{"product_id":"allen-bradley-1734-ie2c-point-i-o-2-point-analog-input-module","title":"Allen Bradley 1734-IE2C Point I\/O 2 Point Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003e1734-IE2C\u003c\/strong\u003e is a 2-channel analog current input module designed for integration within the POINT I\/O system architecture. The \u003cstrong\u003e1734-IE2C\u003c\/strong\u003e provides conversion of 4...20 mA and 0...20 mA field signals into 16-bit digital representation for process control systems. The unit sends 6 bytes of input data and fault status information across the backplane to the system controller, operating via DeviceNet, PROFIBUS, ControlNet, or EtherNet\/IP adapters.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 2 single-ended, non-isolated current input channels.\u003c\/li\u003e\n\u003cli\u003eSupports configurable analog input ranges of 4...20 mA and 0...20 mA.\u003c\/li\u003e\n\u003cli\u003eHigh-resolution 16-bit analog-to-digital conversion (0.32 uA\/cnt) using Delta Sigma conversion.\u003c\/li\u003e\n\u003cli\u003eBuilt-in channel status and fault indicators for local diagnostic monitoring.\u003c\/li\u003e\n\u003cli\u003eRemovable Terminal Block (RTB) compatibility allows module replacement without disconnecting field wiring.\u003c\/li\u003e\n\u003cli\u003eIntegrated fault protection up to 28.8V DC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial process automation and monitoring\u003c\/li\u003e\n\u003cli\u003e4...20 mA transmitter signal integration\u003c\/li\u003e\n\u003cli\u003eFactory automation control systems using POINT I\/O architectures\u003c\/li\u003e\n\u003cli\u003eRemote I\/O field signal acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1734-IE2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingapore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56.6 x 12.1 x 77.5 mm (2.23 x 0.48 x 3.05 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 g (1.16 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 single-ended, non-isolated, current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4...20 mA, 0...20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 bits - over 0...21 mA (0.32 uA\/cnt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConversion Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDelta Sigma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance \/ Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAbsolute Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1% Full Scale @ 25 degC (77 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy Drift with Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 ppm\/degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Filter Time Constant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...10,000 ms (default = 0 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Update Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 ms @ Notch = 50 Hz, 100 ms @ Notch = 60 Hz (default), 24 ms @ Notch = 250 Hz, 12 ms @ Notch = 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Rejection Ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Mode Rejection Ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-60 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Overload\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFault protected to 28.8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal DC Power Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC nominal (10...28.8V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal DC Power Supply Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mA @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePOINTBus Current (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mA @ 5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 W @ 28.8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation (Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 BTU\/hr @ 28.8V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50V continuous (tested to withstand 2550V DC for 60 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeyswitch Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Base Screw Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 N-m (7 lb-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25...2.5 mm2 (22...14 AWG) solid or stranded shielded copper wire rated at 75 degC or greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 degC to +55 degC (-4 degF to +131 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eCurrent Input Channel 0 (In 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eCurrent Input Channel 1 (In 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eChassis Ground (Chas Gnd)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eChassis Ground (Chas Gnd)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eCommon (C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eCommon (C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e12\/24V DC Supply (V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e12\/24V DC Supply (V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Base Alignment\u003c\/strong\u003e: Mount the module into a compatible POINT I\/O base assembly (1734-TB, 1734-TBS, 1734-TB3, 1734-TB3S, 1734-TOP, 1734-TOPS, 1734-TOP3, or 1734-TOP3S). Set the keyswitch to position 3 prior to installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Grounding\u003c\/strong\u003e: Install onto a zinc-plated chromate-passivated steel DIN rail to ensure proper chassis grounding. Secure the DIN rail every 200 mm (7.8 in.).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Requirements\u003c\/strong\u003e: Mount in an open-style industrial enclosure rated for Pollution Degree 2 environments and compliant with specific application requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e: Touch a grounded object or wear an approved grounding wrist strap before handling the electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Practices\u003c\/strong\u003e: Use shielded copper wire rated for 75 degC or higher with a maximum insulation thickness of 1.2 mm (3\/64 in.).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ec-UL-us\u003c\/strong\u003e: UL Listed Industrial Control Equipment (UL File E65584); UL Listed for Class I Division 2 Groups A, B, C, D Hazardous Locations (UL File E194810).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUK \/ CE\u003c\/strong\u003e: Compliant with EMC Directive (2014\/30\/EU), LVD (2014\/35\/EU), and RoHS Directive (2011\/65\/EU).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\u003c\/strong\u003e: II 3G Ex ec IIC T4 Gc (DEMKO 04 ATEX 0330347X).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKEX\u003c\/strong\u003e: UL22UKEX2478X.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx\u003c\/strong\u003e: IECEx UL 20.0072X (Ex ec IIC T4 Gc).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCM\u003c\/strong\u003e: Compliant with Australian Radiocommunications Act.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKC\u003c\/strong\u003e: Korean Registration of Broadcasting and Communications Equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC\u003c\/strong\u003e: CNCA-C23-01 Certified Explosion-Proof Electrical Product (2020122309111607).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":53610021552491,"sku":"1734-IE2C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1734-IE2.jpg?v=1785028736","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-1734-ie2c-point-i-o-2-point-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}