumper unused inputs to module common in the closed (ON) position.\u003c\/li\u003e\n\u003cli\u003eEighteen field-side shield terminals jumpered together internally and tied to the D-shell housing.\u003c\/li\u003e\n\u003cli\u003eOn-board fuse holders accommodating $5\\times20\\text{ mm}$ fuses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAnalog signal termination and channel protection for programmable controller I\/O systems.\u003c\/li\u003e\n\u003cli\u003eField sensor wiring integration requiring individual channel fusing and blown fuse indication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1492-AIFM16-F-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Interface Module (AIFM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 Channels (Fusible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals per Channel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC Blown Fuse Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Size Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e5 × 20 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A per input, 12 A per AIFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDIP Switch Settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDefault position: OPEN\/OFF\/NOT jumpered together\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShield Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 field-side terminals jumpered to D-shell housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Ensure field signal voltage and current ratings do not exceed the module specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFusing\u003c\/strong\u003e: Install \u003cspan\u003e5 × 20 mm\u003c\/span\u003efuses into the integrated fuse holders before commissioning; do not exceed 2 A per input channel or 12 A total for the entire module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Source Isolation\u003c\/strong\u003e: Note that fuse clips and blown fuse indicators connect internally to a single power source field-side terminal; all connected inputs must reference the same power source.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnused Inputs Configuration\u003c\/strong\u003e: For analog modules supporting unused input jumpering, set the corresponding DIP switches to the ON position to connect unused inputs to module common.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding\u003c\/strong\u003e: Connect cable shields to the designated field terminals to utilize the internal ground loop to the D-shell housing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695179034987,"sku":"1492-AIFM16-F-3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1492-aifm16-f-3-analog-input-fuse-module-2kmcl3qpiqd_e28faf41-1d86-4ee9-8b89-ac3008fe3d3e.jpg?v=1766114231","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-1492-aifm16-f-3-analog-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}