{"product_id":"allen-bradley-1746-im16-slc-500-200-240v-ac-digital-input-module","title":"Allen-Bradley 1746-IM16 SLC 500 200\/240V AC Digital Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1746-IM16\u003c\/strong\u003e is a 16-channel digital AC input module designed for integration into \u003cstrong\u003eSLC 500\u003c\/strong\u003e programmable logic controller systems. The module interface processes high-voltage 200\/240V AC discrete signals from field sensing devices and converts them into digital logic levels across the backplane for processing. Equipped with a removable terminal block and electro-optical isolation, the \u003cstrong\u003e1746-IM16\u003c\/strong\u003e ensures reliable signal acquisition in demanding industrial automation applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 digital AC input channels arranged in a single group with internally connected commons.\u003c\/li\u003e\n\u003cli\u003eRemovable terminal block designed for easy maintenance without disturbing field wiring.\u003c\/li\u003e\n\u003cli\u003eElectro-optical isolation protecting control logic circuitry from high-voltage transients on I\/O terminals.\u003c\/li\u003e\n\u003cli\u003eStandard 200\/240V AC signal input rating operating across a wide 170...265V AC voltage range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-voltage AC sensor signal conditioning\u003c\/li\u003e\n\u003cli\u003eIndustrial motor starter state monitoring\u003c\/li\u003e\n\u003cli\u003ePower distribution logic feedback\u003c\/li\u003e\n\u003cli\u003eDiscrete process equipment input interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1746-IM16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMalaysia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200\/240V AC signal input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoints per Common\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170...265V AC @ 47...63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current Consumption (5V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.085 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current Consumption (24V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 mA @ 240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Inrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Inrush Current Duration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Off-State Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Off-State Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Signal Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOn = 35 ms, Off = 45 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500V Electro-optical (I\/O terminals to control logic) \/ Comm Circuits: 500V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...60 degC (32...140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNonoperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...85 degC (-40...185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDisplacement 0.015 in. peak @ 5...57 Hz, Acceleration 2.5 g @ 57...2000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Dissipation (Watts per Point)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.35 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Dissipation (Minimum Watts)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.425 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Dissipation (Total Watts)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.00 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal \/ Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIN 0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Channel 0 (SLC: Decimal 0 \/ PLC: Octal 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIN 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Channel 1 (SLC: Decimal 1 \/ PLC: Octal 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIN 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Channel 2 (SLC: Decimal 2 \/ PLC: Octal 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIN 3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Channel 3 (SLC: Decimal 3 \/ PLC: Octal 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIN 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Channel 4 (SLC: Decimal 4 \/ PLC: Octal 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIN 5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Channel 5 (SLC: Decimal 5 \/ PLC: Octal 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIN 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Channel 6 (SLC: Decimal 6 \/ PLC: Octal 6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIN 7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Channel 7 (SLC: Decimal 7 \/ PLC: Octal 7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIN 8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Channel 8 (SLC: Decimal 8 \/ PLC: Octal 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIN 9\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Channel 9 (SLC: Decimal 9 \/ PLC: Octal 11)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIN 10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Channel 10 (SLC: Decimal 10 \/ PLC: Octal 12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIN 11\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Channel 11 (SLC: Decimal 11 \/ PLC: Octal 13)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIN 12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Channel 12 (SLC: Decimal 12 \/ PLC: Octal 14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIN 13\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Channel 13 (SLC: Decimal 13 \/ PLC: Octal 15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIN 14\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Channel 14 (SLC: Decimal 14 \/ PLC: Octal 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIN 15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Channel 15 (SLC: Decimal 15 \/ PLC: Octal 17)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC COM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Common (Upper) - Internally Connected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC COM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Common (Lower) - Internally Connected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Disconnection:\u003c\/strong\u003e Never install, remove, or wire modules while power is applied to the chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e Install as open-type equipment within an enclosure suitable for specific environmental conditions, rated Pollution Degree 2, Overvoltage Category II, up to 2000 m altitude.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Handle modules using grounded wriststraps and avoid touching circuit components or backplane connectors to prevent electrostatic discharge damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Slot Restrictions:\u003c\/strong\u003e Do not install I\/O modules in Slot 0; the first slot is reserved exclusively for the processor or CPU\/adapter module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Torque \u0026amp; Capacity:\u003c\/strong\u003e Use maximum 2 mm2 (14 AWG) wiring, up to 2 wires per terminal, and tighten terminal screws to a maximum torque of 0.9 Nm (8 lb-in.). Tighten terminal block retaining screws to 0.6 Nm (5.3 lb-in.).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed\u003c\/li\u003e\n\u003cli\u003eCSA Certified\u003c\/li\u003e\n\u003cli\u003eC-UL Approved\u003c\/li\u003e\n\u003cli\u003eCE Compliant\u003c\/li\u003e\n\u003cli\u003eC-Tick\u003c\/li\u003e\n\u003cli\u003eClass I, Division 2 Hazardous Location Groups A, B, C, D\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695181853035,"sku":"1746-IM16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-1746-im16-digital-i-o-modules-xiqrlfl23x4_77cd794c-b9d6-4a22-bbf9-5d90403a44fd.jpg?v=1766114319","url":"https:\/\/www.plcprotech.com\/products\/allen-bradley-1746-im16-slc-500-200-240v-ac-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}